Does DN125 pipe wear a 4 by 120 plus 1 by 70 cable?

Updated on society 2024-06-16
9 answers
  1. Anonymous users2024-02-12

    Yes, it is best to have bends that are open on both sides.

  2. Anonymous users2024-02-11

    Summary. Hello dear, 3*150+1*70 wire, there are three 150mm wires, connected to A, B, C three-phase live wire, one 70mm wire, connected to neutral wire (neutral wire). 150mm wire, diameter about 14mm, 70mm, diameter about 9mm.

    As for the total outer diameter of the cable, there are many varieties, different models, different structural forms, and different voltage levels, and the gap is relatively large. The smallest diameter is about 40mm, the largest diameter is about 70mm, and the general diameter is about 50-60mm. The diameter of the 150 steel pipe is 150mm (mm), so it can wear 2 3x150 1 70.

    Can a 150 iron pipe wear 2 3x150 ten 1 70 cables.

    Hello dear, 3*150+1*70 wire, there are three 150mm wires, connected to A, B, C three-phase live wire, 70mm wire is connected to the front root, connected to the neutral wire (zero line). 150mm wire, the diameter is about 14mm, 70mm, the diameter is about 9mm. As for the total outer diameter of the cable, there are many varieties, different models, different structural forms, and different voltage levels, and the gap is relatively large.

    The smallest Zhinian Annihilation has a diameter of about 40mm, the largest diameter is about 70mm, and the general diameter is about 50-60mm. The diameter of the 150 steel pipe is 150mm (mm), so it can wear 2 3x150 1 70.

    It's not a straight pipe for an elbow.

    Can I wear it with a bend?

    Yes, dear.

    Is it okay for ten 1x70 two cables to be bent.

    It is recommended that you give it a try, because everything depends on the actual situation.

    It's best to go with two tubes.

    If conditions permit, you can go two tubes.

  3. Anonymous users2024-02-10

    4x185+1*120 cable with how big conduit is.

    4x185+1*120 cable socks with a large catheter, a single core has a diameter of more than 30 mm, if three plus a ground wire, it is at least more than 60. Therefore, a single one needs at least 40 or even 50 conduits, and three leaks need at least 90 or 110, I hope it can help you. If my answer is helpful to you, please give a thumbs up (in the lower left corner), I look forward to your like, your efforts are very important to me, and your support is also the motivation for my progress.

    Finally, I wish you good health and a good mood!

  4. Anonymous users2024-02-09

    Summary. Hello dear <>

    4x25 Ten 1 16bttrz cable through 48mm tube. The outer diameter of the 4x25 ten 1 16bttrz cable is about 48 mm, so you need to choose the inner diameter of the pipe greater than 48 mm to ensure that the cable can pass through the pipe. It is generally recommended to choose a pipe with an inner diameter greater than a multiple of the outer diameter of the cable, which can ensure that the cable can move freely within the pipe, and also facilitate future maintenance and replacement.

    Choosing a pipe with an inner diameter greater than 72 mm should suffice.

    4x25 ten 1 16bttrz cable through how big the tube.

    Hello dear <>

    4x25 Ten 1 16bttrz cable through 48mm tube. The outer diameter of the 4x25 16bttrz cable is about 48 mm, and the inner diameter of the pipe needs to be selected to be greater than 48 mm because of the late ridge to ensure that the cable can pass through the pipe. It is generally recommended to choose a pipe with an inner diameter greater than the outer diameter of the base hail cable, which can ensure that the cable can move freely in the pipeline, and it is also convenient for future maintenance and replacement.

    Choosing a pipe with an inner diameter greater than 72 mm should suffice.

    There is no hard and fast rule on the material composition of the conduit, but it can be used as a conduit if it can meet the nominal performance requirements of the standard. Such as cross-linked polyethylene pipe, PE pipe, PVC threading pipe. Therefore, this type of pipe is a type of pipe that is summarized according to the purpose of the lease.

    PVC threading pipes are divided into threaded casing and non-threaded casing according to the connection form, and non-threaded casing is mostly seen; According to the mechanical properties, it is divided into low mechanical stress casing (referred to as light weight), medium mechanical stress casing (referred to as medium size), high mechanical stress casing (referred to as roller field is heavy duty) and ultra-high mechanical stress casing (referred to as super heavy); According to the bending characteristics, it is divided into rigid casing and semi-rigid casing, of which rigid casing is divided into cold-formed rigid casing and non-cold-formed rigid casing. In the construction industry, the common type is non-threaded shouting rigid casing. Have a great day, dear ones.

    I hope mine helps you

  5. Anonymous users2024-02-08

    4x25 ten 1 16bttrz cable through how big the tube.

    Hello dear <>Thank you for your patience and have helped you find the 4x25 Ten 1 16bttrz cable through the 54mm tube! According to the relevant provisions of the national standard GB T 50016 "Code for Engineering Design of Buildings", the laying pipeline of the cable shall meet the following requirements:

    1.The inner diameter of the pipe shall not be less than one of the outer diameter of the cable; 2.When the cable passes through the elbow, the inner diameter of the pipe should not be less than 2 times the outer diameter of the cable.

    Therefore, for a 4x25 ten 1 16bttrz cable, the outer diameter of which is about 27mm, according to the above standard calculation, the minimum required pipe inner diameter should be 27. If the cable needs to pass through an elbow, the minimum required pipe inner diameter should be 27 2 = 54mm. It should be noted that the above standards are only general reference values, and the actual use needs to be comprehensively considered in combination with the specific situation.

    For example, in special cases, it may be necessary to increase the inner diameter of the pipe or take other measures to ensure the safe routing of the cable.

  6. Anonymous users2024-02-07

    3*10+1*6 cable through multi-thick conduit.

    3 * 10 + 1 * 6 cable through how thick conduit: pro 3 * 10 + 1 * 6 cable is the 10 square four-core cable specification is 3 * 10 + 1 * 6, the copper core diameter of the wire with the reference cable diameter (outer diameter) is the calculation process: 1. The radius of the wire is calculated by the formula of finding the circular area

    Number of wires squared = pi (square of the radius of the wire The square of the radius of the wire is: 10 =, and then the root number gives the radius of the wire is, so the wire diameter of the 10 square wire is: 2.

  7. Anonymous users2024-02-06

    YJV-4*240+1*120 cable approximate outer diameter mm, YJV-4*50+1*25 cable approximate outer diameter of the total outer diameter of the steel pipe inner diameter calculation.

    du140mm。

    The specification stipulates that when selecting the cable protection pipe, it is determined according to the diameter of the cable, and the inner diameter of the pipe should not be less than the times of the outer diameter of the cable when the length of the pipe is less than 30 meters and less, and the outer diameter should not be less than the times when it is greater than 30 meters! Of course, the norms are the norms, and the implementation is the implementation! Many places with a high safety factor are subject to good construction!

    As can be seen from the above, if the length of the pipe is less than 30 meters and there are no curves, it is basically okay to use DN150 steel pipes. If it is more than 30 meters, you had better choose the outer diameter of the cable protection pipe according to the requirements of the specification.

  8. Anonymous users2024-02-05

    YJV-4*240+1*120 calculates the outer diameter, calculates the outer diameter. The two cables are side-by-side and about the width and should fit through the DN150 pipe.

  9. Anonymous users2024-02-04

    Theoretical outer diameter of YJV-4*240+1*120:;

    Theoretical outer diameter of YJV-4*50+1*25:

Related questions
13 answers2024-06-16

If you don't choose this kind of water pipe, it is recommended to choose some others, but his words are not very good overall, so it is not recommended.