What happens when the newly bought Gree air conditioner is refrigerated but the drain pipe does not

Updated on society 2024-06-28
11 answers
  1. Anonymous users2024-02-12

    Air humidityIf enough, it will drip water, and if the humidity is not enough, it will not drip water.

    Reasons why the inner machine does not drip water:

    1. If the indoor environment is too dry, it may not drip water, which is a normal phenomenon.

    2. Lack of fluorine, evaporator.

    If the temperature is too high, there will be no condensation.

    There is no drainage.

    3. The temperature of the evaporator is too cold, the fins are frozen, which affects the flow of air and the air volume becomes smaller.

    Causes of condensation.

    When the air conditioner is cooling, the gas freon in the outdoor main engine.

    It is pressurized by the compressor and gasified through the capillary tube into the evaporator of the indoor unit, and the temperature of the indoor unit evaporator is reduced by the principle of liquid gasification and heat absorption, and the fan of the indoor unit is reincarnated to achieve the purpose of cooling the indoor air through the evaporator.

    In this process, because the temperature of the indoor unit is too low, there is a large amount of water vapor in the air through the indoor unit, and when the water vapor touches the evaporator with a low temperature of the indoor unit, condensate is generated.

  2. Anonymous users2024-02-11

    It should be because the outdoor ambient temperature is low and the indoor air is dry.

    Under normal circumstances, if the air conditioner has good cooling performance, but the drain pipe does not drain water, it may also be that the drain pipe is damaged or dented during installation, resulting in blockage and inability to drain water, which will lead to water leakage of the indoor unit or connecting pipe. Or it is caused by the leakage of refrigerant during the installation of the air conditioner.

    It is recommended to contact the dealer or after-sales service for maintenance and troubleshooting.

  3. Anonymous users2024-02-10

    The sink of the new machine is empty, and it will be discharged only when there is a certain amount of water, if it is high temperature and high humidity in summer, the drainage will be faster, wait patiently and wait to see, as long as the refrigeration is normal and the indoor unit does not overflow, it will be fine.

  4. Anonymous users2024-02-09

    1. It may be because of freon.

    Not enough, commonly known as refrigerant.

    Insufficient. 2. The power supply voltage may be insufficient, which causes the problem. 3. It may be that the power of the air conditioner is not enough.

    4. It may be that the water outlet is blocked. 5. It may be that the filter of the air conditioner has too much dust causing the problem. Suggested Treatment:

    1. The phenomenon that the air conditioning drain pipe does not produce water or refrigerate, or it may be due to too much dust on the filter screen, you can disassemble and clean it yourself or use a special filter cleaning agent to spray it for cleaning. 2. If the air conditioner is exposed to the outdoors for a long time, it will be easy to absorb dust and some debris, and if it is not treated, it will affect the heat dissipation performance of the machine, resulting in the deterioration of the refrigeration effect of the air conditioner. The indoor unit is related to health, if it is not cleaned for a long time, it will breed a lot of bacteria and pollute the air.

    3. If the ventilation pipe of the air conditioner is installed for a long time, it will cause the air conditioner drain pipe to be out of water and not refrigerated.

    Try to keep the air conditioning duct as short as possible. 4. If it is because of the lack of freon, you can contact a professional air conditioner maintenance person to add it, and the air conditioner that has been purchased for many years generally needs to be added.

  5. Anonymous users2024-02-08

    In our daily life, every household has installed air conditioning, and the problem solutions are different according to different models of air conditioners, so what is the problem of air conditioning refrigeration not draining? Today, I will talk about this problem, I hope it can help you, and interested friends can follow along to find out.

    1. What is the problem of air conditioning refrigeration not draining.

    1. When the air conditioner does not drain when it is refrigerated, we first test whether the external unit of the air conditioner does not drain water, or the indoor unit of the air conditioner does not drain the water, if the outdoor unit does not drain the water, it is a normal phenomenon, and the drainage is an abnormal phenomenon, if the indoor unit does not drain, it means that the air conditioner is abnormal.

    2. When the air conditioner is turned on in summer, the indoor machine blows cold air, and the outdoor unit blows hot air, which transports the indoor hot air to the outdoors, so as to emit it in the outdoor air. At this time, if the indoor unit does not drain water, then we need to check whether the weathering in the middle of the water pipe of the indoor unit is broken, and whether the flowing water of the external connected water pipe is the phenomenon of flowing water along the bridge deck, and whether the indoor humidity water output is relatively small, which may cause the indoor unit of the air conditioner to not produce water.

    3. In addition, there is also a possibility that the water pipe of the indoor unit of the air conditioner is blocked, if the water pipe is blocked, then the water from the mainland will not be discharged from the indoor unit.

    4. The indoor unit does not drain the water, it may also be that there is a problem with the motherboard extension, capacitors, etc., we had better ask professional personnel to come to the door step by step to check what problems have occurred in the middle, before that, you can take out the indoor filter to check whether there is a serious chance of dust, if there is a serious dust accumulation, we will clean it up first, check whether the drainage is normal, if the drainage is normal, we will seek the help of professionals.

    The above is a summary of the relevant content and information about what is going on with air conditioning and refrigeration, and I hope it can help you. If you have any other questions, you can leave a message at the bottom of the platform, and we will solve the problem for you in time. Finally, if you have any questions about home furnishing and home decoration, you can pay more attention to Qeeka Home.

  6. Anonymous users2024-02-07

    When the air conditioner is cooling, the water does not come out depends on the humidity of the indoor air. If the indoor air is drier, there will be no water. Especially in the northern region, the air is dry all year round, so the air conditioner generally rarely discharges water.

    As long as there is no water leakage in the room and the cooling effect is good, it is normal, and there is no need to worry about it at all.

    When the air conditioner is running in refrigeration mode, the surface temperature of the heat exchanger of the indoor unit is very low, and the water vapor in the indoor air condenses into water on the surface of the heat exchanger, and the water flows into the water tray and is discharged to the outside along the condensate drain pipe. When there is no water in the water tray in the indoor unit of the air conditioner before the air conditioner is used, or the indoor air humidity is low, the discharge of the condensate drain pipe of the air conditioner will be small or even not drained, which is normal. Only when the condensate in the tray has accumulated to a certain extent will it begin to drain out.

  7. Anonymous users2024-02-06

    First of all, check whether the drain pipe is lower than the indoor unit, you can use a cup to fill some water, pour it into the sink of the indoor unit, and see if there is any water flowing out from the outside, if there is, it means that the installation is normal, if there is no even the indoor unit dripping and leaking, that means that the indoor unit is too low, and the installation angle needs to be adjusted. If the installation is normal, but there is still no water flowing out, it is possible that the room is too dry or the water in the sink is not full.

  8. Anonymous users2024-02-05

    The air conditioner is refrigerated but no condensate is discharged, as long as there is no water leakage from the internal unit, there is no problem, it may be that there is no condensate from the internal unit.

  9. Anonymous users2024-02-04

    Hello: 1, the condensate is [Moisture in the air] condensed.

    2. IndoorsHigh humidity] (e.g. dog days or rainy days).MassivelyCondensate flows out. When the air is drier, [CondensateIt's not much, and when the water tray is full, the condensate will flow out.

  10. Anonymous users2024-02-03

    1.Freon is not enough (commonly known as "refrigerant" is not enough), generally appearing in the old air conditioner that has been used for three to four years. The air conditioner did not completely stop cooling, but the effect of cooling decreased.

    This is because old air conditioners use freon as a refrigerant, which will volatilize after long-term use.

    2.The power supply voltage is not enough, and the normal starting voltage of the air conditioner is 220V+-10%. In China's power supply system with a phase voltage of 220V and a line voltage of 380V, almost all compressors above 200V can be started.

    At 180V or more, 70-80% can be started, and at 160V or more, only a few can be started. I've done it myself. Below 160V there is almost no possibility of starting.

    3.The power of air conditioning is not enough, the general selection principle is: 150-250w square meters for cooling, 250-350w square meters for heating, in addition to the need to comprehensively consider factors such as space height, level orientation, sealing performance and residential population.

  11. Anonymous users2024-02-02

    It was an abnormal malfunction of the air conditioner.

    It is a reasonable phenomenon that the condensate drain pipe does not produce water when the refrigeration operation of the air conditioner is not normal.

    The key here is to find out the reasons why the air conditioner cannot be cooled normally and find the corresponding solutions.

    If you can't handle it yourself, you should temporarily stop using the power of the air conditioning unit and report to the product manufacturer for after-sales repair, so that the maintenance personnel can check and repair.

Related questions
18 answers2024-06-28

Gree air conditioner. Reasons for not refrigerating: First, it may be that the power of the air conditioner is not enough. >>>More

6 answers2024-06-28

Gree air conditioner heating mode is not.

The causes and solutions of heating are as follows: >>>More

18 answers2024-06-28

If the air conditioner does not drip water, the cooling effect may not be good, or it is not cooled, and the moisture in the air cannot condense. >>>More

8 answers2024-06-28

- Is the air conditioner malfunctioning? With my 7 years of experience in repairing air conditioners, I will tell you how to solve these faults, which should save you a lot of detours. >>>More

16 answers2024-06-28

The reason why the air conditioner is making a lot of heating noise is most likely due to the following two situations: >>>More