In this case, it is recommended to flare the hole on the outdoor side downwards until there is a slope in the inner and outer wall holes, if the connecting pipe goes up after the wall, the connecting pipe should be coiled down at a U-shaped angle and then coiled upward, which is called a backwater bend, to avoid rainwater or condensation flowing into the room along the connecting pipe.
After the flaring, the wall hole is plugged with a leak plug or something like that. Remember to keep the connecting pipe out of the wall is high inside and low outside.
-
Find an air conditioner installer to help you drill a hole again. Then lean it outdoors so that there is no leakage indoors.
-
It is normal for the water to flow out and flow inward, so change the hole again so that the water can flow out.
-
Jinan, September 2, CCTV News (Reporter Jia Xiaolin) From 0:00 to 24:00 on September 1, 2022, Shandong Province reported 3 new local confirmed cases, including 2 cases in Jinan, 1 case is a person from outside the province who entered Lu, which is a key personnel screening and detection, and 1 case is a close contact and is detected in a centralized isolation point; 1 case in Qingdao, a person who returned to Lu from outside the province, was detected in a centralized isolation point. There were 53 new local asymptomatic infections, including 47 cases in Jining, 43 cases were detected in centralized isolation points (including 1 case of people returning to Lu from outside the province) and 4 cases were detected by screening of key personnel; 2 cases in Jinan, all of which were detected in centralized isolation points (including 1 case of people entering Lu from outside the province); 2 cases in Heze, all of which were detected in centralized isolation points; 1 case in Zaozhuang, which was detected in a centralized isolation point; 1 case in Liaocheng is a close contact of people returning to Lu from outside the province, and it was detected in a centralized isolation point. There were no new imported confirmed cases.
There were 3 new cases of asymptomatic infections imported from abroad, including 2 cases in Jinan, imported from Russia and imported from Germany; 1 case in Heze, imported from Kazakhstan.
-
The solution to the leakage of the round hole at the bottom of the air conditioner is as follows:
If the round hole at the bottom of the air conditioner is blocked, the condensate cannot be discharged normally and will leak out. The solution is to rinse the round hole at the bottom of the air conditioner with clean water to remove the blockage. If the round hole at the bottom of the air conditioner is damaged, if the hole at the bottom of the air conditioner is damaged, the condensate will also leak out.
The solution is to replace the round hole at the bottom of the air conditioner.
If the air conditioner is overloaded, the heat dissipation efficiency of the condenser will be reduced, resulting in an increase in the temperature of the condensate and eventually leaking out. The solution is to reduce the load on the air conditioner or replace it with a larger one. If the filter screen of the air conditioner is blocked, its air circulation volume will decrease, resulting in an increase in the temperature of the condensate and eventually leaking out, the solution is to clean the filter screen.
Common problems with air conditioning:
The evaporator inside the air conditioner is frosty, and the evaporator inside the air conditioner is responsible for absorbing the moisture in the room and converting it into water droplets. If the evaporator inside the air conditioner is frosty, the water droplets cannot be discharged normally, and will leak into the round hole at the bottom of the external unit.
The water tank inside the air conditioner is overflowing, and the water tank inside the air conditioner is responsible for collecting the water droplets and discharging the water droplets through the water pipe. If the water tank inside the air conditioner is overflowing, the water droplets will leak into the round hole at the bottom of the external unit, you can check whether the water tank is damaged, if so, please replace the water tank in time. The condensate in the air conditioning duct will flow into the round hole at the bottom of the air conditioner unit, if the pipe leaks, the condensate will leak out, check the air conditioning duct, find out the leakage point and repair it.
-
The reason may be that the installation of the air conditioner drain pipe is not in the right place, and it is a rainy weather outside, and the rain seeps in from the pipe, so the air conditioner can be reinstalled to solve the problem; The reason may be that the hole gap of the air conditioner is too large, which can be solved by plugging the hole with thermal insulation material; The reason may be that the air conditioner hole is not closed with expanded foam glue after installation, and you can buy foam glue for sealing work by yourself. 1. If the leakage effect of the drainage pipe is not good, the installation location is not suitable for drainage, and the height of the pipeline needs to be adjusted. In addition, it may be that the drainage pipe at the air conditioning hole is too close to each other, resulting in the condensate flowing from the air conditioning hole to the room during drainage, and it is necessary to purchase a drainage hose and connect it to the original drainage pipe, so that the condensate can be discharged outdoors normally.
2. If the hole diameter of the air conditioner is large, then the rainwater will blow from the gap to the room in outdoor rain and windy weather, and it needs to be filled with insulation materials to solve the problem of rain seepage. 3. After the installation of the drainage pipes of the air conditioner, the installation master will use the fixing tape to fill and reinforce the work, if you do not do this work, you can buy expansion foam glue by yourself, first clean up the stones, debris, dust and other things at the air conditioning holes, and then reconcile the expansion foam glue, apply it to the gaps, and wait for it to dry to play an effective role.
-
This phenomenon is not a problem with the air conditioner, but a normal phenomenon. If it has an impact on your life, you can directly install a finger with a smooth water joint at the location of this small hole. Connect a water hose at the end of the downstream connection.
Through this pipe, you can keep the condensate in it where you want it to flow.
Because some of the pipelines inside the main engine are also low-temperature, condensate will be generated on the surface of the pipeline, and the external machine absorbs heat during heating, and the condensate produced is from the bottom.
Department discharge. The amount of water is directly proportional to the air humidity and the heat conversion effect of the air conditioner, and the opposite is true when cooling, and the water is drained by the drainage pipe.
When the air conditioner is refrigerated in summer, due to the low surface temperature of the evaporator of the indoor unit, the moisture and water in the air conditioner condense on the surface of the evaporator of the indoor unit of the air conditioner, and gather more.
After that, water is formed, and the resulting condensate is drained away along the pipeline.
In the same way, when the air conditioner is heating, the air conditioner is heating inside, the outdoor unit is cooling, and the temperature of the outdoor unit is low, and it is also absorbing the moisture in the outdoor air, but it is average.
The outdoor temperature is relatively low during heating, and the surface temperature of the condenser is also lower than 0 degrees, and the moisture in the air will freeze or frost after condensing on the surface of the cold condenser.
As time goes by, more and more knots, so that the heating effect of the air conditioner is getting worse and worse, and when the ice freezes to a certain extent, the air conditioner starts the defrosting process to provide the air conditioner.
After the heating effect, the ice melts and turns into water, which is often referred to as the "leakage" of the outdoor unit of the air conditioner.
-
Install water outlets and water pipes to drain water.
-
If the bottom of the heating machine is leaking, it would be good to install the water outlet and water pipe.
-
1.Clean the air conditioner holes: First of all, you need to clean the air conditioner holes and clean the dust and dirt around the air conditioner holes so as not to affect the normal drainage of the air conditioner.
2.Check the drains: Drains can become clogged, preventing water from draining properly. Pipes can be cleaned with a professional drain cleaner or with steel wire.
3.Replace the drain pipes: If the drain is old or damaged, you need to replace the drain with a new one.
4.Adjust the installation position of the air conditioner: If the installation position of the air conditioner is not suitable, it may lead to poor drainage, and the installation position of the air raid guess needs to be readjusted.
5.Replace the internal parts of the air conditioner: If the internal parts of the air conditioner are damaged or deteriorated, it may lead to water leakage problems, and it is necessary to replace the parts that should be used by the air conditioner.
6.Ask a professional to repair: If the above methods cannot solve the problem, it is recommended to ask a professional air conditioner maintenance personnel to repair and repair.
In fact, the core temperature is higher than the surface temperature. It takes millions of years for light to travel from the inner core of the sun to the surface of the sun. This is because of the action of gravity. >>>More
Midea air conditioner outdoor unit has wires, power supplies, live wires, neutral wires, fan wires or ground wires, if one of them has a ground wire, it is easy to distinguish the ground wire. Then it's easy to find. There should be thick and fine roots. >>>More
It can be used, but the effect is not necessarily optimal. Because the specific design of each manufacturer is not exactly the same. It is difficult to match the internal and external units completely. After all, the standard is independent of each manufacturer, and if there are some problems, it is difficult to repair them after sales.
The button of the inner circulation and the outer circulation of the Wickla refrigeration and air conditioner is a setting of the internal circulation and the external circulation that need to be set on one of its operation passwords, and the specifications are different, which also needs to be paid special attention to.
If it doesn't run, the water temperature is high if you don't turn on the air conditioner, because the electronic fan doesn't run and can't dissipate the engine, when you turn on the air conditioner, the cooling fan will not stop running, so the engine can dissipate heat and the water temperature will not be high. But when you don't turn on the air conditioner, the fan turns again when the water temperature is high, and then stops again when the water temperature is normal. Specifically, there are the following aspects: first, you need to check whether the water tank is not well dissipated and blocked, or the fan is not running, or there is a problem with the water temperature sensor. >>>More