Generator sets regardless of gasoline or diesel should be reserved in the room, can not be used in a confined space, do a good job of ventilation, temperature, space requirements, it is also safe to put indoors!
-
The most important thing is to connect the generator exhaust gas to an exhaust pipe and discharge it to the outside, if it is not too noisy indoors, there is no problem with others, and it is okay not to overload and operate illegally.
-
1. Occasions of use: When the gasoline generator is in use, it should be safe outdoors or in a well-ventilated place in the machine room, and should not be close to doors, windows and vents to avoid carbon monoxide entering the room. 2. Storage and use of fuel: generator fuel should be stored in a special warehouse.
-
Gasoline Generator Safety Precautions:
The exhaust gas of the generator is toxic, and it should not be used in a closed place, so please use it in a well-ventilated place.
When operating or moving, please keep the generator upright. The tilt of the generator can cause fuel leakage and create a hazard.
Keep this generator out of reach of passers-by and children.
Never place any combustible materials near the exhaust port while the generator is running.
The distance between the generator and the building or other installation should be at least 1 metre.
Before the generator is used, the ground wire must be connected, and the ground wire must be a soft wire of more than 4mm2.
Do not use the generator in rain or snow, and add rain protection and ventilation measures when necessary.
Shanghai Oubao Industry Li Zhixin escorts your safety!
-
Summary. Dear, the main hazards of generator and gasoline are as follows
1.Diesel vehicles with gasoline will cause abnormal engine idling, white gas from the exhaust pipe, and long-term use will cause the engine to be scrapped.
2.Although the diesel generator can still start and run with gasoline, the engine is very inefficient.
3.You only need to clean the fuel tank, replace the diesel and continue to use it, no special treatment is required, but you can't use gasoline for a long time!
Gasoline in the generator room is the main hazard.
Dear, the main hazards of the power generation beam to let the machine gasoline are as follows: 1Diesel vehicles with gasoline will cause the engine to idle and the smoke pipe will emit white gas, and long-term use will lead to the scrapping of the engine.
2.Although the diesel generator can still start and run with gasoline, the engine is very inefficient. 3.
You only need to clean the fuel tank, replace the diesel and continue to use it, no special treatment is required, but you can't use gasoline for a long time!
Kiss <>
The exhaust of gasoline generator sets has a great impact on Oh:1It is toxic, and its exhaust can lead to coma and even death in a short period of time. 2.When using, please use the hand hall banquet in a well-ventilated place, and do not use gasoline generator sets in closed places.
-
1. Corresponding measures need to be taken for the anti-virus channel set up between the diesel generator world key room and the control room.
2 First of all, it is necessary to ensure that the ventilation equipment of the anti-virus passage is unobstructed and effective, and regular inspection and maintenance should be carried out to ensure air circulation and timely removal of harmful gases.
3 In addition, the anti-virus channel should be equipped with emergency communication equipment, so that the staff can contact the outside world in time to assist in the rescue in the event of an unexpected situation.
4 At the same time, the sealing performance of the anti-gas passage door is also very important, and the sealing performance of the door is required to be good, which can reduce the entry of harmful gases into the passage and ensure the safety of staff.
5 Finally, regular drills should be conducted for the anti-virus channel to improve the ability of employees to respond to emergencies and ensure the safety of the diesel generator room and the control room.
-
Summary. 1) The leaking fuel of each pipe of the generator set fuselage is accumulated for a long time, and it is easy to ignite under continuous high temperature.
2) The quality of high-pressure oil pipes and oil pipe parts is not good, which can cause fuel to be injected outward to the continuous high temperature turbocharger or smoke exhaust pipe.
3) Ignition caused by wear, short-circuit faults or loose wiring of electrical wiring, which may ignite continuous high-temperature atomized fuel.
4) The intake valve, exhaust valve and fuel injection angle of the diesel engine are not well adjusted, and the joint between the cylinder head and the fuselage or the smoke exhaust pipe is not tight, which can cause continuous high temperature and high pressure fuel can not be fully burned in the cylinder, and the joint part is sprayed out for combustion and fire. Fire prevention measures and suggestions for diesel generator sets.
1) When dealing with diesel engine failure, it is necessary to put cotton yarn on the dripping place, and wipe the residual oil on the fuselage in time to eliminate oil seepage and oil leakage;
2) Dissolve and inspect the smoke exhaust pipe protective cover every month, clean up the residual oil stains, and make records;
3) During the maintenance of the unit, the gasket of the exhaust pipe and cylinder head should be updated with 121 gasket, and the maintenance process should be strictly adhered to to achieve the required torque;
4) Carry out the renovation of the protective cover of the smoke exhaust pipe, and the materials are made of stainless steel inside and outside, and the insulation material in the middle is selected to avoid oil seepage accumulation and convenient cleaning; 5) Regular maintenance and adjustment.
Diesel generator room safety hazards.
1) The leaking fuel of each pipe of the generator set fuselage is accumulated for a long time, and it is easy to ignite under continuous high temperature. (2) The quality of high-pressure oil pipes and oil pipe parts is not good, which can cause fuel to be injected outward to the continuous high temperature turbocharger or smoke exhaust pipe. 3) Ignition caused by wear, short-circuit faults or loose wiring of electrical wiring, which may ignite continuous high-temperature atomized fuel.
4) The intake valve, exhaust valve and fuel injection angle of the diesel engine are not well adjusted, and the joint between the cylinder head and the fuselage or the smoke exhaust pipe is not tight, which can cause continuous high temperature and high pressure fuel can not be fully burned in the cylinder, and the joint part is sprayed out for combustion and fire. Fire prevention measures and suggestions for diesel power generation Xianmingdan unit (1) When dealing with diesel engine failure, it is necessary to put cotton yarn at the oil dripping place, and wipe the residual oil on the fuselage in time to eliminate oil seepage and oil leakage; 2) Dissolve and inspect the smoke exhaust pipe protective cover every month, clean up the residual oil stains, and make records; (3) During the maintenance of the unit, the gasket of the exhaust pipe and the cylinder head should be updated with 121 gasket, and the maintenance process should be strictly adhered to, so as to achieve the required twisting of the limb moment; 4) Carry out the renovation of the protective cover of the smoke exhaust pipe, and the materials are made of stainless steel inside and outside, and the insulation material in the middle is selected to avoid oil seepage accumulation and convenient cleaning; 5) Regular maintenance and adjustment.
5) Regularly maintain and adjust the valve and fuel injection attitude to meet the standard value; (6) Improve the inspection of the main engine room, regularly inspect the application supervision of the fire alarm system and check it on time; (7) Avoid problems that violate the operation process, such as not unloading and shutting down, not slacking off after starting, such as running at a wide speed and supplying power immediately.
-
The engine room is certainly dangerous:
1. Once the high-speed rotating steam turbine generator set is seriously overspeeded, the shaft may break and disintegrate**, and the steam turbine has been flown out of the plant accident.
2. Once the high-temperature and high-pressure pipeline is blasted, it is no less than a bomb.
3. There is also the possibility of falling from high altitudes, the possibility of high-voltage electric shocks, the possibility of oil system fires, the possibility of high-temperature scalding, and so on.
There must be electricity, which is energized to generate a magnetic field, and then the shaft of the generator is driven by an external force, so that there is magnetic flux in the coil. >>>More
For gasoline generators, generally around, 500kw gasoline generators should not exist. >>>More
Household diesel generators.
Power generation cannot be connected to the grid. Because private power generation equipment needs to apply to the relevant departments if it wants to be connected to the grid, the power supply company will send someone to test and check whether it meets the grid connection requirements. Generally speaking, domestic diesel generators are not eligible for grid connection. >>>More
I have the following books.
Wilson diesel generator set. >>>More
1. For diesel and gasoline generators below 10 kilowatts, what kind of oil has less noise and lower fuel consumption cost? >>>More