Rhinestones. How to punch the air conditioner hole and apply water:
A 24V water pump is used to pump water, pressure the rhinestones are applied to break the walls.
Usually the bottled water is connected to the drill inlet and the bucket is placed in a high position. The good thing is to connect the water inlet pipe to the tap water inlet, and then install a regulating valve at the drill water inlet to control the water intake, don't add too much water.
Water pipes are connected. The tap water is convenient and easy to use.
The water pump used in the fish tank is about 100 yuan.
It's easy to let water in, but it's hard to keep the mud thrown out of the rhinestones from getting dirty in a renovated house.
This is to drill out of the water eye with wood plugging, when using the drill bit filled with water with a rag plugged, do not plug too tight, 1 general 25 walls plus 1 time of water to open up, very easy to use, 1 person to operate.
With a 12-volt small water pump, it can pump 4 meters high, more powerful than the fish tank pump, small in size, install a switch in the drilling water to control the work of the pump at any time, and connect the water jacket in the water distribution drill, which is very easy to use. In the past two years, there is no need to install air conditioners with impact drills.
The hole is opened. Ordinary brick walls can be done in a few minutes, if it is drilled to the cement beam, it will be miserable, and it can be done in half an hour, with steel bars. So now install air conditioners resolutely using rhinestones to punch holes.
-
Water pipes are connected. The tap water is convenient and easy to use.
-
The water pump used in the fish tank is about 100 yuan.
-
Rhinestone slag number air conditioning hole water method:
1. Use a 24-volt water pump to pump water, put pressure on the rhinestones, and break the wall.
2. Connect the barreled water to the water inlet of the drill bit, and Tongqiao puts the bucket in a high position. Connect the water inlet pipe to the water inlet, and then install a regulating valve at the drill water inlet to control the water intake, and do not add too much water.
3. Connect the pipeline with water pipes.
4. Use the water pump used in the fish tank to pump the water in, and try not to let the mud thrown out of the rhinestone get dirty like the wheel head slurry.
5. Plug the hole that drills out of the water with wood, fill the drill bit with water and plug it with a rag, and add water to the 25 walls once to open it.
6. Use a 12-volt small water pump, install a switch to control the work of the pump at any time, and then match the water socket of the water drill.
-
1. Air conditioning drilling does not have to use drills, but special drill bits are used.
2. Most workers will choose to use drills during construction, and they will also paste dustproof and waterproof bags, which can effectively avoid the walls from being dirty, and can be quickly penetrated without bringing a lot of dust, so it is best to use drills for air conditioning drilling.
-
When the masters install the hanging air conditioner or the vertical air conditioner, they first need to punch holes in the wall, and the holes also need to meet certain specifications. What is the best drill to use? Do you have to use rhinestones?
1. Do you have to use rhinestone to punch holes in the air conditioner?
If the air conditioner needs to drill holes, it is not necessary to use a water drill, but it must use a special drill bit. Some people will choose to use percussion drills, but most workers will choose to use rhinestones during construction, and rhinestones will be pasted with dustproof and waterproof bags, which can effectively avoid the wall from being dirty, and can be quickly penetrated, will not bring a lot of dust, for the owner's furniture, floor, etc. can play a protective role, but also can effectively protect the construction personnel, so it is best to use rhinestone for air conditioning drilling.
Second, what are the skills of air conditioner punching.
1. Before the construction of the wall, we first need to check whether it is suitable. Because some walls are installed with water pipes or wires, the masters will consult the layout of the owner's home before construction. At the same time, it is also necessary to pay attention not to damage the load-bearing wall, and not to punch holes in the load-bearing wall, otherwise it will affect the structure of the house.
2. Before using an electric drill, you also need to turn on the cooling water, and after stopping drilling, you need to turn off the cooling water, so that the speed of drilling will be faster, and the amount of water required will be relatively large, which can also effectively protect the drill bit and prolong the service life.
3. In the process of punching, generally speaking, horizontal punching is chosen, but the holes of the punching should be slightly higher indoors, and lower outdoors, with a certain slope, so as to facilitate the discharge of condensate. It also prevents rainwater from backing up into the room during the rainy season.
4. The size of the hole can generally not be less than 50 mm, preferably about 60 mm, and the diameter of some holes should be slightly larger, may reach 70 mm, and the specific should be arranged according to the air conditioning pipe.
I concluded: when the air conditioner is drilling, we need to choose the appropriate drill bit, and under normal circumstances, the effect of using rhinestones will be better. Of course, in the process of drilling, it is also necessary to pay attention to some precautions for drilling.
-
It is to drill holes with a water drill, and to operate:
1. Find a roll of transparent tape of about 5 cm, first paste two strips of tape under the position where you want to punch the hole, about 20 cm, 2, and then under the hole, stick a non-breathable and strong convenience bag, not too small, not too big, 20-30 cm is enough, 3, and then use the tape to make a circle around the hole that needs to be punched to prevent the water of the rhinestone from falling out, first punch the hole out with the rhinestone, and then fill the rhinestone with water, and put a rag of suitable size, The wall of 25 can generally be penetrated at one time, basically about 5 minutes, and the wall of 37 is troublesome, and it is necessary to re-fill and continue to play when it is halfway through, and it is generally 10 minutes to penetrate it, and the time of concrete is a little longer. After punching, just tear off the convenience bag.
-
This is usually drilled with a drill, but if you are afraid of soiling the wall, you can also use an ordinary drill bit to dig, but the efficiency is relatively low, it is better to drill with a drill, I hope it will help you!
-
In the hot summer, air conditioning is an indispensable household appliance in every household. Before the air conditioner is installed, some families do not know what the size of the air conditioner hole is, nor do they know when it is most appropriate to make the air conditioner hole. In fact, the best time is to buy a new house or in the blank house, you must reserve the air conditioning hole in advance, because if the air conditioner is drilled during installation, it will get mud on the wall, and it is difficult to clean it in the end, so what is the size of the air conditioner punch hole?
Generally, the size of the air conditioner punching is 400mm or 600mm, which is to be operated by professional tools and drill bits to complete, that is, rhinestones, rhinestones in the process of punching because of its particularly high speed, people who have not been in contact with rhinestones must not blindly try to punch air conditioning holes for their new houses, it is easy to bury the calendar to themselves, it is best to ask some professional masters to operate.
There is a relatively large drill bit, 1000mm. At home, it is used in the opening of the exhaust duct of the range hood, or in the major office units, all the air conditioning ducts extend from a centralized place to the outdoors, and this will not lead to many holes on the wall and affect the appearance.
It is recommended that you do not try to use rhinestones to do the operation of air conditioning punching, do not borrow rhinestones from friends to carry out punching operations, which is very unsafe, rhinestones in high-speed operation because they are rotating in the wall, in the process of rotation, the gap between the pipe wall of the rhinestone rotor and the size of the air conditioning punching is very small, and it must be kept in a horizontal state.
The most important thing is that some rhinestone switches are designed with a card lock, such as accidentally pressing the lock in the process of air conditioning opening, and the lock switch can not be returned in time when the rhinestone and the wall are not dead, the consequences are unimaginable, so do not operate the rhinestone to punch the air conditioning hole.
You can get it for free
Around 7 a.m., close the doors and windows tightly to prevent all sunlight from entering the room. >>>More
In this case, the main reason is that he will use some chemicals in the production, so when he turns on the air conditioner, the smell of these chemicals will come out, so it is a very normal phenomenon.
Check if there is a voltage input to this fan, if there is, it proves that the fan is broken, if not, check the circuit, relay, temperature switch! >>>More
If you don't leave it on for a long time, it's also a good choice to buy fixed frequency. For a 10 square meter room, a large 1 hp cooling capacity is also sufficient. If I had to choose between Midea and Chigo, I would choose Chigo. After all, Zhigao started as a professional air conditioner.
Panasonic air conditioning is good, but also the main force in the air conditioning market, regardless of technical experience or after-sales, very powerful, the landlord said "Panasonic Yilan air conditioner" should be Panasonic's latest main push one, whether in the refrigeration heat, or in the air purification effect is very powerful, and look at some of the reports said that the press conference site has done on-site testing, since the reporters dare to such a bold test, should be very powerful in air purification.