1.The refrigerant** needs to be collected, no matter what time the air conditioner is moved, the refrigerant in the air conditioner needs to be collected into the outdoor unit before the air conditioner is disassembled. The specific method is as follows, first turn on the air condition, adjust the refrigeration condition, run for about 10 minutes, use a wrench to unscrew the cap on the interface between the liquid pipe and the gas pipe of the outdoor unit, and quickly close the shut-off valve of the high-pressure pipe (thin).
After a while, you can see the condensation outside the pipe, so you should quickly watch the low-pressure pipe (thick) cut-off valve, turn off the air conditioner, unplug the power supply, and tighten the safety cap, so that the refrigerant is completed. For the case of moving the machine in winter, it is also necessary to cover the temperature sensor probe of the indoor unit with a warm towel. 2.
To remove the indoor unit, the indoor unit of the air conditioner needs to be detected next, use a wrench to unscrew the connecting lock nut of the indoor unit, and use a sealed sodium to screw the silk pattern of the connecting joint of the indoor unit. The control line needs to be removed using a cross, pay attention to the order of dismantling, and install it in reverse order. The internal hanging board is very strong, and it takes a little effort to make it.
3.Dismantle the outdoor unit, the outdoor unit must be safely dismantled, because most of you are at high altitude, use tools such as wrenches to dismantle, and the unloading should be paid attention to stability, without vibration or bumps. For the takeover, it needs to be protected, so that dust can not get in.
Installation, to the new environment, you need to install the air conditioner, the order is first the indoor unit, then the outdoor unit, then the thick and thin pipes are connected, the thin pipe gate is opened with the inner corner, and finally the power is connected.
-
Operating tools: outdoor unit, indoor unit, side hungry power cord, refrigerant, pipeline.
1. The connecting pipe connecting the outdoor unit of the air conditioner and the indoor unit and the refrigerant in the indoor unit are all ** into the outdoor unit.
2. Remove the connection between the outdoor unit, the refrigeration pipe and the power cord.
3. Remove the indoor unit, the outdoor unit, and the pipeline connecting the limb mold.
4. After moving to the new location, reinstall and fix the indoor unit.
5. Install the outdoor unit, use a suitable size of pipeline, and connect the indoor unit to the outdoor unit.
6. Add refrigerant to the outdoor unit, and the machine can be turned on and running.
Air-conditioner relocation charges applyAir conditioner relocation is a professional job, no matter what kind of air conditioner brand, you need to charge a certain fee. In fact, the air conditioner relocation is related to many factors, such as the number of horses of the air conditioner, the larger the air conditioner move, the higher the air conditioner move, the general ** will be between 100 and 200 yuan.
Of course, if there are different circumstances, different fees will be charged, but these additional fees are generally about 100 yuan, which needs to be decided according to the situation of the professional air conditioner relocation.
-
1. Under refrigeration: open the covers of the two connecting pipe valves of the outdoor unit with a wrench. With five hexagon wrenches, I put in the thin (high-pressure valve) valve port and close the valve quickly, and after about 20 seconds, I close the thick valve (low pressure) and shut down and cut off the power. In this way, the fluorine is received from the outside machine. In this way, the machine can be disassembled.
Second, there is also an open valve to empty during installation: the details are as follows:
After fixing the inner and outer units, 1To connect the air conditioner well, the main thing is to tighten the connecting pipes of the internal and external units, and pay attention to the connection to prevent refrigerant leakage.
2.Use the hexagon switch to hit the automatic air conditioner to open the high-pressure valve (thin pipe valve) normally, and use the hexagon to resist the fluoride port thimble (the fluoride port is on the low pressure), so that the gas inside can run out, about 10 seconds, not too long, so as not to run too much.
This allows the air inside the line to escape.
4.Then open the valves of high and low pressure, and connect the power cord of the internal and external units.
Note: The connecting pipe is copper, and it cannot be coiled into a dead bend, otherwise it will affect the flow of refrigerant, resulting in the inability to cool and heat.
When dismantling, the fluorine should be collected first, otherwise it will cause the leakage of fluorine.
-
1.Prepare tools and materials: moving tools, screwdrivers, wrenches, electric drills, expansion screws, expansion tubes, wires, cable pipes, sealants, etc.
2.Turn off the power: Before moving the air conditioner, you must turn off the electric sales source to avoid electric shock accidents.
3.Disassemble the air conditioner: Use a screw lifter and a wrench to remove the casing and fixing screws of the air conditioner.
4.Move the air conditioner: Use the mobile tool to move the air conditioner to a new location.
5.Mounting Bracket: Install the air conditioner bracket in the new position, using screws.
6.Install the expansion pipe and expansion screws: Install the expansion pipe and expansion screws on the air conditioner bracket to ensure the stability of the air conditioner.
7.Install the wires and cable pipes: Connect the wires and cable pipes to the air conditioner and thread the wires and cable pipes through the air conditioner bracket.
8.Install sealant: Apply sealant between the aircon bracket and the wall to ensure the airtightness of the aircon.
9.Fix the air conditioner: Fix the air conditioner on the bracket and fix it using screws.
10.Turn on the power: Turn on the power supply and test whether the air conditioner is working properly.
11.Clean the air conditioner: After the installation is complete, clean the filters and inside of the air conditioner to ensure the proper operation of the air conditioner.
-
The air conditioner relocation installation steps, **refrigerant, must collect the refrigerant in the air conditioner into the outdoor unit. Start the air witherer before dismantling, you can set the refrigeration state, wait for the compressor to run for 5 to 10 minutes, after the refrigeration state is normal, the socks contain the protective cap on the interface between the liquid pipe and the gas pipe of the external machine.
Close the cut-off valve of the high-pressure pipe, condensation on the surface of the pipe after l minutes, immediately close the coarse cut-off valve of the low-pressure pipe, shut down quickly, unplug the power plug, tighten the safety cap with a wrench, so far the refrigerant work is completed, and the forced start button on the indoor unit can also be used to start the machine, and observe whether there are other faults in the indoor and outdoor units to avoid trouble after the air conditioner is moved.
The contents of the air conditioner relocation
After dismantling the indoor machine refrigerant**, the indoor unit can be disassembled. Use a wrench to unscrew the lock nut of the indoor unit, and use the prepared sealing sodium to screw the silk pattern of the indoor unit connector, and the refrigerant must collect the refrigerant in the air conditioner into the outdoor unit, and start the air conditioner before dismantling.
The refrigeration state can be set, and the compressor will run for 5 to 10 minutes, after the refrigeration state is normal, unscrew the cap on the interface between the liquid pipe and the gas pipe of the external machine, close the cut-off valve of the high-pressure pipe, and the surface of the pipe will be condensed after l minutes, and immediately close the coarse cut-off valve of the low-pressure pipe, and quickly shut down the machine, unplug the power plug, and tighten the safety cap with a wrench. Avoid the trouble caused by the relocation of the air conditioner.
1. Preliminary preparation: the staff will come to disassemble the machine and bring a complete set of tools and safety equipment. >>>More
1.The refrigerant** needs to be collected, no matter what time the air conditioner is moved, the refrigerant in the air conditioner needs to be collected into the outdoor unit before the air conditioner is disassembled. The specific method is as follows, first turn on the air condition, adjust the refrigeration condition, run for about 10 minutes, use a wrench to unscrew the cap on the interface between the liquid pipe and the gas pipe of the outdoor unit, and quickly close the shut-off valve of the high-pressure pipe (thin). >>>More
Midea air conditioner outdoor unit has wires, power supplies, live wires, neutral wires, fan wires or ground wires, if one of them has a ground wire, it is easy to distinguish the ground wire. Then it's easy to find. There should be thick and fine roots. >>>More
1. Step 1 of removing the indoor unit of the air conditioner, in the lower part of the indoor unit of the air conditioner (that is, the place where the air outlet is located against the wall), about a quarter of the place between the left and right side lines, there is a hook hidden inside to connect the hanging plate of the internal unit and the indoor unit together. 2. Then, in these two positions, use a "figure 7" metal hook to gently "hook" the plastic shell at the bottom of the indoor unit downward (the amplitude is about centimeter or so), and then separate the bottom of the indoor unit from the wall with the other hand. Separate the two "hooks". >>>More
Because the law stipulates in this regard, it is illegal to install an air conditioner to infringe on the spatial interests of others.