There are two factors that need to be considered in terms of bearing capacity: first, the bearing capacity of the pipe pile itself; Second, the bearing capacity of the base soil. The bearing capacity of the pile body of 400*95 pipe pile is normally 800kN, and the foundation soil will be tested for soil exploration.
Pile foundation: Pile foundation refers to a deep foundation composed of a pile and a pile cap (referred to as a cap) connected to the top of the pile or a single pile foundation connected by a column and a pile foundation.
Pile foundation is an ancient type of foundation. The number and arrangement of piles in the pile foundation should be determined according to the superstructure and load situation. The under-column pile foundation can be used with one or a group of piles and arranged in polygons.
The pile foundation under the wall is often arranged in rows, and when the building load is large and the area is small, it should be arranged into a full hall pile. Building pile foundations are usually low-cap pile foundations. High-rise buildings.
Pile foundations are widely used.
-
Shaanxi Province pile driver hose manufacturers direct sales of three-meter four-layer steel wire, four-meter four-layer steel wire**029-65656599
-
Brother, tell you, in the 10G409 prestressed concrete pipe pile standard design drawings on pages 44 and 45 of the selection parameters of the pile driver, and the bearing capacity of the pile and the diameter of the pipe pile, and the soil layer is also related, your situation simply consider the bearing capacity, choose the weight of the hammer body of the diesel hammer to the hammer weight, the static pile driver you don't have to consider it, only the bearing capacity of more than 1000 can be used static pile, otherwise it is easy to burst the pile, you take a closer look, brother.
-
What does it mean that a single pile bears a design load of 3000kn?
Dear, I am glad to answer for you: what does it mean that a monopile bears a design load of 3000kn? A: Good morning, kiss! <>
The single pile bears the design load of 3000kN, which means: the bearing capacity of the single pile kn is the compressive capacity that the single pile can bear due to how large the upper load is transferred to the pile. The determination of the characteristic value of the horizontal bearing capacity of a single pile under the same conditions of the unit project shall comply with the following provisions:
1) When the horizontal bearing capacity is controlled according to the strength of the hand in front of the pile, the statistical value of the horizontal critical load is taken as the characteristic value of the hydraulic bearing capacity of the single pile. (2) when the pile is subjected to long-term horizontal load and the state is not allowed to crack, take the times of the horizontal critical load statistical value as the characteristic value of the horizontal bearing capacity of the single pile; (3) When the horizontal bearing capacity of the water limb is controlled according to the allowable horizontal displacement required by the design, the horizontal load corresponding to the horizontal allowable displacement required by the design can be taken as the characteristic value of the horizontal bearing capacity of the single pile, but it should meet the requirements of the anti-cracking design of the relevant specifications. Thank you for your patience. The above is all my reply, if you are satisfied with my service, please give a thumbs up, and I wish you all the best!
Peace and joy!
-
(1) It is the sealing pipe pile to calculate the pile end resistance.
2) It is the open pipe pile to calculate the pile end resistance.
Usually the end of the pipe pile is sealed.
-
Because there is a tip at the end of the pile, it forms a closed whole with the pile. The bearing capacity is not to see the bearing capacity of the pile, but to see how much force the soil layer at the end of the pile can carry, because the bearing capacity of the pile itself is far greater than the design value. So it should be (1).
-
The bearing capacity of a single pile 1800kn is 180 tons. 1800kn is 180000kg, 180000kg = 180t, 1800kn is equal to 180 tons per mu.
-
Summary. What type of pile must be equipped with a single pile bearing capacity of 1500kln? Hello, dear, <>
The bearing capacity of the prestressed pipe pile is the design value, which proves the bearing capacity of the pipe pile, and different specifications are different. It is not the same as the pile pressing parameters when in use. The pile pressing parameters are related to the foundation soil layer, but the maximum pressure cannot be greater than 1500kN.
The engineering pile foundation is designed with high-strength prestressed concrete pipe piles (pile diameter of 500mm, PHC wall thickness of 125mm, AB pipe pile, single pile bearing capacity of 1500kN, I hope to help you!
What type of pile must be equipped with a single pile bearing capacity of 1500kln?
What type of pile must be equipped with a single pile bearing capacity of 1500kln? Hello, dear, <> the bearing capacity of the prestressed pipe pile is the design value, which proves that the bearing capacity of the pipe pile is different for different specifications. It is not the same as the pile pressing parameters when in use.
The number of piles is related to the foundation soil layer, but the maximum pressure cannot be greater than 1500kN. The engineering pile foundation is designed with high-strength prestressed concrete pipe piles (pile diameter of 500mm, PHC wall thickness of 125mm, AB-type pipe pile, and the bearing capacity of a single pile is 1500kN, I hope to help you! Stuffiness.
Hello, dear, <>
The project adopts AB type, I hope it can help you!
With D 400, high strength prestressed (PHC) type A. Can it meet the bearing capacity of 1500kn.
Hello, dear, <>
No, this load capacity is around 1200kN, I hope it can help you!
-
What does it mean that a single pile bears a design load of 3000kn?
Hello, I'm glad to have your question, the single pile bears the design load of 3000kN, which means: the bearing capacity of the single pile kn is the compressive capacity that the single pile can bear due to the upper load transmitted to the pile. The determination of the characteristic value of the hidden load force of the single pile level under the same condition of the unit project shall comply with the following provisions:
1) When the horizontal bearing capacity is controlled according to the strength of the pile, the statistical value of the horizontal critical load is taken as the characteristic value of the hydraulic bearing capacity of the single pile. (2) when the pile is subjected to the long-term horizontal forest hall load and the state is not allowed to crack, take the times of the horizontal critical load statistical value as the characteristic value of the horizontal bearing capacity of the single pile; (3) When the horizontal allowable displacement is controlled according to the design requirements, the horizontal load corresponding to the horizontal allowable displacement required by the design can be taken as the characteristic value of the horizontal bearing capacity of the single pile, but it should meet the requirements of the anti-cracking design of the relevant specifications. Thank you for your patience. The above is my full reply, if you are satisfied with my service, please give a thumbs up, and I wish you all the best!
Peace and joy!
-
The question is not about the bearing capacity of the monopile, but about the load value of the monopile!
1.This has nothing to do with the size of the project; 2.There are many factors that affect the load size of a single pile, and it is impossible to accurately say the height of the building; 3.For monopiles ranging from a dozen to twenty floors, there are often design loads as large as 6000kN.
-
Summary. In response to this problem, what is the highest kn of pile pressing force? The answer is:
According to the total weight of the pile driver of 500 tons, the maximum normal value of the pile pressing force is 500kn. The methods and practical steps to solve this problem are as follows:1
First of all, the total weight of the pile driver is determined, which is the basis for calculating the pile pressing force. 2.Then, according to the total weight of the pile driver, the highest normal value of the pile pressing force is calculated.
Generally speaking, the larger the total weight of the pile driver, the higher the maximum normal value of the pile pressing force. 3.Finally, if the actual pile pressing force is greater than the maximum normal value, measures need to be taken to reduce the pile pressing force to ensure the safe use of the pile driver.
The above is about the total weight of the pile driver of 500 tons, how much is the highest kn of the pile pressing force normal answers and solutions and practice steps.
The total weight of the pile driver is 500 tons, and the maximum pile pressing force is normal.
In response to this problem, what is the highest kn of pile pressing force? The answer is: according to the total weight of the pile driver of 500 tons, the normal value of the maximum height of the pile pressing force is 500kN.
The methods and practical steps to solve this problem are as follows:1First of all, the potato scale should determine the total weight of the pile driver, which is the basis for calculating the pile pressing force.
2.Then, according to the total weight of the pile driver, the highest normal value of the pile pressing force is calculated. Generally speaking, the larger the total weight of the pile driver, the higher the maximum normal value of the pile pressing force.
3.Finally, compare the actual pile pressing force and the highest normal value, if the actual pile pressing force is greater than the maximum and normal value, it is necessary to take measures to reduce the pile pressing force to ensure the safe use of the pile driver. The above is about the total weight of the pile driver of 500 tons, how much is the highest kn of the pile pressing force normal answers and solutions and practice steps.
I'm sorry I don't understand, but can you elaborate on that?
For the total weight of the pile driver of 500 tons, the maximum KN of the pile pressing force is normal, we can determine according to the design specifications of the pile driver. Generally speaking, the pile driving force of the pile driver should be controlled within multiple of the total weight of the pile driver, that is, the maximum normal value of the pile driving force of the 500-ton pile driver is 750kN. In addition, the pile pressing force of the pile driver is also affected by the design specifications of the pile driver, the structure of the pile driver and the use environment of the pile driver.
The design specification of the pile driver is an important reference for the pile driving force of the pile driver, and the structure and use environment of the pile driver will also affect the pile pressing force of the pile driver, such as the unreasonable structural design of the pile driver and the poor use environment of the pile driver, which will lead to the high pile pressing force of the pile driver, thereby affecting the service life of the pile driver. Therefore, when using the pile driver, the structure of the pile driver with mu yard should be reasonably designed according to the design specifications of the pile driver, and the use environment of the pile driver should be paid attention to to ensure that the pile driving force of the pile driver is within the normal range, so as to ensure the service life of the pile driver.
The problem of "floating pile" you mentioned is still relatively common in the construction of hydrostatic pipe piles, and we generally call it pile lifting, and the pile lifting is mainly static pile. >>>More
The depth of the pile in the lower chamber is 500 from the design pile top to the outdoor floor height. Your basement is relatively deep, and it should be excavated first and then piled, so the pile feeding depth is designed to be as high as the top of the pile to the parking surface (raft. >>>More
It's beautiful. I just finished reading it. Although it is a man wearing a woman, it can't be seen at first, but it is slowly seen. >>>More
Engineering piles: piles used in formal projects, most of which are piles for pile foundation projects. Generally, only the integrity test of the pile is done, and the bearing capacity test is no longer done. >>>More
The correct way to stand on the pile**Daquan.