How to wire the meter slowly:1 Find the meter box, first open it. We are now more strictly managed, and there are usually locks.
I don't care how the lock is opened. 2. When you see so many meters, you must first find the one in your house, otherwise you will do good things for others. 4. Whether it is single-phase electricity or two-phase electricity or three-phase electricity, the principle is the same, they flow through the meter like water flow, and the meter records the amount of flow like a counter.
How to make the number less is to reduce the amount of electricity flowing through the meter. 5. The meter is actually an electrical appliance, as long as we use a wire to short-circuit it, then the current flowing through the meter will be less or none, this is our method. The meter will have a live wire connection inlet and a neutral wire connection inlet, as well as a live wire outlet and a neutral wire outlet, we only need to connect a copper wire between the two live wires, so that the meter will be shorted.
6. The meter that is shorted will naturally not go. When doing this, you should be hidden, and you should pay attention to safety.
-
According to your description, this is an act of electricity theft.
Electricity theft is illegal, and no individual or organization may use any means to commit electricity theft.
According to the relevant laws and regulations of our country.
It is stipulated that the power supply enterprises will stop the electricity thieves who are found and can stop the power supply on the spot. The person who steals electricity shall pay the electricity fee according to the amount stolen, and bear the default electricity fee of three times the electricity fee. If the power supply company refuses to bear the responsibility for electricity theft, it will report to the power management department to deal with it in accordance with the law.
If the amount of electricity stolen is relatively large or the circumstances are serious, the power supply enterprise will request the judicial authorities to investigate criminal responsibility in accordance with the law.
We hope you find ours helpful. If you have any other questions, please call the 24-hour power supply service**95598.
-
Horizontal installation. The meter wiring should not make the meter slow, for example, the live wire of the neutral wire will not turn or burn out, and only the horizontal installation will be relatively slow.
-
According to your situation, there should be a problem with the meter, you can use a 1000w incandescent lamp for testing, don't blindly change the meter, light up for an hour, first write down the initial degree of the meter, and then write down another electricity degree after an hour, if it is 1 degree or the difference is very small, then it is not a problem with the meter, you have to check the reason, see if others have used your electricity (others steal electricity), if not, it may be that you have really used so electricity, you need to save electricity, thank you.
-
One of the original intentions of the new meter is to prevent human operation from changing the accuracy of the meter.
-
Yes: Change the connection: Terminate the output on the current coil.
With a corrector: the principle of frequency conversion is used.
Widening the difference method: If the difference is widened, the power factor will be reduced, making the meter go slower.
Objects are used to interfere with voltage or current coils.
All four of these are different ways to make your meter go slower, so just choose one of them.
-
No, it's better to ask them to change it for you, and it's only a few dozen yuan for your own money.
If they don't change it and smash the meter, see if they can change it.
-
Go for a different piece, or add a resistor and you'll be fine.
-
This doesn't seem to be the way to do it, it's a problem with the heart of the watch, and it can't be changed.
-
Use a professional instrument [electric energy meter effectiveness device] to calibrate the meter; modify the pulse constant in the metering program; After disassembling the meter, a copper wire is added to the sampling shunt.
Question: Is a multi-function meter the same?
Ask if there is any way to not split the table.
Ask which method is best and most convenient.
Will the meter go away after asking a question?
Question: Some people say that using magnets can slow down the meter.
-
1. Change the connection method
Connect the output end to the current coil (which is the end of the meter), and when the power is turned on, the meter starts to rotate, and if it rotates forward, plug the plug backwards and the meter is reversed
2. Use a corrector:
1) Ordinary mechanical watch (220V) corrector: the use of frequency conversion principle. The electricity of 50 Haotz is converted into the current of 320 Haotz - 460 Haotz, and the current coil of the meter is reversed through the bidirectional device, which can only make the meter reverse and cannot be stopped.
After receiving the meter, it can be operated on one fire and one zero line.
2) Three-phase meter (380V) corrector: It is to superimpose the voltage of the three phase wires to generate a voltage of nearly 1000 volts, and then rectify, stabilize, sample, and reverse current in the transformer after digital frequency conversion, so that the single-phase, three-phase, and electronic meters in operation do not rotate or rotate slowly % adjustable). After receiving the meter, the three fires and one zero line can be operated.
3. Widening the difference method:
Connect a capacitor or an inductance coil in series on the live wire of the home. The phase difference is widened, and the power factor decreases, which slows down the change in the meter readings.
Note: I am all in principle. In fact, it is not operable, otherwise being fined is a small matter, and being embarrassed is a big thing. Because I don't use much electricity every month.
-
Here's how to make the meter go slower:
1. Modify the pulse constant in the metering program.
2. The professional instrument electric energy meter calibration device is used to calibrate the meter, so that the electronic meter can be adjusted slowly.
3. After disassembling the meter, add a copper wire on the sampling shunt.
4. According to the principle of the watt-hour meter, it can be known that changing the speed of the watt-hour meter, the gear conversion ratio and changing the current, voltage, and phase of the input watt-hour meter can achieve the purpose of making the meter go slower.
5. The simplest way is to use a large magnet with strong magnetic force to place it at the pointer position of the meter, so that its speed can be changed, so that the pointer will go slowly.
6. The most effective way is to connect the live wire at the input end of the meter to the live wire at the output end with a wire, so that the meter will be short-circuited, and the meter will basically not go.
The role of the energy meter:
1. Metering and storage functions.
It can measure the single-way and two-way active and reactive electrical energy during the multi-colored cherry tree planting period; It can complete the measurement and display of current power, demand, power factor and other parameters. Data from at least the previous meter reading cycle can be stored.
2. Monitoring function.
It can monitor the customer's power and high demand, and prevent its electricity theft behavior by analyzing the customer's power load curve.
3. Control function.
Able to implement time period control and load control for customers. The former is used for multi-rate time-of-use billing; The latter refers to receiving remote control instructions through the communication interface or controlling the load through the internal programming of the meter (taking into account the time period and load setting). The electronic electric energy meter with IC card interface can not only complete the prepayment function, but also have the control function of alarm delay and power failure when the purchased power is about to be exhausted.
4. Management function.
The electronic energy meter is connected with the communication network or meter reading system of the power system through the communication interface to realize remote data exchange with the outside world. The customer server with authority in the power network can use the address code of the electric energy meter (generally 12-digit decimal number) to accurately set the completion period, the period rate, the period power limit, the remaining power alarm limit, the representative day, the freezing day, the mode, time and slippage of the demand; Call and view the customer's real-time power; Copy the relevant electricity consumption, and transmit the electric energy metering information to the corresponding departments as needed for system scheduling, electric energy control, electric energy exchange and business billing. <>
-
Summary. Hello, I'm glad to answer for you: Method 1, a professional instrument [electric energy meter effectiveness device] to calibrate the meter, so that the electronic meter can be slowed down.
Method 2: Modify the pulse constant in the metering program.
Method 3: After disassembling the meter, a copper wire is added to the sampling shunt. Steps: 1. Tilt the vertically installed meter by 15°.
2. Open the meter wiring cover, loosen one of the screws of the current wiring card at the top left of the terminal (horizontal clip), (note that there is electricity, please use an insulated screwdriver to operate), the meter at this time is counted when the electricity load is large, and the load hour is not counted. 3. If you are a little more professional, you can open the meter shell and loosen the top wire above or below the center of the rotating disk, which is the best way to use this method with the first method.
Hello, I am inquiring for you here, please wait a while, I will reply to you immediately Hello, I am happy to answer for you: Method 1, professional instrument [electric energy meter effect device] to calibrate the meter, so that the electronic meter can be slowed down. Method 2: Modify the pulse constant in the ear counting program.
Method 3: After disassembling the meter, a copper wire is added to the sampling shunt. Steps: 1. Tilt the vertically installed meter by 15°.
2. Open the wiring cover of the meter, and loosen one of the screws of the current wiring card in the upper left corner of the terminal (horizontal clip), (note that there is electricity, please use an insulated screwdriver to guess the early macro operation), the meter at this time is counted when the electricity load is large, and the load hour is not counted. 3. If you are a little more professional, you can open the meter shell and loosen the top wire of the top wire above the center of the rotating disk or under the opening side, which is the best effect with the first method.
Disconnect all circuits and find the cause one level at a time, preferably in detail. >>>More
One set of power supply test, one set of load test.
There is a screw on the left side of the shell of the table, which is 1cm in diameter, which is used to calibrate the watch, and can be turned clockwise with a flat mouth, it will go slowly, but the slowest can only be less than about one degree of electricity a day, if you want to only go ten kilowatt-hours a month or less, you have to use the second method to steal the beam and change the column, take a 600 rpm meter, that is, turn 600 times to one kilowatt-hour of electricity, the larger the number means that the same electricity will be turned more times, remove the gear combination inside, Change it with the gear combination of your big meter, your big meter must be the kind of 200 rpm, after replacing it, haha, your electricity bill is the original 1 3, rest assured, the parts in the meter are standard parts, it must be worthy of it, but it is to completely remove the meter when doing hands and feet, it is more troublesome, once it is replaced, it is the person from the meter factory who will not find the reason to check, unless he takes the meter back to the tester to measure the number of revolutions, the general electricity bureau does not have this equipment, haha. >>>More
In the case of only using the neutral line, the alternating current cannot form a loop, so it cannot convert the electrical energy into the energy required for the electrical appliance to work, so the meter cannot record the electrical energy consumed by the electrical appliance, that is, the electric meter will not run. >>>More
How to check if the electricity consumption is obviously excessive: >>>More