<> Midea's KFR-35GW BP3DN1Y-TA100 (B1) air conditioner has a P0 fault**, which means that the electronic control board is faulty. In this case, the current power supply voltage of the air conditioner is too low, and you can turn the air conditioner off for a period of time (about 10 minutes) and then turn it back on, or check whether the compressor has a short circuit. If you can't solve it yourself, you can contact the maintenance personnel to come to repair.
Midea's KFR-35GW BP2DN1Y-YA300 (B3) air conditioner has a P0 fault** means that the electronic control board is faulty. In this case, the current power supply voltage of the air conditioner is too low, and you can turn the air conditioner off for a period of time (about 10 minutes) and then turn it back on, or check whether the compressor has a short circuit. If you can't solve it yourself, you can contact the maintenance personnel to come to repair.
Midea's KFR-72LW BP3DN8Y-YB302 (B1) air conditioner has a P0 fault**, which means that the electric control board is faulty. In this case, the current power supply voltage of the air conditioner is too low, and you can turn the air conditioner off for a period of time (about 10 minutes) and then turn it back on, or check whether the compressor has a short circuit. If you can't solve it yourself, you can contact the maintenance personnel to come to repair.
This answer applies to most models of the Midea brand.
-
Summary. There may be several reasons for this:
1. If the current power supply voltage of the air conditioner is too low or the connected voltage is unstable, the module protection of the air conditioner will be triggered, and the air conditioner can be turned off for a period of time before turning it on.
2. There is a short circuit phenomenon in the air conditioning compressor, if the compressor runs for a long time, the compressor line group and the copper pipe will be rubbed, which will lead to damage to the insulation of the compressor connection line group, and the intermittent short circuit between the winding and the ground during the start-up operation, resulting in excessive module current and P0 module protection.
It is recommended that in this case, you can call the 24-hour after-sales service of Midea air conditioner**: 4008899315, if it is still within the warranty period, you can carry out free warranty or replacement, or find professional maintenance personnel to deal with it.
What is the fault of Midea's air conditioner with p0.
Midea P0 fault ** means that the electronic control board is faulty, it is the Midea air conditioner overvoltage protection fault**, once there is a P0 fault** air conditioner will not work normally, the cause may be that the power supply voltage is too low, the connected voltage is unstable, resulting in excessive module current, P0 module protection.
The reasons may be as follows: 1. The current power supply voltage of the air conditioner is too low or the connected voltage is unstable, which will trigger the module protection of the air conditioner, and the air conditioner can be turned off for a period of time before turning it on. 2. There is a short circuit phenomenon in the air conditioning compressor, if the compressor runs for a long time, the compressor line group and the copper pipe will be rubbed, which will lead to damage to the insulation of the compressor connection line group, and the intermittent short circuit between the winding and the ground during the start-up operation, resulting in excessive module current and P0 module protection.
It is recommended that in this case, you can call the 24-hour after-sales service of Midea air conditioner**: 4008899315, if it is still within the warranty period, you can carry out free warranty or replacement, or find professional maintenance personnel to deal with it.
-
Midea's air conditioner appears P0 is: electric control board failure**.
Midea's air conditioner displays P0 for IPM module protection. In this case, it is necessary to observe whether the installation of the whole machine meets the requirements of the installation specification, whether the heat dissipation is good, and whether the system pressure, voltage, and speed of the external fan are normal.
Disconnect the power supply of the whole machine, and after the whole machine is finished, use a multimeter to detect the resistance value of the three-phase winding of the compressor body, and the three-phase resistance value is equal, whether there is phase loss, short circuit and leakage fault. Check the output voltage of the outdoor unit module, and test whether the resistance value of the module P-W, U, V and the resistance value of N-W, U, V of Luwang are normal.
-
Summary. The air conditioner shows that P0 is faulty** It may be that the automatic mode is turned on, the voltage is abnormal, or the indoor coil temperature is too high and the shutdown protection is caused. Here's why and how to fix it:
1. It may be that the automatic mode is turned on:
When the set temperature is close to the room temperature, the machine will stop when the ash set temperature is reached in automatic mode. It creates the illusion of failure when it is turned on and stops, but there is no problem with the actual air conditioner. In this case, it is recommended to switch to other modes.
2. It may be that the electrical voltage is abnormal
When the voltage is unstable, the compressor is overcurrent protected, resulting in a P0 condition. In this case, it is recommended to replace the voltage regulator device or contact the after-sales service for the replacement of the voltage regulator device.
3. It may be that the temperature of the indoor coil is too high, resulting in protective shutdown
When the indoor temperature is 26 degrees Celsius and the outdoor temperature is above 20 degrees, the air conditioner cannot heat normally, which is easy to cause protection. In this case, it is recommended to check whether there is any abnormality in the temperature of the indoor coil first, and if it is abnormal, carry out after-sales maintenance.
4. It may be that the indoor fan is faulty and does not blow the air, and the protection is stopped
When the outdoor fan fails, it will cause frost formation. In this case, it is recommended to defrost and put the indoor unit into the anti-cold air function. If the situation persists, it is recommended to send it to the after-sales service or a third-party professional organization for maintenance.
Midea's air conditioner is turned on for a while p0
Dear, hello, please wait a moment, we have seen your question in Bishan, and we are sorting out the information for you quickly, and we will send your answer to the little master immediately. Thank you for your support, recognize my service, and remember to give a thumbs up<>
<> air conditioner shows P0 fault**, it may be that the automatic mode is turned on, the voltage is abnormal, or the indoor coil temperature is too high and the side bird is shut down for protection. The following are the specific reasons and solutions: 1. It may be that the automatic mode is turned on:
When the set temperature is close to the room temperature, the machine will stop when the ash set temperature is reached in automatic mode. It creates the illusion of failure when it is turned on and stops, but there is no problem with the actual air conditioner. In this case, it is recommended to switch to other modes.
2. It may be that the electric voltage is abnormal: when the voltage is unstable, the compressor will be overcurrent protected, resulting in the situation of P0. In this case, it is recommended to replace the voltage regulator device or contact the after-sales service for the replacement of the voltage regulator device.
3. It may be that the indoor coil temperature is too high, resulting in protective shutdown: when the indoor temperature is 26 degrees and the outdoor temperature is above 20 degrees, the air conditioner cannot heat normally, which is easy to cause protection. In this case, it is recommended to check whether there is any abnormality in the temperature of the indoor coil first, and if it is abnormal, carry out after-sales maintenance.
4. It may be that the failure of the indoor fan causes no blowing and protection shutdown: when the outdoor fan fails, it will cause frost. In this case, it is recommended to defrost and put the indoor sensitive machine into the cold air prevention function as soon as possible.
If the situation still exists, it is recommended to send it to the after-sales service or the third-party professional organization of the first three parties for maintenance.
-
1. The P0 of Midea's air conditioner is: the electronic control board is faulty**.
2. You can call Midea air conditioner 24-hour after-sales service nationwide**: 4008899315.
3. Note: If you can ask for free replacement within 6 years, if you replace the electric control board at your own expense outside 6 years.
-
Boot check that the indoor unit L and N have a 230V power supply voltage output to the outdoors, and there is a DC 2-24V pulse voltage between N and S, so it is judged that the fault is in the outdoor unit. After the first compressor run for 3 minutes, the indoor unit will display P0, and the second compressor will display P0 after 10 minutes.
-
IPM module protection, this is the fault of Midea's inverter**, you are talking about the M4+ inverter, that is the most I have seen, you might as well buy the H4 new refrigerant that is good, Midea's inverter press is either Meizhi or Sanyo has nothing else.
The remote control cancels the timer.
Hello! Faulty air conditioner? I'll tell you how to solve these failures, which should save you a lot of detours. >>>More
<> winter and summer start-up is the same, refrigeration is run like this, heating is opposite, air humidity is high, if the outdoor temperature is as low as zero, the water will become ice, and it is necessary to pay attention to snow removal and ice shoveling on snowy days. At present, most of the air conditioners produced in our country are of T1 climate type. Therefore, when operating under refrigeration conditions in summer, when the outdoor temperature exceeds 43, the air conditioner will not be able to cool normally or the work efficiency will be very low; In winter, when the ambient temperature is lower than minus 7, the air conditioner cannot work normally or the heating efficiency is very low. >>>More
The reason why the air conditioner will automatically turn off as soon as it is turned on: >>>More
1.The BV cable used for the air conditioner is not thin. (If the wire diameter is not enough, the wire will heat up.) Leakage protection of the guide). >>>More
It is normal for the air conditioner to emit air when it is turned on, and it will not be ventilated after a while. >>>More