The Gree air conditioner Xiaojinge sometimes turns on for a few minutes and gets hot

Updated on technology 2024-08-06
5 answers
  1. Anonymous users2024-02-15

    That should be a little golden bean, right? H1 is a defrosting fault. The temperature in your home may be low, and the temperature sensor will automatically activate the defrosting function when it detects that your condenser temperature is too low.

    If it is not too serious, it will generally end within ten minutes, at this time, the internal unit does not work, the external unit continues to work according to the refrigeration mode, and the external fan does not work. Please refer to the following Gree Failure**.

    Fault, protection significance Display** Internal unit indicator light display system high voltage protection e1 running light off 3s flashing 1 time internal machine antifreeze protection e2 running light off 3s flashing 2 times.

    System low voltage protection E3 running light off for 3s flashes 3 times.

    Compressor exhaust protection e4 running light off for 3s flashing 4 times low voltage overcurrent protection e5 running light off for 3s flashing 5 times communication failure e6 running light off for 3s flashing 6 times.

    Mode Conflict: E7 runs the light off for 3s and flashes 7 times.

    Anti-high temperature protection E8 running light off for 3s flashes 8 times.

    Anti-cold wind protection E9 running light off for 3s flashes 9 times.

    Room temperature on, short circuit F1 Refrigeration indicator light off for 3s flashing 1 time inner tube temperature on, short circuit F2 Refrigeration indicator light off for 3s flashing 2 times outer ring temperature on, short circuit F3 Refrigeration indicator light off 3s flashing 3 times condenser tube temperature on, short circuit F4 Refrigeration indicator light off 3s flashing 4 times outer exhaust pipe temperature on, short circuit F5 Refrigeration indicator light off 3s flashing 5 times defrosting H1 heating indicator off 3s flashing 1 time.

    Electrostatic precipitator protection h2 heating indicator off flashes 2 times for 3s compressor overload protection h3 heating indicator off for 3s flashes 3 times system abnormality h4 heating indicator off for 3s flashes 4 times.

    Module protection h5 heating indicator off for 3s flashes 5 times.

    Sliding door faulty fc

    H1 should be defrosted. When the air conditioner is heating, the outside will frost, and when the outside unit frosts to a certain extent, it will affect the evaporation effect. The air conditioner will pass through the tube to warm the defrost.

    During this time, the air conditioner is shut down, and the air conditioner will run automatically after a few minutes, so you don't need to turn it off.

  2. Anonymous users2024-02-14

    Can you tell me what the outside temperature is, and do you have to change the power supply when you change the mode, did this happen last winter?

  3. Anonymous users2024-02-13

    About 10 minutes is normal.

  4. Anonymous users2024-02-12

    With the arrival of winter, the weather is getting colder, at this time we all have to turn on the heating mode of the air conditioner, so how long does it take for the air conditioner to heat up? The heating of the air conditioner depends on the temperature of the outdoor orange hail, and it has a machine preheating and defrosting process according to the outdoor temperature. If the outdoor temperature is generally above 0 degrees, the ordinary air conditioner is about 15 minutes, and other brands may be longer.

    If the outside temperature is below -5 degrees Celsius, it may take longer to defrost. Therefore, we must ensure that the temperature of the place where the air circle is located, the higher the temperature, the faster the heating of the air conditioner, if the temperature is low, then the heating will take a long time.

  5. Anonymous users2024-02-11

    Or that topic, air conditioning heating depends on the power, the power of the big Zheng Yun Jianxiao quietly called to determine the heating time of the long shouting rush, generally in 5 to 6 minutes, anyway, it is normal within ten minutes, it can be opened normally.

Related questions
13 answers2024-08-06

For those commonly used modes on the remote control of Gree air conditioner, especially the cooling mode and heating mode, we are no longer familiar with it, using the cooling mode in summer and the heating mode in winter. Everyone is no stranger to snowflakes and the sun, the snowflakes represent the cooling mode, and the sun represents the heating mode. There are also water droplets that represent the dehumidification mode, which needs to be practical in spring and autumn when the indoor humidity is too high. >>>More

14 answers2024-08-06

E and K generation ** force air conditioners are different series. where K is the charm series, and E is the new Qingfeng series.

11 answers2024-08-06

Everyone knows that the air conditioner is controlled by the remote control, and if you are not careful, you will press the wrong button, and the air conditioner remote control will generally have a lock button function to prevent accidental contact and change the operating status of the air conditioner. I don't know if you have encountered the phenomenon of air conditioning being locked in the use of air conditioning, if you encounter this phenomenon of air conditioning locking, how should we solve it? The following will introduce to you the method of air conditioner unlocking, and after learning the method of air conditioner unlocking, you can unlock the air conditioner by yourself. >>>More

6 answers2024-08-06

Gree air conditioner heating mode is not.

The causes and solutions of heating are as follows: >>>More

14 answers2024-08-06

Refrigeration during protection: the compressor is stopped, and the internal fan is running; Heating: All loads are stopped. >>>More