The geothermal heat has also been washed, the gas has been discharged, and the filter screen has bee

Updated on home 2024-02-09
8 answers
  1. Anonymous users2024-02-05

    The recommended measures for not heating after geothermal cleaning are as follows:

    First of all, check that the inlet valve, inlet valve, outlet valve, and each branch valve are all open, and only when they are all opened, can the heating be smooth. After cleaning the floor heating, it is necessary to carry out the exhaust treatment, open the valve to exhaust until there is a sound of water flowing, and feel the return pipe of the floor heater.

    It's hot. <>

    The reason why underfloor heating is not hot

    1. The ground temperature erosion is incomplete.

    If the underfloor heating pipes that have not been cleaned for a long time are too dirty, or if the cleaning method used is not sufficiently cleaned, the underfloor heating may not be cleaned sufficiently and will not get hot after cleaning. At present, the physical consumables cleaning used in the world is recognized as the most thorough cleaning method in the industry, which can effectively remove the hard and thick dirt that remains in the pipeline for a long time.

    2. The pipeline is blocked during cleaning.

    In the process of using physical consumables for cleaning, the consumables are blocked by the pipeline and cannot be taken out, and the cleaner has an excuse to escape. During the service of the ground temperature users, Shicheng once cleaned the iron rods similar to cleaning tools from the pipes.

    3. The filter was not cleaned.

    The underfloor heating filter is an easy place to ignore, if the water quality of the home heating is too dirty, impurities will clog the filter, so don't forget to wash the filter when cleaning the pipes.

    4. Reasons for heating companies.

    The heating temperature of the heating company is not up to standard, and the external network.

    Insufficient water pressure, etc., geothermal heat is not hot However, this non-heat is regional, and the entire complex or the same floor may not be hot. At this time, the floor temperature user can report to the heating company with his neighbors and ask them to deal with it as soon as possible.

  2. Anonymous users2024-02-04

    1. First use or long-term unused.

    When the floor heating is used for the first time or for a long time, the water temperature is low, the heating temperature rises slowly, and the outside temperature is low, and it may take more than ten hours to reach the ideal temperature. Heating up for too long leads consumers to mistakenly think that it is a problem with floor heating.

    It's not a matter of the quality of the underfloor heating itself, just be patient and wait for the temperature to rise during the initial heating.

    2. The effective heat dissipation area is small.

    The heat generated by underfloor heating is conducted from the bottom up, and if the floor is covered and takes up most of the room, it will affect the heat dissipation. The effective heat dissipation area is small, and it is easy to mistake people for that the floor heating is not hot. Just be patient and wait for it to heat up.

    3. There is gas in the pipeline.

    If the main floor heating is hot and the return pipe is not hot, it means that there is gas in the pipe, so that hot water cannot enter the circuit circulation. Open the air bleed valve on the water separator to vent until hot water is released.

    4. The filter is blocked.

    If the water main is not hot, it may be because the water quality is too poor and the filter is clogged, affecting the normal circulation of the system. Use a wrench to open the filter, clean the filter inside, and then install it back. If you are afraid that you will damage the filter by improper operation, you can also find a professional to clean it.

    5. The pipeline pressure is not enough.

    The floor is too high, or it is located at the end of the heating of the community, and the pipe pressure is not high, resulting in unsatisfactory heating effect. Find a property or heating company to solve the problem, if it can't be solved, you can install a circulating pump to improve the circulation of hot water to achieve the desired effect.

  3. Anonymous users2024-02-03

    This requires a certain amount of warm-up time, and it is not possible to quickly dissipate the heat energy in the water pipe, so it is best not to use the wooden floor when using geothermal heat, and wait until the wooden floor can emit the temperature, then, it takes a long time, generally about ten hours!

  4. Anonymous users2024-02-02

    The solution to the frequent blockage of the geothermal inlet water filter is: you can choose to install a pre-filter, which can solve the problem of frequent blockage of the filter.

    To determine whether the filter valve needs to be cleaned, this can be compared with the temperature of the surrounding neighbors, if the temperature of the house is significantly low, it may be that the filter screen is blocked by too many impurities, it is recommended to clean. It is important to keep in mind the location of the filter valves and the logical relationship between them and each valve.

    This is because the filter valve may be installed around the diverter or on the inlet pipe. If the wrong valve is closed, the consequences of opening the filter valve are serious. Turn off the two valves at the front and back of the filter valve in the direction of water flow, and remember to close both together, as the pressure of the return water can also be very high.

  5. Anonymous users2024-02-01

    Filter. Features: Direct filtration, simple process, good air permeability, uniform and stable precision, no leakage, good regeneration performance, fast regeneration speed, easy installation, high efficiency and long service life.

    Method 1: Add a pre-filter with a larger flow rate at the knowing end of the inlet sail, so that it will not be blocked for a long time, and the effect is better than before the nuclear leak.

    Method 2: Professionals clean up the entire system once. It is estimated that the water pipe is rusty and the pipe is not purged during installation.

  6. Anonymous users2024-01-31

    It is enough to add a pre-filter with a larger flow rate at the inlet end, so that it will not be blocked for a long time, and the effect is better than before.

  7. Anonymous users2024-01-30

    Kiss! Hello, happy to answer your <>

    The reasons why the pro-filter and floor heating are not hot after cleaning are as follows: first check whether the inlet valve, inlet valve, outlet valve and each branch valve are all open, and only when they are all turned on can they be heated smoothly. After cleaning the underfloor heating, it is necessary to carry out the exhaust treatment, open the valve to exhaust until there is a sound of water flowing, and feel that the return pipe of the underfloor heater is hot.

    If you don't turn which heat is the matter of the Xuxu heating company, call the repair ** to react. 1。The reason why the pipe pressure is not enough is that the floor heating return pipe is not hot, it may be that the floor of the owner is too high or the heating end of the community is not enough, and the pipe pressure is not enough, so that the heating is in an unstable and undesirable state.

    2。After inspection, it was found that the main bar of floor heating was hot, and the return bar was not hot, so there should be gas in the pipeline, so that the hot water could not enter the circuit to start the next round of circulation. 3。

    The reason for the blockage of the filter is that the main bar of the water supply is not hot, and it is speculated that the heating water quality is too dirty, and the impurities carried by it clog the filter, so that it cannot circulate normally. 4。If the maintenance of floor heating equipment is not timely and regular, it will cause the floor heating to not be hot, and the annual scaling of the floor heating pipe is 1 mm thick, which will reduce the water temperature 6.

    Hope mine can help you <>

    Do you have any other questions?

  8. Anonymous users2024-01-29

    If the floor heating at home is the first time to use or long-term unused water temperature is low, heating up slowly, the outside temperature is low is 10 hours to reach the ideal temperature, too long heating time will also lead to the owner mistakenly think that it is the problem of floor heating.

    Solution: This is not actually a quality problem of the floor heating itself, as long as you wait patiently for the temperature to rise during the initial heating, but now the general heating room temperature is 18.

    The heat generated by floor heating is conducted from the bottom up, if there are more items on the ground, it will affect the heat dissipation effect, if the effective heat dissipation area is small, it will easily lead to mistaken thinking that the floor heating is not hot. Feast.

    Solve the problem of Hu Mask: clean up the things on the ground at home, lay less carpets, and use legged furniture for furniture, which will also make the floor heating in Xiangzhou's house hot.

    If the main pipe in the home is hot and the return pipe is not hot, it means that there is gas in the pipe, which prevents the hot water from entering the circuit circulation.

    Solution: Turn on the water dispenser at home and drain the air from the pipe until the hot water is released.

Related questions