  1. Anonymous users2024-02-05

    The junction box is marked with C, R, S, of which the capacitor (large) is connected to R and S at both ends, the power supply N line is connected to R, and C is connected to the L line output of the control board!

  2. Anonymous users2024-02-04

    Huabao fixed-frequency air conditioners, compressors and fan motors are all fixed-frequency, and they all need capacitors to start. For external units, there are two starting capacitors. The connection method is to connect the capacitor between the common end and the starting end, and then short the running end and the starting end, and then connect the live wire and neutral wire of the power supply with the common termination after shorting.

    The motor can be judged by the circuit diagram. The compressor is judged by the marking, such as R, C, S, etc. It can also be judged by the resistance method.

  3. Anonymous users2024-02-03

    Capacitors, often referred to as capacitors, are denoted by the letter C. Definition 1: A capacitor, as the name suggests, is a 'container for electricity' and is a device that holds an electric charge.

    Product Name: capacitor. Capacitors are one of the electronic components widely used in electronic devices, which are widely used in circuits in terms of DC blocking, coupling, bypass, filtering, tuning loop, energy conversion, control, etc.

    Definition 2: A capacitor, any two conductors (including wires) that are insulated from each other and in close proximity to each other form a capacitor.

    R main winding, S secondary winding, C common terminal R is connected to one end of the starting capacitor and N neutral line, and S is connected to the starting capacitor.

    At one end, C is connected to the L live wire.

  4. Anonymous users2024-02-02

    Use a multimeter to measure the resistance value, the two with the largest resistance value are connected to both ends of the capacitor, and the two with the smallest resistance value are connected to the power supply.

  5. Anonymous users2024-02-01

    Compressor starting capacitor connection methodThe compressor is connected by three wires. Whether the compressor is running or not, touch the two copper tube nuts of the outdoor unit. If the tube is cold, start it.

    If red, yellow, and black: insert the red wire plug-in into the compressor capacitor and connect it to the male plug-in with the first red wire; The yellow wire is connected to the other part of the capacitor; As for the black cable, connect it directly to the second plug from the left on the terminal board (that is, the second fan motor connected to the black cable is the same port; If the compressor line is blue, yellow, and brown: Insert the blue wire plug into the compressor capacitor and connect it to the male plug with the first red wire.

  6. Anonymous users2024-01-31

    First of all, the three lines of the compressor are distinguished, the black is the running end, the white is the control end, and the yellow is the common capacity end.

    2. First, connect the yellow common terminal to the start-up capacitor.

    3. Connect the white control terminal to the starting capacitor.

    4. After that, connect the black running end to the thread head clip.

    5. Insert the black common end into the power live wire. So the wiring is done.

  7. Anonymous users2024-01-30

    In the case of a compressor with capacitors, the capacitors are involved in operation because the compressor motor does not have a disengagement switch.

  8. Anonymous users2024-01-29

    The following methods can be used.

    1. The starting capacitor of the compressor is connected to three wires, the black wire is the running end of the capacitor, the white wire is the control end of the capacitor, and the yellow wire is the common end of the capacitor.

    2. First, connect the common end of the compressor capacitor to the power supply end.

    3. After that, connect the control end of the compressor capacitor to the relay circuit.

    4. After that, install the line clip on the black running end.

    5. After that, connect the running end of the starting capacitor to the power live wire. So the wiring is done.

  9. Anonymous users2024-01-28

    Summary. 1. First of all, distinguish the three lines of the compressor, the black is the running end, the white is the control end, and the yellow is the common end.

    2. First, connect the yellow common terminal to the start-up capacitor.

    3. Connect the white control terminal to the starting capacitor.

    4. After that, connect the black running end to the thread head clip.

    5. Insert the black common end into the power live wire. So the wiring is done.

    Hello, I have seen your question and am sorting out the answer, please wait for a while 1. First of all, distinguish the three lines of the compressor, the black is the running end, the white is the control end, and the yellow is the common end. 2. First, connect the yellow common terminal to the start-up capacitor. 3. Connect the white control terminal to the starting capacitor.

    4. After that, connect the black running end to the thread head clip. 5. Insert the black common end into the power live wire. So the wiring is done.

  10. Anonymous users2024-01-27

    The air conditioning compressor plays the role of compressing and driving the refrigerant in the air conditioning refrigerant circuit. Air conditioning compressors are generally installed in outdoor units. The air conditioning compressor extracts the refrigerant from the low-pressure area and sends it to the high-pressure area for cooling and condensation after compression, and dissipates heat into the air through the heat sink, and the refrigerant also changes from gaseous to liquid, and the pressure increases.

  11. Anonymous users2024-01-26

    Different brands of air conditioners and different brands of compressors have different capacitor connection methods.

    It is recommended to find the electrical wiring diagram on the nameplate of the compressor or the electrical wiring diagram given by the air conditioner manufacturer posted on the back of the air conditioner control box, which will have a clear compressor capacitor wiring method marked, and the correct wiring is based on the capacitor wiring information marked in the wiring diagram.

  12. Anonymous users2024-01-25

    Answer: The starting capacitor of the air conditioner compressor needs to be replaced in the case of power failure. The specific method of operating the shed limb is as follows:

    First remove the original Changrang capacitor, then wire and fix the new capacitor, and finally power on the test again. If you do not understand the Chainlink circuit, it is recommended that you ask a professional maintenance personnel to replace it.

  13. Anonymous users2024-01-24

    The pressure of the air conditioner is corrected and the compression machine, then its capacitance width is generally on the outside of the chassis, at this time the chassis can be replaced, generally speaking, in a professional repair, sometimes you don't understand, don't break the clever and rough components, that is particularly troublesome.

  14. Anonymous users2024-01-23

    Summary. Where is the starting capacitor of Gree air conditioner compressor pro, hello! The starting capacitor of the air conditioner compressor is in the junction box of the compressor of the outdoor unit or under the fixed plate of the outdoor electric control; You can find the location of the starting capacitor by following the two white wires that come out of the compressor.

    Hope it helps!

    Where is the starting capacitor of Gree air conditioner compressor pro, hello! The starting capacitor of the air conditioner compressor is in the junction box of the compressor of the outdoor unit or under the outdoor electric control fixed plate; You can follow the two white wires from the compressor to find the location of the starting deficit capacitor. Hope it helps!

    The position of the capacitor of the external unit of the Gree air conditioner.

    Hello! 1. The capacitor position of the external motor of Gree air conditioner is in the junction box of the compressor of the outdoor unit or under the fixed plate of the outdoor electric control; 2. You can follow the two white wires connected by the compressor to find the position of the starting capacitor. 3. There are three main capacitors of split air conditioners, one is the compressor starting capacitor, one is the indoor fan motor starting capacitor, and the other is the outdoor fan starting capacitor.

    4. The starting capacitor is mainly to provide a large enough starting torque for the start of the compressor and fan, so that the motor can rotate. Hope it helps!

  15. Anonymous users2024-01-22

    The normal compressor capacitor is four plug-in heads. Pairs of two. There is a total of three lines on the compressor capacitor.

    One is a set of plugging between the compressor neutral line and the power supply neutral line. Both wires are the same color and should be green or blue. Then, the other end of the compressor capacitor is plugged into the common winding wire on the compressor.

  16. Anonymous users2024-01-21

    There is a knot in the middle of the capacitor, there is a starter on the line, and the other side is the compressor, is it knot to the neutral line or the live line, there is C, R, S on the compressor, and the knot is there.

  17. Anonymous users2024-01-20

    The compressor capacitor is not divided, just buy back the same one, I just changed one last month.

  18. Anonymous users2024-01-19

    How to dismantle it, how can it not be connected?