-
Our mechanical watches often have the situation that the time is not accurate, and most people wonder if the mechanical watch is broken. There are many reasons why a mechanical watch can be parked, but there are several main reasons.
1. Insufficient kinetic energy: The watch is not winded enough, and the kinetic energy is insufficient. In particular, automatic watches require more arm movement, and the winding efficiency is very low. If you usually exercise a little bit, you can wind it manually, which can ensure enough kinetic energy.
2. Gear failure: Gear train failure such as deviation wheel and center wheel failure will lead to the condition of stealing stop of the watch. These situations are often not easy to detect and require disassembly, careful inspection and testing to find out the problem and solve the problem.
3. Lack of maintenance: mechanical watches should be maintained every 2-3 years or so. If it is not maintained for a long time, a large amount of oil sludge will be generated inside. Friction between gears increases, causing slippage.
There will be after-sales ** on your warranty link, call after-sales ** to inquire about the after-sales address.
-
This watch is not good, it is taken off from the wrist and put on the table at nine o'clock in the evening, and it stops at two or three in the morning, unless it is worn at night, it must be stopped the next day. A good watch will not stop until it is worn the next day.
-
This is a chronograph style, the second hand is the small dial, and the big second hand is the key on the right before walking, which is used for timekeeping.
-
Mine is the same, I wore it normally the day before and stopped the next day!
-
In fact, there are many reasons why mechanical watches do not go, such as: bumps, movement gear misalignment, magnetization of the watch, shelving for a long time, sludge drying, etc., generally divided into two kinds, the first is because of insufficient kinetic energy. The second is due to a malfunction of the mechanical watch.
Therefore, don't panic too much when you find that the mechanical watch is not leaving, and first distinguish which kind of big one it belongs to.
1. Insufficient power reserve. You need to check whether the power is sufficient, if the amount of movement of the self-winding mechanical watch is small, it may also cause insufficient power reserve, you can supplement the power by manual winding, and then observe whether there is a phenomenon of speed and slowness, if it is still recommended to go to the store for testing.
2. The power is insufficient. If the quartz watch suddenly finds that it is slowing, it is likely to be caused by insufficient battery energy.
3. Having been beaten or impacted. The watch is very tight, if it is hit or dropped, it may cause loose damage to the internal parts, and it may also cause time problems, so it is recommended to go to the store for testing.
4. Maintenance is required. A lack of oil or wear and tear of the internal parts of the movement can cause time-keeping problems and require maintenance.
5. Under the influence of ambient temperature, the watch is magnetized: if the hairspring of the watch is magnetized, the watch will not be accurate. The influence of the wearer's usage habits may cause an increase in the error of the time, which will be sent to the store.
Note: 1. Mechanical watches vary according to the model and manufacturing quality of the movement, and the error of the general watch within 30 seconds per day is within the normal range. Some of the higher precision movements can reach around 10 seconds.
-
Stop, there may be the following reasons:
1. See if the crown is pulled out, the crown is pulled out, and the watch stops.
2. Whether the second hand touches the glass, there will be a circle mark on the glass.
3. Whether the three watch hands are not well balanced, causing contact and causing stopping.
4. Whether the battery is exhausted or not, it generally needs to be replaced in 1-2 years.
-
Each watch has a different movement type, which leads to differences in the accuracy of each watch. The watch relies on the internal mechanism to control the uniform and accurate time of the watch, because the internal mechanism of the watch is affected by many external factors, such as gravity and ambient temperature differences, which will cause errors in the watch. In general, the error of mechanical watches is calculated on a daily basis, although they are different due to the differences in the movement model and manufacturing quality of each watch, but the error is generally less than 30 seconds per day, and this degree of error is normal.
Of course, some of the higher precision movements can have an error of about 10 seconds. In general, there are several situations that will cause the sudden increase in the timing error of the watch.
-
<> Mido. The abbreviation of the day of the week is written in English and German, and can be switched between them by adjustment. The comparison of Chinese, English and German weeks is as follows:
Week: Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday;
English: mon, tue, wed, thu, fri, sat, sun;
German. mon、die、mit、don、fre、sam、son。
Mido watch to adjust the time and date steps:
1. Wind, crown in position i ib, not pulled out. Restart the watch and turn a few crowns clockwise, or shake the watch a few times.
2. Set the time method, carefully pull the crown to position iii, and the second hand stops immediately. Turn the crown forward or backward until the hands show the correct time.
3. Quick adjustment method for date and day, pull the crown to position II, then rotate clockwise until the watch displays the correct date, and counterclockwise to change the day of the week setting.
-
It's normal for a Mido mechanical watch to stop when it's not in motion.
Automatic watches rely on the natural movements of your arm to replenish power. If there is too little activity in normal times, the movement will not reach the state of full or close to full chain, and the power reserve will be insufficient. So when the watch is left for a day or even less, it stops.
If you usually have little activity, you can shake the watch from side to side dozens of times before putting it down to replenish its power. If the watch supports manual winding, it is of course better to twist it manually.
-
A fully automatic mechanical watch that operates by the action of an automatic winding mechanism that winds the mainspring when the rotor is turned in any direction (visible on the transparent bottom cover). It is conceivable that only by wearing the watch on the hand, the rotor will also rotate to generate energy as the arm moves. Generally, a fully automatic watch should be worn on the hand for more than 8 hours a day to replenish the energy of the clockwork, but it is not absolute.
Only when you wear it on your hand and constantly replenish the energy of the clockwork, will the watch not stop. Nowadays, there are people who work in the office, and the watch often stops and goes, in addition to the movement, because the wearer itself has insufficient exercise to replenish enough energy to the mainspring.
-
Mechanical watches are divided into manual mechanical watches and automatic mechanical watches, lack of power is an important reason for the watch to slow down or stop the watch, manual mechanical watches can be wound directly when they are slow, and the reason why automatic mechanical watches are slow is mostly because of insufficient wearing time or the arm does not maintain a normal amount of movement, and it can be directly manually wound to supplement the power.
-
The main reasons why the watch does not go are: the movement gear is misaligned, the watch is magnetized, bumps, and the oil sludge is dried for a long time when it is left on hold. The most common reason for the failure of the watch not going is the lack of power of the watch and the movement of the watch does not work.
When the mechanical watch stops, the priority is to think about whether it is caused by lack of power. Hand-wound watches should be wound at the same time every day as much as possible so that the watch can operate with sufficient energy for the next 24 hours. Quartz watches, on the other hand, can be actively wound and should be worn on the hand for more than 8 hours a day to replenish the mainspring.
Lack of exercise after wearing it will also show that the watch does not move or stop.
-
Are you buying a fully automatic mechanical watch? A fully automatic mechanical watch can be worn for 8 hours a day to ensure that you will not stop waking up!
-
Automatic, relying on your movement to increase the kinetic energy of the watch to go, can also be manually wound.
Laser whitening can be chosen, which is currently used as a medical aesthetic technique for medical whitening. This non-surgical plastic surgery method is very popular in today's society. Laser whitening has a high degree of accuracy and safety, will not affect the surrounding adjacent tissues, and has a definite curative effect, safe and reliable, small pain and deeply rooted in the hearts of the people, laser whitening ** can not affect work.
Nothing. Anyway, what should be said is always what must be said. >>>More
If you're single, you're single, and if you're used to it, there's nothing wrong with it. Without love, you still have family affection, and you still have friendship, don't you? If you feel lonely alone, you might as well go out with friends more, sooner or later find your other half, don't be nervous! >>>More
No matter what the reason for being late, if the company has a system, it is necessary to clarify the attendance system on the day of the employee's entry, which must be observed every day, the key point must be emphasized, and each time you are late you need to implement it in accordance with the system. If the company does not have a corresponding system, it is necessary to formulate an attendance system in time and train it in place. After the training, if any employee is late again, he will be punished according to the system. >>>More
Eat your brain and replenish your brain. Eat more pig brains, fish, walnuts.