Thermal shock tests are divided into two categories:
Two-chamber thermal shock test chamber and three-chamber thermal shock test chamber.
1. Two-box thermal shock test chamber model: HYTW-50, HYTW-100, HYTW-200, HYTW-300, HYTW-504, HYTW-100.
2. Parameters of two-box thermal shock test chamber:
1.Temperature shock range (+60 +150) (-40 -10) ; 60~+150)℃/(-55~-10)℃;60~+150)℃/(-65~-10)℃;
2.Preheating and precooling temperature range: preheating: +60 +180 Precooling: -80 0 ;
5.Temperature deviation:
Three, three-chamber thermal shock test chamber model: HYTS-80, HYTS-100, HYTS-150, HYTS-252, HYTS-480
Fourth, the parameters of the three-tank thermal shock test chamber:
1.Temperature range of working tank: -40 150 ; -55~150℃;-65~150℃。
3.High temperature bath temperature range: 600 200 ;
4.Cryogenic bath temperature range: -65 0 ; -70~0℃;-80~0℃。
-
The thermal shock test chamber has beautiful appearance, reasonable structure, advanced technology, exquisite material selection, simple and convenient operation performance and reliable equipment performance. The equipment is divided into three parts: high temperature box, low temperature box and test box, which adopts the special heat insulation structure of single mold socks and the effect of heat storage and cold storage. Advantages of Thermal Shock Test Chamber:
Using the most advanced measurement device, the controller adopts a large color LCD man-machine touch dialogue LCD human-machine interface controller, which is simple to operate, easy to learn, stable and reliable, and displays the complete system operation status, execution and setting program curve in Chinese and English.
With 96 test specifications set independently, the impact time is 999 hours and 59 minutes, and the cycle cycle can be set for 1 999 times, which can automatically run the refrigerator without code, realize automation to the greatest extent, reduce the workload of operators, and automatically start and stop work at any time;
There is a 50mm diameter test hole on the left side of the box, which can be used for external power supply load wiring test parts.
It can independently set the functions of high temperature, low temperature and hot and hot shock, and when performing the cold and hot shock conditions, you can choose the function of two-tank or three-tank type and cold punching and hot punching, which has the function of high and low temperature testing machine.
It has fully automatic, high-precision system loop, any part action, complete locking processing, all of which are controlled by automatic calculation, and have high temperature control accuracy.
-
A thermal shock test chamber is a type of testing equipment used to test the sensitivity of materials to temperature changes. The chamber is tested for the tolerance of the sample by rapid cooling and heating over a predetermined temperature range.
Advantages: Rapid temperature changes can be carried out, simulating thermal and cold shocks in real environments.
The impact resistance of many different materials can be tested.
Automatic control is possible, and the results are accurate.
Disadvantages: The equipment is expensive and requires a certain investment.
Maintenance and repairs are complex.
Temperature control accuracy can be compromised, so regular calibration is required.
-
The Thermal Shock Test Chamber is a widely used industrial test equipment to evaluate the durability and reliability of objects by simulating their performance changes at extreme temperatures.
Advantages include accurate simulation of temperature changes, ease of operation, high reliability and stability. At the same time, the thermal shock test chamber can greatly improve the quality and reliability of the product, so as to meet the demand for high-quality products in the industrial field.
However, there are also disadvantages of the thermal shock test chamber, which are mainly reflected in the relatively high equipment, large space occupation and high maintenance costs. Therefore, when purchasing and using a thermal shock test chamber, it is necessary to consider its advantages and disadvantages, and make a reasonable choice according to your own needs and actual conditions.
-
In order to ensure the correct use of the thermal shock test chamber, avoid damage caused by improper use of the instrument and products, and improve the validity, authenticity and accuracy of product test data. Equipment operators should pay attention to the daily inspection of instruments, and at the same time pay attention to the following operating specifications:
1.Thermal shock test chamber is in operation, please do not open the chamber door unless necessary.
2.Avoid turning off and then turning on the refrigeration unit in the three-point smile.
3.Do not connect the power supply used for the test sample to the power supply of the machine.
4.The lights should be turned off at all times except when necessary.
5.During the test, when the temperature of the cryogenic chamber exceeds 55, the chiller should not be turned on.
6.Circuit breakers, over-temperature protectors, please check regularly.
7.Before doing low temperatures, the studio should be wiped dry and dried for 1 hour at 60 hours.
8.It is forbidden to test **, flammable and highly corrosive substances.
9.The basket rails and racks should be lubricated regularly.
10.In any cross-section perpendicular to the prevailing wind direction, the sum of the test load cross-sectional areas shall not be greater than one-third of the working cross-section.
11.The sample to be tested should be fixed in the middle of the sample frame as much as possible, and should not be placed on one side at will, resulting in the tilting of the basket.
-
The major system composition of the thermal shock test chamber needs to be suitable for the adaptability test of major electronics, electricians and other equipment under the conditions of rapid changes in the ambient atmospheric temperature, and it is also a good assistant for screening the beginning of the failure of its components. Detect the structure of each material and composite material, so that under a certain temperature condition, after extremely high temperature and extremely low temperature continuous environment to endure the degree, the internal structure is inseparable from the cyclic operation of a variety of systems and the mutual promotion between systems. The advantages of the three systems are very prominent, and the use of them is high-configuration, and the quality is considerable.
Category 1: Control systems. It adopts microcomputer electronic digital control mode, which is precise, accurate, stable and reliable; It is also a color touch LCD, Chinese and English microcomputer temperature control and liquid crystal touch screen direct button type control;
Category III: Refrigeration systems. The refrigeration system is to ensure the cooling rate and minimum temperature requirements of the test chamber, so that the test chamber is a binary cascade air-cooled refrigeration system composed of a set of compressors, and the cascade refrigeration system includes a high-temperature refrigeration cycle and a low-temperature refrigeration cycle, and uses HFC environmentally friendly refrigerant, the design of the binary ultra-low temperature refrigeration system is exquisite, the cooling is fast and the efficiency is high.
The three types of systems are analyzed and illustrated to further understand the components of the thermal shock test chamber. In the multi-functional thermal shock test chamber to perform a variety of tests, temperature control and temperature range values are often the most important.
-
<>1. Placement of samples: In fact, when choosing a thermal shock test chamber, the first business will consult the volume of the sample to ensure that there will be no test errors due to the excessive volume of the sample and the lack of smooth air circulation in the studio.
2. Check before the experiment: Before the test, you must turn on the power cord of the equipment and check whether it is correctly grounded, whether the external water cooling system is connected normally, and whether the water source used is clean.
3. Test conduct: In order to ensure the safety of the operator and the accuracy of the test results, we can not open the door frequently during the test, and before setting the temperature, we also need to ensure that the door of the cold and thermal shock test chamber is locked to avoid temperature leakage and cause the required temperature in the studio to be unable to reach the required temperature.
4. The end of the experiment: After the end of the test, the power supply of the equipment must be cut off to avoid leakage, and it is also necessary to pay attention to the fact that the user should not face the door of the box when taking the sample, so as to avoid scalding and frostbite caused by the cold or hot air rushing out of the studio.
There is so much to say about the use of the thermal shock test chamber, and we should strictly follow the instructions given by the manufacturer in the process of use, so that we can make the life of the equipment longer.
-
<>1. The shell of the cold and thermal shock test chamber is made of cold-rolled thin steel plate, and the surface is sprayed with plastic, which is beautiful and durable, while the inner tank studio is made of stainless steel plate to make the surface smooth and clean.
2. The refrigeration system is installed on the right side of the main box, and the refrigeration unit adopts a unit with good performance, which is convenient to install and reliable in performance.
3. The structure adopts the design idea of no jacket and combination, which has a concise appearance, an ideal assembly method, a compact box structure, and is extremely convenient for maintenance and use.
4. The test chamber is equipped with two sealing devices, so the sealing performance is extremely good, and it is equipped with a large-size observation window for users to easily observe the test situation of the sample items. The inner and outer door seals are made of silicone rubber material, which is safe and non-toxic.
5. Safety protection function, power overload, leakage, short circuit, compressor, grounding, overtemperature and other protection measures and alarm sound prompts.
6. The right side of the studio is equipped with circulating devices, heaters, refrigeration evaporators and other components, and the top is equipped with a pair of blast motors to circulate hot and cold air in and out of the studio to ensure the temperature requirements of the hot and cold shock test chamber.
7. The touch digital display instrument has the functions of programming, curve display, PID self-tuning, fault display and so on.
I don't know if it will be helpful for you to buy it, if you want to know more about the knowledge of environmental testing equipment in the future, you can continue to pay attention to our company!
-
The thermal shock test chamber is used to test the material structure or composite materials, so that the sample can withstand the continuous environment of extremely high temperature and extremely low temperature in an instant, so as to detect the chemical changes or physical damage caused by thermal expansion and contraction of the sample in the shortest possible time, and these data can be used as an important basis for the next production improvement sample.
-
The thermal shock test chamber is a necessary testing equipment for metal, plastic, rubber, electronics and other material industries, which is used to test the material structure or composite materials, which can be endured in an instantaneous continuous environment of extremely high temperature and extremely low temperature, so as to detect the chemical changes or physical injuries caused by thermal expansion and contraction of the test sample in the shortest time. The test method satisfies the cold and hot shock test chamber: GB high and low temperature impact test.
The high and low temperature impact test chamber is the temperature shock test chamber and the cold and hot shock test chamber, which are mainly for the adaptability test of electrical and electronic products, as well as their original components and other materials in the environment of rapid temperature changes. It is mainly used for environmental simulation tests on the physical and other related characteristics of the product in accordance with the requirements of national military standards or user-defined requirements, under the conditions of instantaneous changes in high temperature and low temperature, and after testing, through testing, to judge the performance of the product, whether it can still meet the predetermined requirements, so as to be used for product design, improvement, identification and factory inspection.
-
The thermal shock test chamber developed by Zhongchuang Alliance can be used to test the degree to which the material structure or composite material can withstand in an instantaneous continuous environment of extremely high temperature and extremely low temperature, so as to test the chemical changes or physical damage caused by thermal expansion and contraction in the shortest time. The applicable objects include metal, plastic, rubber, electronic and other materials, which can be used as the basis or reference for the improvement of its products.
-
The thermal shock test chamber is suitable for the safety performance test of electronic components, providing reliability test, product screening test, etc., and at the same time, through this equipment test, the reliability of the product and the quality control of the product can be improved. High and low temperature impact test chamber is a necessary test equipment for aviation, automobiles, home appliances, scientific research and other fields, to assess and determine the parameters and performance of electrical, electronic, automotive electrical appliances, materials and other products after the temperature environment impact change in high and low temperature tests, and the adaptability of use, suitable for schools, factories, military industry, research stations, and other units.
-
The thermal shock test chamber is also called the thermal shock machine, which is suitable for the safety performance test of electronic components to provide reliability test, product screening test, etc., and at the same time, through this equipment test, the reliability of the product and the quality control of the product can be improved.
Shanghai Hesheng Instrument Technology Co., Ltd. is the best manufacturer of thermal shock test box is metal, plastic,
The necessary testing equipment for rubber, electronic and other material industries is used to test the degree to which the material structure or composite material can withstand in a continuous environment of extremely high temperature and extremely low temperature in an instant, so as to detect the chemical changes or physical injuries caused by thermal expansion and contraction of the test sample in a short time. The test method satisfies the cold and hot shock test chamber: GB high and low temperature impact test.
-
The three-box type is divided into: high temperature area, low temperature area, room temperature area three boxes, the product is placed in the test area, driven by a high-pressure cylinder for high and low temperature impact test, the test sample is stationary, also called static cold and hot shock test box;
The two-box type is divided into two boxes, the high temperature area and the low temperature area, the product is placed in the basket, and the basket is driven to the high temperature area or lowered to the low temperature area through the transmission chain.
Doaho high-temperature test chamber is a relatively large demand in the current environmental test market, because the market requirements and standards for the safety performance of various products are getting higher and higher, so the demand for reliability test equipment at various temperatures has increased sharply, of course, the market demand has increased, so there are more and more high-temperature test chamber manufacturers in the market, so users are more concerned about the high-temperature test chamber manufacturers. It is true that if you don't understand an industry, you really can't tell which one is good and which one is bad, but there is no more objective and accurate answer to which one is good for the high-temperature test chamber manufacturer. Therefore, it is recommended that users first understand the fundamental reasons for determining the quality of a high-temperature test chamber, and let's take a look. >>>More
Environmental test, especially the reliability test, the test cycle is long, the object of the test is sometimes a military product of high value, in the process of the test, the test personnel often have to operate or test around the site, so the environmental test equipment must have the characteristics of safe operation, convenient operation, reliable use, long working life, etc., to ensure the normal progress of the test itself. All kinds of protection, alarm measures and safety interlock devices of the test equipment should be perfect and reliable to ensure the safety and reliability of the test personnel, the tested product and the test equipment itself.
As far as I know. The two are the same device and there is no difference. >>>More
Clause. 1. The test cloth should be replaced regularly, and the new test cloth should be cleaned first, and the temperature measuring body should be wiped with a cleaning cloth when replacing. >>>More
Constant temperature and humidity chamber (LRHS-101-LH) will need to use water when doing temperature and humidity tests, generally using a special water tank or an external water tower to specifically supply water, if the water quality is not good, there will be some impact on the equipment, so what are the standards for the test water of the equipment? Does it affect the use of regular tap water? >>>More