If you find that the floor heating is leaking, please close the inlet and return valves immediately to avoid further damage and even damage to the neighborhood.
Please ask a professional floor heating maintenance company to repair, it is best to replace all the coils with water leakage (damage caused by floor heating backfill), but in actual life (decoration has been completed or has been occupied) because the whole road pipe replacement is too complicated, it is generally to knock on the problem and replace a leaking section of the pipe.
How to prevent water leaks in underfloor heating?
1. Floor heating construction is generally entered after the completion of hydropower installation, and shall not be cross-operated with other types of work.
2. Three pressure tests should be done for the installation of floor heating: after the floor heating pipe is laid, after the concrete backfill is completed, and before cleaning after all the decoration projects are completed.
3. When using floor heating in the coming year, it should be heated in stages, gradually increase the temperature, and do not adjust the temperature to the highest at one time.
4. Install floor heating water quality filters, use antiscaling agents, improve water quality and reduce the frequency of floor heating cleaning.
5. Do not disassemble and assemble floor heating without permission, except for professionals.
6. Please choose a regular HVAC company and decoration company. Don't be greedy for a moment of cheap material selection, bury hidden dangers!
Floor heating is buried in the ground, if there is a water leak will cause trouble for users downstairs, so we had better check whether our floor heating is leaking, find it in time, and deal with it, so as not to cause unnecessary economic losses. In fact, we can do some measures to prevent water leakage when using floor heating, which is also mentioned above. When we find a leak in the floor heating, it is best to ask a professional to check it, and it is specific that there is a water leak in that part, so that we can deal with it in time.
-
According to the experience of Xinjiang Urumqi Hongsheng Tianxiang Floor Heating Company for many years, the water supply temperature of the low-temperature hot water floor radiant heating system should not exceed 60, and the working pressure of the heating system should not be exceeded. Underfloor heating systems should be cleaned once a year before use.
The specific method is as follows: first close the inlet and return valves connecting the conduit, then open the filter, take out the filter screen and clean it, check whether the filter screen is damaged or blocked, if there is damage, it should be replaced with a filter screen of the same specification, and it can be installed as it is (note: in the process of disassembling and assembling the filter screen, do not let debris enter the pipe).
In the process of starting water supply or using the floor heating system, air may accumulate in the pipeline, which affects the heating effect, and the release valve of the water distributor and collector can be opened to discharge the gas, and the method is the same as that of traditional heating.
The water flow of each branch of the system can be adjusted by adjusting the ball valve on each branch, and the purpose of controlling the temperature of each part can be achieved, but the adjustment should be cautious so as not to affect other branches.
The floor heating pipe laid under the ground is only about 3-4cm away from the floor surface, and it is easy to hurt the floor heating pipe by smashing and knocking on the ground, so it is strictly forbidden to knock and impact the ground where the floor heating pipe is laid, and it is strictly forbidden to wedge any sharp object into the ground to prevent damage to the floor heating pipe. When you need to place heavy items (more than 2 tons of square meters) on the ground, please contact the property management company or our company first.
When the user really needs to drill holes in the roof, it is important to pay attention to the depth of the drilling hole should not exceed the thickness of the floor slab structure to prevent damage to the upper floor heating pipes.
There are many exposed pipes near the water collector, so attention should be paid to protection, and it is best to add a protective cover.
It is strictly forbidden to place high-temperature heat sources near the water collector and on the ground where the floor heating pipes are laid to prevent damage to the pipeline system.
When there is no heating in winter, attention should be paid to protection to prevent the water separator parts from cracking and the water in the heating pipe from freezing and blocking the pipe.
When you encounter problems that you can't solve during use, such as no heat, water leakage, etc., please contact Urumqi Hongsheng Tianxiang Floor Heating Project in time, and we will solve your problems as soon as possible.
-
What are you referring to that is broken? If the plumbing parts are broken, you can change your clothes directly, and if the pipes in the ground are broken, it will be troublesome, and you have to smash the ground to repair it. If it's more than one, start anew.
-
Yours is there broken?? Is it a water leak or a problem with the boiler? Floor heating is a bit complicated, don't just find someone If you have any questions, you can send me a message and I'll help you get it professionally.
-
Repair! Lay the tiles and smash the tiles. Replacement of parquet floors.
-
Did the impurities plug the pipe? In that case, you can find a professional cleaning to deal with it.
-
Only the problem can be identified and repaired.
-
Ha ha! The question is too simple!
If it's broken, fix it!
Fix what is bad!
Try to make an accurate judgment and reduce unnecessary losses!
-
Find the reason, see whether it is the problem below or the problem above, the above problem is easy to solve, the following is very troublesome, if you choose our carbon crystal floor heating, the solution is very simple.
-
Mul. 1. If you use it for too long, there is dirt in it that needs to be cleaned up. After a few years of floor heating, there will be dirty things such as scale in the internal pipeline, which will lead to blockage and cause the heating to be not hot enough, so you must ask a professional master to wash the internal pipeline with high pressure after a few years of use.
Mul. 2. There is gas in the circuit during water injection. Every year, water will be injected to test whether the heating is leaking, and before heating after water injection, if there is gas in the heating pipeline, it will cause the return water to be poor, resulting in the whole circuit is not hot. Mul.
3. It may be that there is too much ground covering. The principle of floor heating is radiant heating from the bottom up, if the ground is covered with blankets and other items, such as wardrobes and other furniture without feet directly in contact with the ground, then the heat generated by floor heating can not fully dissipate heat. Mul.
-
Floor heating pipes are broken, quick repair methodQuick couplings.
This method is mainly to use two copper pipes to directly connect the broken pipe.
Patching is quick and easy.
However, it should be noted that this method is not advisable in principle for floor heating pipes made of PEX material. Because it has been buried for a long time.
In the underground, water leakage will occur due to corrosion and uneven heating.
Besides, it may be okay in the early stage, but it can't be guaranteed later.
Be cautious!
Hot melt joints. This practice is to use the damaged underfloor heating pipes at both ends with heating.
to carry out converged connections. It's a bit more complicated than the first way, so it requires a certain amount of experience and skill.
Replace the circulation circuit.
This refers to the replacement of the circuit that damaged this part of the pipeline, and needless to say, this method is certainly the most secure, but increased.
You can't run away with a lot of budget costs!
In addition, it should be noted that the replacement needs to be filled in the ground.
Before the construction of the layer, if the ground filling layer has been completed, that.
It is inconvenient to carry out replacement construction.
Hot melt welding. The so-called hot melt welding is to use hot melt technology to combine the tube with.
The tubes become tighter and appear to be fully fused.
Compared with the former, this treatment has better sealing, and it is not easy to leak water no matter how it is used.
In addition, the floor heating pipes are welded by hot melt, and don't forget to be right.
It conducts suppression tests, and photographs to record, one is as with.
The plumber communicates the evidence of the claim, one is to facilitate the later appearance. Problem repair.
-
Can a leaking floor heating pipe be repaired?
According to the specification, the floor heating pipe buried in the ground is not allowed to have joints, if the user installs the floor heating when choosing the regular manufacturer material, the general phenomenon of floor heating pipe leakage is also very rare, and the floor heating pipe is usually "decoration cut, cut, hit" leakage. So is there a way to fix it in this case?
Hot melt, this is also the only option! First of all, users should know that only PERT floor heating pipes and PB pipes can be hot-melted, and PEX pipes do not have hot-melt conditions due to the characteristics of the material itself.
The following author analyzes some precautions when hot melting of floor heating pipes based on years of experience!
Clause. 1. Before hot melting, the pipe at the leakage point should be cut vertically with a professional pipe cutter. The incision must be smooth, and the burr must be removed before hot melting.
Clause. 2. Before the floor heating pipe is melted, wipe the inner and outer walls of the floor heating pipe with a dry cloth.
Clause. 3. Use pipe fittings that are consistent with the size of the damaged pipe or the same brand as the damaged pipe, or the quality is worried about the damaged pipe, and the hot melt machine is equipped, and then the electricity is heated.
Clause. Fourth, use a soft pencil first, and then use a hard pencil to mark the line at the hot melt end of the pipe according to the required length.
Clause. 5. After heating to the specified time, quickly remove the pipe and pipe fittings from the heating sleeve and the heating head at the same time, and quickly insert the pipe into the specified depth of the pipe fittings without rotation, so that the joint forms a uniform flange, and corrects the hot melt joint, but it can not be rotated. Keep the fittings and pipes at an angle of 180 degrees.
Clause. 6. After the specified time is reached, the suppression test is carried out, and it can be used without pressure relief.
Hot melting of floor heating pipes requires a certain amount of experience and technology, and if it is not operated properly, it may be wasted.
-
Rubens floor heating pipe, if the laid pipe is damaged due to construction, it can be repaired with pipe fittings to avoid the waste of the whole pipe. In the construction, the amount of pipe fittings can be reduced by coiling and bending, so as to reduce costs and avoid fractures.
-
Exposed pipes can be used with quick couplings.
The buried pipe must be replaced.
-
Dear, I'm glad to answer for you: the repair method for electric floor heating is as follows: use a live wrench to open the filter, clean the filter inside, and go back from the Xin'an section to search and install the leakage, or you can find professional personnel to clean it.
If the floor heating is not hot after being turned on for a long time, it may be that the floor heating system has not been turned on, this reason is not a technical problem, just like our TV has no image, your first reaction may be that the TV is broken, or it may be that you did not plug in the power cord properly. Floor heating broken maintenance method: check whether the main valve of the system is open, if the valve is open, check the regulating valve on each manifold, if the regulating valve on the manifold is open, there may be a problem with the underfloor heating system.
Liansu floor heating pipes are OK. Lesso floor heating pipes are non-cross-linked polyethylene pipes that can be used for hot water. >>>More
Property, exhaust valve leakage for what floor heating. Or you didn't make it clear. >>>More
Methods of laying underfloor heating.
1. Installation method of dry floor heating. >>>More
In daily life, sometimes you accidentally puncture the screen window, do you need to replace the whole screen window for a small hole? With the new screen patches, it is easy to repair broken screens, especially for women living alone and renters, and the problem is immediately solved without losing the aesthetic characteristics. >>>More
In our previous generation of Chinese families, many of the feelings between husband and wife are not good, resulting in insufficient care for both parties in family life, when the child appears, the wife will transfer the love that originally belonged to the husband to the son, and treat the son as a "lover". >>>More