  1. Anonymous users2024-02-06

    Functions of the power environment detection and control system in the computer room:

    1. Remote monitoring:

    The computer room environment monitoring host is a multi-functional monitoring host that can be monitored in real time 24 hours a day, which can find faults in time, and can directly use the equipment with remote control to set parameters with a variety of alarm methods, providing perfect alarm methods, email, sound and light alarms.

    2. Air conditioning equipment monitoring

    The air conditioner controller is used to centrally control the on, off, and self-start of the air conditioner when the power is off, and the temperature and humidity sensor can be linked to quickly deal with the temperature and humidity in the computer room if the temperature and humidity are too high or too low.

    3. Temperature and humidity monitoring

    The 86-box temperature and humidity transmitter has a liquid crystal display, which can display the temperature and humidity value in real time; The measurement unit is used to measure accurately; On-site self-calibration, good long-term stability, small drift; Linkage air conditioning and fresh air system, set the temperature and humidity threshold, and when the threshold is triggered, the air conditioning and fresh air system will be turned on or off.

    4. Water leakage monitoring

    Regional water leakage detection, positioning water leakage detection, when there is water leakage, send out alarm information in time to notify the staff to carry out water leakage treatment.

    5. Fire monitoring:

    The smoke alarm has all-round 360 detection, and the use of photoelectric smoke sensing devices can detect the smoke generated during the fire in time, with an alarm function, and a strong sound can be emitted after the alarm.

    6. Mains power supply:

    The power-off alarm is adopted, which can be compatible with the detection of single-phase AC20V, three-phase three-phase system, three-phase four-wire system AC380V, and the internal algorithm can automatically identify the equipment of the external power grid with a track-type shell, which can be wall-mounted or set up with a standard DIN 35mm track on site.

    7. Intelligent access control:

    The human body infrared detector can be used for all-round 360 detection, the dual pyrothermal infrared sensor with alarm and advanced signal analysis and processing technology, and the automatic temperature compensation function with ultra-high detection and false alarm performance.

    8. Real-time inspection:

    The cloud platform is deployed on a public network server, which can access all network devices in the computer room monitoring solution. It can be monitored remotely, and users can log in to their accounts anytime and anywhere; Multiple levels of permissions can be accessed, and the convenient computer room environment is not controlled by time and place; Real-time data and historical data can be queried, and printed and so on.

    Through the analysis of the function of the dynamic environment detection and control system in the computer room, do we have a general outline? The landing cases that can be used for reference and the solutions that can be directly implemented will be shared one by one in the future.

  2. Anonymous users2024-02-05

    The environment of the computer room monitored by the dynamic environment monitoring system is indispensable for the temperature, humidity and water leakage of the computer room, which are the main monitoring items;

    The dynamic environment monitoring system mainly monitors these six items.

    The first is the environment of the computer room, including the temperature and humidity of the computer room, water leakage, etc.;

    the second is the power of the computer room, including UPS power supply, switch, power distribution cabinet, etc.;

    the third is the computer room network, including servers, switches, etc.;

    fifth, fire protection, including smoke detectors, fire fighting equipment, etc.;

    Sixth, the alarm system of the computer room, including signal, sound and light, etc.

  3. Anonymous users2024-02-04

    Not exactly. Substation ** and environmental monitoring system, including cameras installed in various parts of the substation, temperature and humidity probes, wind speed probes, and may also include high-frequency anti-theft power grids or infrared radiation alarm systems. In addition to monitoring the temperature and humidity of the computer room, it is more important to monitor the power supply of the computer room.

  4. Anonymous users2024-02-03

    Monitor content. Environmental system: temperature and humidity, smoke sensor, mains power outage, water leakage, water immersion, etc.;

    Power system: UPS, air conditioning, current and voltage of municipal power distribution, three-phase fuel gauge, battery, fresh fan, generator, wind speed, etc.;

    Dynamic ring monitoring.

  5. Anonymous users2024-02-02

    The reporting type of the dynamic environment monitoring system.

    Telemetry collection and real-time monitoring of power equipment, computer room environment and security, and can record, save and process relevant data, detect faults, and realize intelligent monitoring and maintenance management of the security system, power system and environmental system of the computer room. In order to ensure the safety of the computer room, the personnel who can enter the computer room are managed by hierarchical authorization, and multiple computer rooms are unattended and remotely controlled.

  6. Anonymous users2024-02-01

    The full name of the dynamic environment monitoring system is the centralized monitoring and management system of power and environment of the communication bureau (station).

    Dynamic environment monitoring refers to the centralized monitoring of power equipment and environmental variables in various computer rooms.

  7. Anonymous users2024-01-31

    The dynamic environment monitoring system of the computer room is essentially a management system for monitoring the power system, environmental system, security access control and other equipment of the computer room, remotely monitoring the server, mains, fresh fan, battery, generator, air conditioner and other equipment, intelligently regulating the environmental system, and balancing the temperature and humidity of the computer room. When the temperature is too high, the voltage is unstable, and other problems occur, the system will automatically send out an alarm to remind the administrator to deal with it quickly.

    Dynamic ring monitoring. The equipment that constitutes the dynamic environment monitoring system of the computer room is divided into two parts: soft and hard, and the software part is a management cloud platform based on the Internet of Things system; Hardware devices include various types of perception sensors, alarm lights and other equipment, among which the detection sensors are:

    1. Mains monitoring module: mains is the main power supply of equipment in the computer room, and there are generally equipment such as head cabinets, distribution cabinets, and cabinet PDUs that need to be monitored to obtain voltage, current, power, frequency and other values;

    2. Remote power-off sensor: real-time voltage, current and other electrical parameter monitoring, remote alarm for power failure, incoming call, phase loss and other abnormal power supply conditions, inform the administrator in the form of ** and SMS, and quickly notify the power-off fault;

    3. Temperature and humidity sensor transmitter: the computer room has different levels and different requirements for temperature and humidity, and constant temperature and humidity are the prerequisites for ensuring the stable operation of network equipment and storage devices, so it is necessary to use the sensor to obtain the temperature and humidity information of the computer room, and the monitoring frequency is 1-5 minutes and can be adjusted;

    4. Access control equipment: fingerprint password all-in-one machine, magnetic lock, access control controller, human body sensor and other equipment;

    5. Battery detection module: The number of batteries used in the computer room is usually large, from more than ten to dozens of batteries, or even hundreds of sections, and the inspection module can be used to automatically check the resistance, voltage, temperature and other data;

    6. UPS detection module calendar block: use the protocol to connect with UPS power supply to realize UPS all-weather inspection and analysis;

    7. Flood alarm: responsible for monitoring the location of water accumulation in the computer room, the equipment has a built-in buzzer, and when water leakage is detected, the buzzer will sound to alarm;

    8. Air conditioning module: collect and analyze, operate control, fault alarm and other operations for ordinary and precision air conditioners, first-class air conditioning systems and other equipment;

    9. Smoke sensor: In order to detect the fire and celery accident in time, the smoke sensor needs to be deployed, and the equipment can detect it in the first time once there is smoke and smoke;

    There are also various types of sensing equipment such as vibration sensors, lightning protection monitoring modules, network cameras, relays, intelligent valves, etc., which are customized according to factors such as the scale of the computer room and the number of network equipment.

  8. Anonymous users2024-01-30

    A complete set of dynamic environment monitoring system in the computer room includes the following hardware equipment: dynamic environment monitoring host, temperature and humidity sensor, air conditioning controller, water leakage controller, water leakage induction rope, three-phase fuel gauge, smoke detector, infrared detector, power failure monitoring module, battery collection module, etc. Whether you need to be fully equipped and the number of equipment needs to be determined according to your needs and circumstances, you can search the official website of Anying Technology, and you can directly receive a personalized customization plan.

  9. Anonymous users2024-01-29

    Monitor the temperature of the computer room.

    Power communication. and other indicators are mostly used in unmanned computer rooms.

  10. Anonymous users2024-01-28

    The computer room monitoring system consists of a dynamic environment monitoring system solution integrating hardware and software.

    Hardware devices. <>

    System software.

  11. Anonymous users2024-01-27

    A lot of equipment is required, such as UPS, temperature and humidity, water leakage, and so on.

Related questions
6 answers2024-03-15

What we usually call ** signal, often refers to the analog ** signal, its recording method is generally analog tape recording, considering the signal attenuation of the video tape itself, with the increase of playback or copying, its image quality will also be irreparably degraded.

6 answers2024-03-15

What is remote monitoring.

Remote monitoring can be literally understood into two parts: "monitoring" and "control", of which "monitoring" is remote monitoring, which can be divided into two parts: one is the monitoring of the environment, the other is the monitoring of computer systems and network equipment, in any case, remote monitoring refers to the information obtained through the network: and "control" refers to remote control, refers to the method of operating the remote computer through the network, it not only includes the remote computer restart, shutdown and other operations, It also includes the day-to-day setup of the remote computer. >>>More

3 answers2024-03-15

The operation steps of public opinion monitoring are data capture, data analysis, and real-time data monitoring. >>>More

9 answers2024-03-15

The front end of the TV monitoring system is composed of cameras, lenses, PTZ, decoders, infrared lights, brackets, shields and other parts, and the transmission part is composed of coaxial cables, control lines, power cables, twisted pair transceivers, etc., while the terminal part is composed of hard disk recorders, monitors, matrices and other equipment >>>More

21 answers2024-03-15

It's simple, do you pay for it, I'll do it for you.