The atomizer does not fog out, what is the reason for Bang Lijian s?

Updated on number 2024-03-27
14 answers
  1. Anonymous users2024-02-07

    The reason why the atomizer does not fog out is because the atomizer is an auxiliary instrument for respiratory system diseases, it uses a high-efficiency oil-free piston compression pump to compress the air, the compressed air enters the air duct, through the fine holes in the atomization cup, the high-speed air flow formed passes through the liquid surface, generates negative pressure, and drives the liquid or other fluids to be sprayed together on the barrier plate, and the liquid splashes around under the high-speed impact so that the droplets become fine mist particles and spray out from the outlet pipe.

    At present, many people use household atomizers at home are compressed air atomizers, some people do not understand this kind of atomizer, in the process of use is not well maintained, after a period of time, it is found that the atomizer can run, but the atomizer does not fog out, can not work normally.

    Solution. The solution for the atomizer not to fog out is that the consumer first turns off the atomizer switch, pulls the air duct out of the atomizer body, and then turns on the atomizer switch, and uses his finger to close the air outlet hole connected to the air duct before.

    Whether there is a strong gas ejection from the pores, this process will not cause any harm to people.

    If there is a strong gas ejection from the hole, it means that the atomizer is working normally, and the problem of the atomizer not fogging may be on the air duct or atomization cup, and the consumer only needs to change to a new set of atomization accessory packages.

    If it is found that the air outlet hole only has a slight gas ejection or no gas ejection, the consumer will turn off the atomizer switch again, open the air inlet hole of the atomizer, take out the filter cotton inside, and turn on the atomizer switch again to confirm whether the air outlet hole of the atomizer has a strong gas ejection, if there is an explanation that the filter cotton is polluted and the air inlet hole is blocked, the consumer only needs to replace the filter cotton, if there is still only a slight gas ejection or no gas ejection, the consumer then observes whether the air inlet hole is blocked with the naked eyeIf there is no blockage, it means that it is an internal fault of the body, and the manufacturer needs to be repaired.

  2. Anonymous users2024-02-06

    When it is not atomized, first turn off the nebulizer switch, pull the catheter out of the nebulizer, and then turn on the nebulizer switch switch, and use your fingers to get close to the air outlet that was connected to the trachea before to see if there is a strong gas ejection from the air hole (this process will not cause any harm to the human body).

    If there is a strong gas ejection from the air outlet, it means that the nebulizer is working normally, and the problem of the nebulizer not fogging may be on the conduit or nebulizer cup, which needs to be replaced.

    If there is only a slight gas ejection or no gas ejection from the air outlet, turn off the switch again, open the air inlet hole of the atomizer, take out the filter cotton inside, turn on the switch again, confirm whether there is a strong gas injection from the air outlet hole of the atomizer, if there is obviously a filter cotton is polluted, replace the filter cotton, if there is still no change, observe whether the air inlet hole is blocked, and clean up the blockage, if not, it is an internal problem of the body, and it needs to be repaired.

  3. Anonymous users2024-02-05

    If the atomizer does not fog, you need to check the air inlet or air outlet, and clean it if it is blocked. This kind of stomatal blockage is often caused by the filter cotton of the air inlet hole being used for too long and too much ash layer.

  4. Anonymous users2024-02-04

    1.The first step should be to check whether the power supply is on;

    2.If there is no problem with the power supply, it is more troublesome and needs further maintenance, it is recommended to contact the merchant for after-sales, if it is a professional, you can open the machine yourself for inspection and troubleshooting.

    Press the on/off button, but the machine does not fog out or the fog is very small.

    1.Pull out the air duct first, and feel the air outlet with your hand to see if there is air flow coming out, or if the air flow is small.

    2.If it is, it may be that the air inlet or outlet hole is blocked, if the blockage is found after inspection, it can be cleaned up, this air hole blockage is commonly caused by the use of the filter cotton of the air inlet hole for too long and too much gray layer.

    3.If it is not blocked by the air hole, it may be a problem with the compression pump of the atomizer, it is recommended to contact the after-sales service, if the air outlet of the air hole is normal, then check whether there are water droplets in the air duct, whether the atomization cup is installed correctly, and whether the air guide pipe and the atomization cup are broken or the connection is not normal.

    After the atomizer is turned on, the fogging is normal, but the noise is louder than usual, and the vibration is intensified.

    1.Start by shutting down the machine and do a full inspection of the machine. You can take the machine and shake it gently, try whether there is a loose phenomenon inside the machine, if so, it is recommended to deal with it after sale, if there is no problem, check whether the air inlet is put into the filter cotton, whether the machine is placed smoothly, and the atomizer shock-absorbing foot pad is normal.

    There are also some reasons that the atomization cup plugs the vents with some liquid residues, resulting in no airflow, and there will be no fogging.

    You can take a look at it, I hope it will help you

  5. Anonymous users2024-02-03

    The reason why the atomizer does not fog out and its solution.

    Reason 1: Turn on the switch, the atomizer does not work.

    Solution: should check whether the power supply is connected, if there is no problem with the power supply, it is more troublesome, further maintenance is needed, it is recommended to contact the merchant for after-sales, if it is a professional, you can open the machine yourself for inspection and troubleshooting.

    Reason 2: Turn on the switch, the machine can work normally, but there is no fog or the fog is very small.

    Solution: Unplug the air duct and feel whether there is air flow coming out of the air outlet hole with your hand, or if the air flow is small. If so, it may be a blockage of the air inlet or air outlet, and if it is found to be blocked, it can be cleaned up.

    If the porosity is normal, it may be a problem with the compression pump of the atomizer, contact the after-sales service. If the air outlet from the air hole is normal, then check whether there are water droplets in the air duct and whether the atomizing cup is installed correctly.

  6. Anonymous users2024-02-02

    The use of this compressed air nebulizer is as follows: first open the nebulizer cup, pour an appropriate amount of medicine into the nebulizer cup, do not exceed the maximum solution volume of the atomizer cup is 6ml, cover the atomizer cup and tighten it; Then connect the mouthpiece or atomization mask, atomization cup and air pipe in turn, and check whether the filter cotton is placed in the main machine; Then connect the power supply of the host, turn on the power switch, wait for the host to work normally for 1-2 minutes, connect the empty chain disturbance trachea between the spray port of the host and the atomization cup, and use a mouthpiece or wear an atomization mask for atomization**; Finally, after the liquid medicine is used up, stop**, unplug the air pipe and turn it off. When using, pay attention to the shed

    Before use, check whether the machine is installed, and do not stack warm or hot water in the atomizing cup. The inhalation time of each atomization should not exceed 20 minutes, and the liquid should not exceed 6 ml. Use the nebulizer continuously, at intervals of 30 minutes, and disinfect it at the end of the day.

    When the liquid medicine is stored in the nebulizer, do not handle or store the product.

  7. Anonymous users2024-02-01

    There are two reasons why the atomizer does not fog out: one is to check whether the fan is blowing outward, and the other is to check whether the atomizer is working.

  8. Anonymous users2024-01-31

    1.Look at miscibility. After adding the defoamer to the product, stir and observe the speed of miscibility to observe whether the miscibility is good or not.

    Poor miscibility can affect the product. 2.Look at the defoamer defoaming time.

    As a defoamer, it is necessary to have good defoaming and defoaming performance, and it is also one of the basic requirements. We can add the same amount of water-based defoamer to the same foaming system, and observe its defoaming speed and time to judge the quality of the water-based defoamer. 3.

    Look at the defoaming effect. After adding the defoamer, observe the defoaming speed. At the same dosage, the faster the defoaming speed, the better.

    4.See if the defoamer affects the quality of the product. Experiments can be conducted to see if water-based defoamers affect the system product.

    If it does not affect the system product, then it can be judged that the quality of the water-based defoamer is no problem in terms of returning to friends.

  9. Anonymous users2024-01-30

    In the process of using the humidifier, the failure of the humidifier does not fog occasionally occurs, especially the ultrasonic humidifier is the most prone to the failure of not starting the source of fogging, the ultrasonic humidifier does not fog out can not play the role of increasing indoor air humidity, why does the air humidifier not fog, what is the reason why the humidifier does not fog up? To know why the air humidifier does not fog, we must first understand the basic structure of the ultrasonic humidifier, the entire ultrasonic humidifier is mainly composed of power supply, oscillator, power amplification, transducer, water supply structure and fan, and each part has a specific role. 【Click**View more related content】The oscillation circuit of ultrasonic humidifier includes power supply circuit, bias circuit, oscillation circuit and control circuit.

    The ultrasonic humidifier increases humidity to the air, and its work is to rely on the "ultrasonic transducer" device in the humidifier, which is a "piezoelectric ceramic crystal", similar to the piezoelectric ceramic sheet in the piezoelectric buzzer, but its natural frequency is much higher than that of the buzzer. 【Click**To see more related content】The phenomenon of non-fogging of humidifiers is a more common phenomenon, and there are no more than the following two reasons for this phenomenon: the reason why the humidifier does not fog is cautious, and in the process of use, the humidifier does not fog out, to check whether the power supply of the fan is normal, whether the electrical components are damaged, and whether the wind is damaged.

    2. Lack of regular maintenance of the humidifier, in the process of long-term use, a large amount of scale is formed on the atomizer sheet immersed in water during work, resulting in the atomizer can not operate normally, and finally the humidifier has less fog or the humidifier does not fog out. In this case, you only need to replace the atomizer sheet and maintain it regularly during future use, so that the humidifier will not fog out for this reason. Maintenance Method:

    The humidifier uses purified water, and it should be replaced once a day, and it should be cleaned once a week, and tap water is generally not used to add to the humidifier. 【Click**To see more related content】The above two reasons why the humidifier does not fog up are the two main factors, which can be detected with only a simple tool, which is DIY repair by hand, and it is also a very simple thing, if it is not for the above two reasons, then it is best to find a manufacturer to repair. What is the recommended air humidifier principle?

    What brand of humidifier is good?

  10. Anonymous users2024-01-29

    Maybe the atomizer is broken. The nebulizer is not corrosion-resistant, and if the liquid comes into contact with the nebulizer sink, the Shixing nebulizer will cause damage to the nebulizer sun-limb piece.

    It is recommended to remove it yourself and replace it with an atomizer tablet to install it.

    You can ask the manufacturer if they sell them and where to buy them.

    Or ** also has it on the **.

  11. Anonymous users2024-01-28

    1. It is very likely that the atomization module of the spray is broken.

    2. Another reason is that the water in the tank is too much or too little.

    3. There is a black probe on both sides of the atomization module, add water to the water level and the same position as the black probe, and the spray effect is the best, the water level will not be foggy or the fog volume is small if the water level exceeds or is lower than the black probe.

    4. Check if there is a large amount of scale on the atomizer, which causes the atomizer to not work properly.

  12. Anonymous users2024-01-27

    See if the partition of the atomizing cup is not properly placed? Take H&H Little Prince atomizer as an example:

    The atomization cup in the atomization kit, there is a partition inside, which is set on the atomization cup spray hole, only two are combined to be able to atomize normally, if you forget to put it after cleaning, or the position is a little deviation, the effect of atomization will be affected!

  13. Anonymous users2024-01-26

    The wattage is not in place, or the atomizer is condensing.

  14. Anonymous users2024-01-25

    See if the partition of the atomizing cup is not properly placed? Take H&H Little Prince atomizer as an example: the atomization cup in the atomization kit has a partition inside, which is set on the atomization cup nozzle, and only two can be atomized normally if they are combined.

Related questions
14 answers2024-03-27

There are two most common nebulizers on the market: one is ultrasonic, and the second is air-compressed. The ultrasonic atomizer uses electronic high-frequency oscillation through the principle of ultrasonic, and the high-frequency resonance of the atomizer sheet produces elegant fog-like particles. >>>More

5 answers2024-03-27

My friend started with the brand of Parry, he said that although there are all kinds of atomizers, but it is more reliable to start with a regular one, I heard him say that Parry has been making atomizers for more than 100 years, and the quality is still very guaranteed, mainly after the effect is done, it is still obvious, you can go to understand, I hope my answer can help you.

5 answers2024-03-27

Here's how to make a simple atomizer at home: >>>More

16 answers2024-03-27

I have a Compact atomizer from Pari at home, and I think it's reliable and I can afford it. Many people think that I am hot-headed, in fact, at this special time at home, it is really necessary to prepare a nebulizer at home, like my family is the boss's physique, old cold, seven or eight times out of ten colds will pant, it has to be atomized, not atomized gasping is scary, I dare not sleep at night, it is too troublesome to run the hospital, you can atomize at home, you can easily do it without running the hospital, isn't it good?! The doctor heard me say that I should have an atomizer at home, and he also said that it was okay and then recommended the PARI compact atomizer to me, saying that PARI is the leader of the atomizer, and the brand history is more than 100 years. >>>More

31 answers2024-03-27

It should be that the internal wiring is in poor contact.