The principle of comfortable dehumidification operation of the swimming pool heat pump unit is to remove the moisture of the indoor hot and humid air through refrigeration, and release the heat absorbed during dehumidification into the water of the swimming pool to realize the recycling of damp heat.
-
At present, swimming pool dehumidifiers are mainly divided into three types: air-cooled, water-cooled, and liquid dehumidification and air-conditioning systems. The air-cooled dehumidifier is a type of air dehumidification in which the welding value decreases first and then rises; The water-cooled dehumidifier uses condensation heat to heat the swimming pool water, which is an environmentally friendly dehumidifier that uses waste heat; The liquid dehumidification air conditioning cooling system belongs to the air enthalpy dehumidification process, and its realization principle is that the high concentration of lithium bromide and other salt solutions fully absorb the moisture of the indoor air, and evaporate the dilute solution water into a concentrated solution through the pipeline to the outside to return to the room to absorb water, so that the cycle repeats and gradually reduces the humidity of the indoor air to the specified RH value, and the liquid air conditioning system dehumidifier avoids the damage caused by freon to the ozone layer, which is an environmentally friendly product.
To sum up, the dehumidifiers of the latter two are relatively low-carbon and are ideal for swimming pool dehumidifiers.
-
The swimming pool constant temperature dehumidification unit and dehumidification cabinet adopt the principle of heat pump technology to dehumidify the indoor swimming pool environment by absorbing the heat in the indoor swimming pool air, and the air heat exchanger of the outdoor unit discharges the condensation waste heat to the outdoors to achieve independent dehumidification operation.
-
It belongs to the principle of air conditioning and refrigeration, and the heat of the first is used for the constant temperature of the pool water, which is very energy-saving
-
Refrigeration capacity is to make the temperature of a space or object lower than the surrounding ambient temperature, and keep in the specified low temperature state of a science and technology, Carnot cycle principle, air volume may be circulating air volume and fresh air volume, circulating air volume refers to the amount of air filtration, fresh air volume refers to the amount of fresh air damper control.
The amount of water vapor that coexists in moist air at the same time as lkg of dry air is called moisture content. Dehumidification capacity refers to the amount of moisture removed per hour.
-
The working principle of the swimming pool constant temperature dehumidification heat pump unit is the refrigeration principle, but it adopts the refrigeration principle of full heat ** technology, which can use the condensation heat to heat the pool water and indoor air.
-
Same as the principle of air conditioning, the swimming pool constant temperature dehumidification heat pump uses an air source to absorb the heat of indoor air, condensate and dehumidify, and the heat of dehumidification heats the pool water, and so on.
-
As a principle, the dehumidification heat pump is the best swimming pool hot and humid air, the dehumidification process of air moisture condensation releases latent heat and air temperature reduction humidity heat through the compressor and other compression workmanship to high-grade heat energy, swimming pool equipment in winter will be used to heat the water to maintain the temperature of the pool water, part of the heat is used to heat the low temperature air after dehumidification, through the dehumidification heat pump can maintain the indoor air temperature, humidity and pool water temperature.
-
Airflow circulation process: indoor air, air duct return air outlet, return air pipe, static pressure box, dehumidification heat pump unit, exhaust air (dirty and humid air is discharged to the outside), fresh air and return air mixing, refrigeration and dehumidification, heating, air supply, static pressure box, air supply pipe, air supply indoor.
-
The working principle of the swimming pool constant temperature dehumidification heat pump is to use the heat loss of evaporation on the surface of the pool water and transfer it to the pool water and air to meet the heat required for pool water and air insulation. First of all, the warm and moist air flows through the evaporator, the temperature drops, and the warm water vapor condenses into cold water and separates it from the air, so that the air is dry and the air dehumidification function is realized. The heat energy released during air cooling, water vapor condensation and cooling is absorbed by the refrigerant. In the second step, the high-temperature refrigerant absorbs the heat energy and heats the pool water through the heat exchanger to realize the heating function of the pool water; The other part of the heat passes through the reheater to heat the cooled indoor air to realize the heating function of the air.
-
The evaporated heat loss in the swimming pool is transferred to the pool water and air to make up for the heat loss of the pool water and air and achieve the purpose of dehumidification.
-
The unit will detect whether there is a need for auxiliary cooling or heating, and then the unit will give a signal to control the external solenoid two-way valve, and control the auxiliary refrigeration heating meter cooler to pass hot and cold water.
-
First, the condenser should be cleaned frequently and kept clean. The dehumidifier should be placed indoors**. There shall be no obstructions in the air outlet of the dehumidifier, and the air filter should be cleaned.
Second, when the temperature is lower than 15, the water droplets attached to the surface of the evaporator will freeze and weaken the effect of the dehumidifier, if the temperature exceeds 40, the pressure in the system will increase and overload the compressor, at this time the overload maintainer should cut off the line, otherwise the motor of the compressor will be damaged.
-
Dehumidification heat pump is the best swimming pool hot and humid air, dehumidification process air moisture condensation release latent heat and air temperature reduction damp heat through compressor compression workmanship to high-grade heat energy, swimming pool equipment in winter will be part of the heat used to heat the water to maintain the temperature of the pool water, part of the heat is used to heat the dehumidified low temperature air, through the dehumidification heat pump can maintain the indoor air temperature, humidity and pool water temperature.
The difference between the two is mainly in the use environment, in the swimming pool, because the pool level often needs to be disinfected, the disinfection will produce chlorine, and chlorine is corrosive. Therefore, the equipment used in swimming pools needs to have anti-corrosion function, and the special swimming pool dehumidification heat pump has anti-corrosion treatment, and most industrial dehumidifiers do not. Recommend the parkoo dehumidifier. >>>More
When the air conditioner runs the refrigeration mode, it is necessary to remove the water vapor at the same time as the air temperature is reduced, and the temperature and wind speed of the refrigeration can be increased or lowered. The air conditioner operates in cooling mode according to the temperature and wind speed you set, which aims to reduce the air temperature in the room (and at the same time expel condensate), and the cold air blowing is relatively strong. >>>More
The dehumidification mode is purely calculated based on the length of use, and the dehumidification mode of the air conditioner is more energy-saving than the refrigeration mode. Dehumidification modeThe dehumidification mode mainly liquefies the water vapor in the indoor air at home into condensate and discharges it outdoor, which will also reduce the indoor temperature, and the advantage of the dehumidification mode is that the indoor temperature is relatively stable after it is lowered, and the indoor humidity is less, so as to become cooler. Refrigeration mode increases power consumption, we turn on the dehumidification mode, the outdoor unit of the air conditioner is to maintain a low speed operation, the compressor is also intermittent operation, in this case, the indoor temperature can be kept near the set temperature, and a large amount of indoor moisture can be removed, when the refrigeration mode is turned on, the outdoor unit and the compressor of the air conditioner will remain in a state of continuous operation, and stop operating after the room temperature reaches the set temperature, which greatly increases the power consumption. >>>More
The lower the room temperature, the longer the evaporator surface is at a low temperature, which can achieve the purpose of power saving. But if the room temperature is too high, it won't work. It doesn't take long for the evaporator to heat up, causing the compressor to start up frequently or stop at all. >>>More
Use the refrigeration mode to set the temperature a little higher, the higher the more power saving. >>>More