  1. Anonymous users2024-02-07

    The landlord means that the recovery of the scales is not good. It stands to reason that the grain should be taken and 0 should be displayed. But the display is negative.

    This may be due to the poor rigidity of the mounting position when the weigh module is installed, or the connection between the scale and the external equipment is hard or soft.

    When you clear the zero, it is to readjust the zero position of the scale, which has nothing to do with the weighing of the scale. For example, if your scale shows -70kg, if you put 100kg, it will show 30kg. And if you clear it and put 100kg, it will show 100kg.

    So as long as your scale is standard, then how much should be put after zeroing. The recovery of the scale is not good, it is a problem with the mechanical parts of the scale, and it is recommended that the landlord check it.

  2. Anonymous users2024-02-06

    Clearing is to define the weight of the scale as zero at this time under the condition of the current empty bucket.

    After the landlord clears the zero, if there is 10t of grain in the next bucket, it shows that it should be 10t, and the total cumulative amount is 10t.

  3. Anonymous users2024-02-05

    Clearing is to let the scale think that you are empty at this time and the scale has zero weight, as long as the calibration is no problem, the next time you use 10t, it will also show 10t. There is zero drift when used for a long time.

  4. Anonymous users2024-02-04

    10t, clearing is to treat the current weighing state as no load...

  5. Anonymous users2024-02-03

    Summary. Hello dear, it is a pleasure to serve you <>

    Through the data query display, please check 1, check whether the output signal value of the electronic scale sensor is within the standard, if not, then repair; 2. Enter the function setting of the electronic scale to see if it is caused by the setting of the automatic zero range is too small. Most of the cases caused by the non-zero failure of the electronic scale are caused by the sensor, so the maintenance of the sensor should be done daily. The connecting bolts of the sensor should be protected against rust, such as lubricating oil and adding protective sleeves.

    Regularly check the looseness and rust of the connectors, and eliminate hidden dangers in time. If it is a column sensor, the rotation of the sensor body should be checked regularly, and the bridge sensor should check the return and lubrication of the steel ball.

    TOLEDO scales do not return to zero.

    Hello dear, it is a pleasure to serve you <>

    Through the data query display, please check the draft imitation check 1, check whether the output signal value of the electronic scale sensor is in the standard, if not, then repair; 2. Enter the function setting of the electronic scale to see if it is caused by the setting of the automatic zero range is too small. Most of the cases caused by the non-zero failure of the electronic scale are caused by the sensor, so the maintenance of the sensor should be done daily. The connecting bolts of the sensor should be protected against rust, such as lubricating oil and adding protective binding.

    Regularly check the looseness and rust of the connectors, and eliminate hidden dangers in time. If it is a column sensor, the rotation of the sensor body should be checked regularly, and the bridge sensor should check the return and lubrication of the steel ball.

    If you encounter the problem of not returning to zero when booting up, it may be caused by the setting of the zero range is too small, or it may be that there are objects left on the weighing pan, so check whether there are any items on the weighing pan and whether the setting of the zero range is reasonable. 2.Unable to backlight, generally because the battery is low or the weight of the weighing item is too small, so you can first check whether the weight of the item meets the weighing range, if it meets the range, check whether the battery is sufficient.

    3.The electronic scale does not display the value, it is likely that the battery level is not fully equipped and automatically shut down or the fuse is burned, so you only need to check whether the battery level and fuse are intact. 4.

    If you encounter a situation where you cannot charge, you need to check whether the fuse is blowing.

  6. Anonymous users2024-02-02

    Summary. According to the problem you inquire, the common TOLEDO scale faults are: abnormal display of the electronic scale, problems with the accuracy of the electronic scale, failure of the electronic scale to normal weight and calibration, etc.

    Display error252

    According to the questions you inquire, the common TOLEDO electronic scale failures are: abnormal display of the electronic scale, problems with the accuracy of the electronic scale, and the inability of the electronic scale to have normal weight and calibration.

    Dear Hello error252 is a failure of the electronic scale display, you can try to restart the electronic scale, if the problem still exists, please contact Toledo's customer service or technical personnel to assist in solving the problem of Xiaoheng wheel.

    <> pro

    Error 252 is a common error that is usually caused by a malfunctioning sensor on a scale or a problem with the internal components of the scale. To solve this problem, you can try the following steps:1

    Check the sensor on the scale to see if there are any damaged or loose parts. 2.Check the connectors on the scale to see if there are any loose or broken parts of Lu Xiaoyan.

    3.Check the internal components of the scale to see if there are any damaged or loose parts of the socks. 4.

    Try to reinstall all the connectors and components on the scale and check that they are working properly. 5.If all steps fail to resolve the issue, you may need to send your scale to the manufacturer for repair or replacement.

  7. Anonymous users2024-02-01

    Pro, TOLEDO electronic scale is a common electronic scale brand, the following are some common faults and solutions that may be encountered:1The scale does not turn on or does not respond:

    First check if the battery is charged or replaced. If you're using a power adapter for power, check that the power cord is connected correctly. At the same time, make sure that the interface is clean and free of dirt or oxidation.

    2.The display is garbled or won't be displayed: Check the display for scratches, clean the display and make sure it's well connected.

    In the meantime, try restarting the scale or performing a system recovery operation. 3.Heavy grip makes the volcanic volume inaccurate or unstable:

    Make sure the platform is flat and free of debris or foreign objects. Check the weighing pan for damage or looseness. If there are adjustable foot pads on the scale, adjust the foot pads to ensure stability.

    4.Button malfunction or slow key response: Check the key area for dust or dirt and wipe it gently with a detergent.

    Try carrying the recalibration button or restarting the scale. 5.Displays Error** or Alarm:

    Consult the operator's manual of the electronic scale to find the corresponding fault and solution according to the error** or alarm information. 6.Communication failures or connectivity issues:

    If the scale is connected to other devices through the communication interface, make sure that the connection line is normal and the interface is clean and undamaged. Check whether the communication parameters are set correctly. If you encounter any of these issues, it is recommended to try simple troubleshooting methods such as restarting the scale, replacing the battery, or making sure the connection is good.

    If the problem persists, it is recommended to contact the TOLEDO Service Center for professional support and solutions.

  8. Anonymous users2024-01-31

    Summary. Solution 1: Crash: Poor contact between the customer display and the pole wiring harness plug; Workaround:

    Change the wiring harness. 2. NIC interference: Method A:

    Unplug the network cable B: When unplugging the network card printer, there is an abnormal label printing blank. Abnormal labels with black or partially thick dark stripes, check the print head or printing cable, if there is a problem.

    Replace it. 3. When printing, the paper is not smooth or can not be accurate: press the paper key of the keyboard to let the scale automatically move the paper, adjust the position, if the paper is still not good, enter the technical service menu to re-measure the paper.

    4. The sensor causes all kinds of weighing problems to recalibrate the scale: the weighing is unstable or inaccurate or there is an error to check whether the scale is level, whether there are foreign objects around, whether it is in the tuyere, if there is any of the above conditions, it will be cleared, shut down and restarted once, and the scale can be recalibrated with weights if necessary. 5. There is no response when the machine is turned on, and there is no sound on the buttons, but the fuse and the power supply at the beginning are normal, and the main PCB board must be replaced.

    6. The boot buzzer responds, and the buttons also have sound, but there is no display. Replace the display board or display harness. 7. There is no display when the power is turned on, there is no display sound, and the buttons do not respond.

    Check the fuse and switching power supply and replace it if there is a problem.

    Hello, I'm glad to answer for you Toledo electronic scale fault summary: 1. Electronic scale crash 2. Network card interference 3. Poor or inaccurate paper movement when printing Fourth, sensors cause various weighing problems and need to re-calibrate Chaqin scales 5. Boot without ruler reflection 6. Defeat Jane after boot boot without any display 7. Boot without any display.

    Solution 1: Crash: Poor contact posture of the plug of the guest display and the pole harness; Solution: Change the wiring harness.

    2. Network card interference: Method A: Unplug the network cable B:

    Unplug the network card When the printer is unplugged, the label is printed blank. Abnormal labels with black or partially thick dark stripes, check the print head or printing cable, if there is a problem. Replace it.

    3. When printing, the paper is not smooth or can not be accurate: press the paper key of the keyboard family source to let the scale automatically move the paper, adjust the position, if the paper is still not good, enter the technical service menu to re-measure the paper. 4. The sensor causes all kinds of weighing problems and recalibrates the scale

    The weighing is unstable or inaccurate or there is an error to check whether the scale is level, whether there are foreign objects around, whether it is in the tuyere, if there is the above situation, it will be cleared, shut down and restarted once, and if necessary, the scale can be recalibrated with a weight. 5. There is no response when the machine is turned on, and there is no sound on the buttons, but the fuse and the power supply at the beginning are normal, and the main PCB board must be replaced. 6. The boot buzzer responds, and the buttons also have sound, but there is no display.

    Replace the display board or display harness. 7. There is no display when the power is turned on, there is no display sound, and the buttons do not respond. Check the fuse and switching power supply and replace it if there is a problem.

  9. Anonymous users2024-01-30

    Summary. Hello! Introduction to the common faults of TOLEDO electronic scales, TOLEDO electronic scales use problem 1:

    When weighing, the result is unstable, and the stability monitor prompt light does not disappear 1, the environment in which the TOLEDO electronic scale is placed is too poor to improve the environment2, the parameters of the TOLEDO electronic scale are incorrect, and the parameters of the TOLEDO electronic scale are set at the time of leaving the factory 3, and the body temperature of the hand left in the weighing room is minimized to minimize this human factor 4, the temperature of the weighed object is not isothermal with the TOLEDO electronic scale, and the weighed object is placed next to the TOLEDO electronic scale isothermal 5. The sample has water absorption, water discharge, electrostatic, magnetic and other characteristics with reference to overcome the above effects. to be able to weigh correctly.

    Hello! Introduction to the common faults of Toledo balance scales, Toledo electronic scales use problem 1: When weighing, the results are unstable, and the stability monitor prompt light does not disappear 1, the environment in which the TOLEDO electronic scale is placed is too poor to improve the environment 2, the parameters of the TOLEDO electronic scale are incorrect, the parameters of the TOLEDO electronic scale are set at the factory3, the body temperature of the hand left in the weighing room is minimized by the human factor 4, the temperature of the weighed object is not isothermal with the dust grip of the TOLEDO electronic scale, and the weighed object is placed next to the TOLEDO electronic scale isotherm 5, The sample has water absorption, water discharge, electrostatic, magnetic and other characteristics to overcome the above influences in order to weigh correctly.

    Pai Ban Qing. Use problem 2: The weighing result is obviously inaccurate 1, there is no tare back to 0 first peel back to 0, and then weigh 2, the electronic scale is not calibrated or the wrong external weight is used to calibrate and weigh before weighing, first perform correct calibration, and then weigh 3, the power supply voltage exceeds the correct working voltage range to take measures to stabilize the power supply voltage Use problem 3: Tare back to zero is not good, it is difficult to return to full 01, the electronic scale work surface is cushioned with a layer of shockproof eraser, no matter which reason is due to the fact that when the operating lever is pressed, the electronic balance has actually been vibrated 2, The scale table is not stable enough to remove the rubber layer.

    Place the electronic scale on the cement table or a stable workbench to use Problem 4: When the maximum weighing is not reached, there is a "--upper half) overweight standard method 1, exceeding the selected range for the dual range of AE240, and re-placing the range to the 200g level. 2. The calibration code has been placed on the weighing plate, pull the calibration push rod on the lower right side to the front end, reopen the banquet and recalibrate the electronic balance and use it after recalibration

    During the weighing process, the indicator light of the stability monitor is not lit 1, the sensitivity of the stability monitoring device has been set to "OFF", and the ASD of the stability monitor is set to 2

    Problem 6: The Qiming should not be placed in the weighing room 1, there is a layer of shockproof oak on the electronic scale workbench, no matter which reason is due to the fact that when the operating lever is pressed, the electronic balance has actually been vibrated 2, and the electronic scale workbench is not stable enough to remove the rubber layer. Place the scale on a cement table or a sturdy work bench.

    Hello! The above is an introduction to the common faults of TOLEDO electronic scales.

Related questions
6 answers2024-04-07

Dolly is a cloned sheep, but he's been dead for a long time. I don't know what you mean by Dolly!!

9 answers2024-04-07

Zero-pressure room"It was the original hotel room"Upgraded", that is, in the original room of the quality Simmons. >>>More

15 answers2024-04-07

SEL has been used in some models of the W126 series, S is the S class, E is the electronic fuel system (in those days, this thing was still relatively advanced, like Audi's current FSI system), L of course means extended (of course, there are also SE, not lengthened models). >>>More

5 answers2024-04-07

Regardless of the car brand, the dashboard displays snowflake lights, which have three meanings: first, the outdoor temperature is lower than 4 degrees Celsius, which plays a role in prompting; The second is that the car enters the snow mode; The third is that the outdoor temperature sensor of the car is damaged. >>>More

19 answers2024-04-07

The group exterminated the relatives. This is the end of samsara.