How to solve the problem that the newly bought Haier 186 liter refrigerator in Gome is not refrigera

Updated on technology 2024-04-15
13 answers
  1. Anonymous users2024-02-07

    Hello, thank you for asking the company.

    General refrigerator does not refrigerate the reason:

    1.The high-pressure output buffer pipe in the compressor is broken, or the screw fixing the tube is loose, resulting in the high-pressure pipe not exhausting, and the low-pressure pipe not suctioning, so although the compressor is running, it is not refrigerated.

    2.The refrigeration system leaks, the refrigerant is gone, and although the compressor is running, there is no refrigerant evaporation and heat absorption in the system, so the temperature in the refrigerator does not drop.

    3.The capillary is blocked, the refrigerant cannot enter the evaporator to evaporate and absorb heat, and the temperature in the refrigerator does not drop.

    Check whether the door crack of the refrigerator is intact, if there is a loophole, the cooling capacity of the refrigerator will run out, resulting in poor refrigeration effect of the refrigerator.

    If you can't overhaul it yourself, it is recommended to call after-sales service ** and find professional after-sales maintenance personnel to come to overhaul.

    You are welcome to ask the company questions again.

    We wish you a happy work life

  2. Anonymous users2024-02-06

    Contact Gome immediately, return the machine, and it can only be repaired after 7 days.

  3. Anonymous users2024-02-05

    You can contact Haier after-sales service for on-site inspection and maintenance.

  4. Anonymous users2024-02-04

    See the name clearly before posting.

  5. Anonymous users2024-02-03

    Dear, hello, I'm glad to answer for you, Haier 188 liter air-cooled two-door refrigerator refrigeration does not refrigerate the reasons and solutions: 1. Power supply problem If the Haier refrigerator is not refrigerated, you should not suspect the use problem or the quality of the refrigerator, but you should first check whether there is a problem with the power supply and see if the power connection is normal. Workaround:

    Open the door of the refrigerator and observe whether the light in the box is on, or use an electric pen to test whether the socket is powered on. Second, the compressor problem, if the Haier refrigerator is not refrigerated, another reason may be that the compressor is not working properly. The compressor will emit a slight and vibrating motor sound when working properly.

    It may be due to a break in the high-pressure output buffer pipe inside the compressor or a loosening of the fixing screws of the pipe. Solution: If the high-voltage output buffer tube is broken, it needs to be replaced in time; If the fixing screw is loose, then it is only necessary to re-tighten the fixing screw of the high-pressure buffer tube.

  6. Anonymous users2024-02-02

    If it is computer-controlled: it may be that the temperature sensor of the refrigerator room has detected a deviation, and the temperature detected by the sensor has reached the set temperature, so the valve body for the refrigerant in the refrigerator is turned off, so the refrigerator is not refrigerated.

    If it is mechanically controlled: now the mechanical temperature control is generally single-temperature double-controlled, that is, by controlling the switch of the refrigerator room thermostat, the switch of the compressor, the general single-temperature double-control refrigerator is designed before leaving the factory, when the refrigerator reaches 0-10 degrees, the freezer reaches below -18 degrees, and maintains the normal freezing effect, because the refrigerant is first through the freezer, after the refrigerant cools the freezer to -18 degrees, the food also enters the freezing effect, then the cooling of the refrigerator begins, When the cooling of the refrigerated room passes the setting gear of the thermostat, the switch of the compressor can be controlled, and then the normal operation of the refrigerator can be controlled, so 1. As the refrigerated evaporator said on the second floor is not firmly pasted, it is separated from the refrigeration liner, and the middle is air, and the thermal conductivity effect of the air is very poor, so the refrigerated room is not refrigerated; 2. The refrigerant leaks, causing the freezer to absorb heat after it cools down, and the refrigerant absorbs heat to saturation, so it will not absorb heat when it enters the refrigerator, and it looks like the refrigerator is not refrigerated!

  7. Anonymous users2024-02-01

    Here's why:

    1.The dry filter of the refrigeration system is slightly blocked, and the solenoid valve --- capillary system entering the freezer are not very smooth, resulting in insufficient refrigerant flow into the evaporator of the freezer.

    2.The lack of fluorine due to micro-leakage in the refrigeration system also leads to insufficient refrigerant flow into the evaporator of the freezer chamber, and the leakage point must be found and solved, and the fluoride can be used normally.

    3.If the compressor does not work around the clock, the freezer compartment may cause the refrigerant to reach the maximum refrigeration temperature. Most of this phenomenon occurs in air-cooled refrigerators.

    The reason is that the evaporator flower froster in the cold room is broken, which produces an ice blockage. It cannot be ruled out that the air cooling fan is broken, and there are too many items in the refrigerator to block the air outlet, causing poor cooling effect.

    If it helps you, I'll take it.

  8. Anonymous users2024-01-31

    Problems like yours are very common in air coolers, usually the cause of failure is that the small fan of the freezer is stuck in the ice, and the air duct and evaporator in the freezer are not full of ice, resulting in poor refrigeration effect, no compressor shutdown but high temperature in the freezer.

    Handling Action: Shut down! And fully defrost (it is best to remove the back cover of the freezer to defrost the air duct and evaporator), if you can't do a thorough defrost it can't be solved (at least a week to defrost by power failure and open door).

    Since the compressor is not working, check the thermal protector and if it is good, then the compressor hangs.

  9. Anonymous users2024-01-30

    Hello, thank you for asking the company.

    It is very likely that there is a problem with the compressor accessories, it is recommended to contact Haier after-sales service, find professional technicians to come to repair, after-sales **4006-999-999

    You are welcome to ask the company questions again.

    We wish you a happy work life

  10. Anonymous users2024-01-29

    Check if the refrigerant is not added enough.

  11. Anonymous users2024-01-28

    Landlord: If you buy the refrigerator first, please let it stand for 2-3 hours before turning on the electricity, and there is also a process for cooling the refrigerator. There are also the following points to note:

    1.First make sure the refrigerator is powered on properly;

    2.The two doors of refrigeration and freezing are closed tightly without leaking cold;

    3.The knob of the thermostat in the refrigerated room is set appropriately, and it can be set at 2-3 at present;

    4.Keep the refrigerator away from heat sources, and leave at least 10cm of ventilation space around it;

    5.Don't put too many ingredients in the refrigerator at one time;

    If the fault is still there after the above measures are investigated, please call Haier after-sales service in time: 4006-999-999 and the engineer will come to the door for maintenance.

    Best wishes! Looking forward to the praise! :)

  12. Anonymous users2024-01-27

    Check if the refrigerant is not added enough.

  13. Anonymous users2024-01-26

    Landlord: If you buy the refrigerator first, please let it stand for 2-3 hours before turning on the power. There are also the following points to note:

    First make sure the refrigerator is powered on properly;

    The two doors of refrigeration and freezing are closed tightly without leaking cold;

    The knob of the thermostat in the refrigerated room is set appropriately, and it can be set at 2-3 at present;

    Keep the refrigerator away from heat sources, and leave at least 10cm of ventilation space around it;

    Best wishes! Looking forward to the praise! :)

Related questions
3 answers2024-04-15

In Gome Electric, the position of assistant director is the deputy director of the store. >>>More

4 answers2024-04-15

Haier smart home experience store (Dongying smart home general distribution).

6 answers2024-04-15

Dear Lenovo users, when installing win7 on the computer with win8 pre-installed, you can no longer install the hard disk in the boot state, you can choose the system disc, u disk or mobile hard disk boot disk for installation, but you need to enter the bois to adjust the relevant settings before installation (see the link below for detailed settings), and you need to format all partitions, it is recommended that you back up all your data to avoid unnecessary losses, I don't know if it solves your problem. >>>More

16 answers2024-04-15

None of what you said is correct, follow my method, click on the Internet neighbor on the desktop, select right-click properties, and find the local connection. Select the right-click attribute, pull down, select Internet Protocol, double-click, select Use the following IP address, and fill in the subnet mask in the IP address to use the default. >>>More

11 answers2024-04-15

How to deal with the newly bought pen, it is recommended that you go to the encyclopedia to enter the two words of the pen, which is very good, I cut and paste the specific content for your reference. >>>More