The standard is different, hehe.
-
Legal analysis: The second-level qualification of fire protection can undertake the construction of the following construction projects: (1) industrial and civil construction projects with a height of less than 100 meters; (2) Structures with a height of less than 120 meters; (3) Single industrial and civil construction projects with a construction area of less than 40,000 square meters; (4) Construction projects with a single-span span of less than 39 meters.
It can undertake the construction of fire protection facilities such as building construction with a building height of 100 meters and below and a construction area of 50,000 square meters and below, flammable, combustible liquid and combustible gas production and storage devices.
Legal basis: Article 8 of the Fire Protection Law of the People's Republic of China Local people at all levels shall incorporate fire protection planning including fire safety layout, fire stations, fire water supply, fire communications, fire truck access, fire fighting equipment, etc. into urban and rural planning, and be responsible for organizing and implementing them.
-
What are the standards for fire protection buildings in the first and second grades.
1. The second-level fire protection building standards are as follows:
1) The main building components of the second-class fire-resistant grade building are non-combustible;
2) The fire resistance limit of the roof panel of the flat roof of the factory or warehouse shall not be less than 1h and 1h respectively;
3) The second-class fire-resistant building must be a steel structure roof truss or reinforced concrete structure;
4) For the newly designed house, the level should be determined according to the height and area of the building, and the combustion performance and fire resistance limit of the components should be designed according to the requirements of the level.
2. Legal basis: Article 8 of the Fire Protection Law of the People's Republic of China.
Local people at all levels shall incorporate fire protection planning including fire safety layout, fire stations, fire water supply, fire communications, fire truck access, fire fighting equipment, etc., into urban and rural planning, and be responsible for organizing and implementing them.
If the urban and rural fire safety layout does not meet the fire safety requirements, it shall be adjusted and improved; If the public fire-fighting facilities and fire-fighting equipment are insufficient or do not meet the actual needs, they shall be added, reconstructed, configured or technologically transformed.
2. What are the criteria for filing a case for the crime of fire protection liability accidents?
The criteria for filing a case for the crime of fire accident liability are as follows:
1. Causing the death of one or more people, or seriously injuring three or more people;
2. Causing direct economic losses of more than 500,000 yuan;
3. Causing forest fires;
4. Other circumstances that cause serious consequences.
-
Summary. What are the requirements for secondary fire protection, requirement 1: The main building components of secondary fire-resistant buildings must be non-combustible; Requirement 2:
For the roof of a factory or warehouse, the fire resistance limit of the roof panel should not be less than 1h and 1h respectively; Requirement 3: The second-class fire-resistant building must be a steel structure roof truss or reinforced concrete structure; Requirement 4: For the newly designed house, the level should be determined according to the height and area of the building, and the combustion performance and fire resistance limit of the components should be designed according to the requirements of the level.
What are the requirements for secondary fire protection, requirement 1: The main building components of secondary fire-resistant buildings must be non-combustible; Requirement 2: The fire resistance limit of the roof panel of the factory or warehouse should not be less than 1h and 1h respectively; Requirement 3:
The second-class fire-resistant building must be a steel structure roof truss or reinforced concrete structure; Requirement 4: For newly designed houses, Lao Chun should determine its level according to the height and area of the building, and design the combustion performance and fire resistance limit of the components according to the requirements of the level.
What is the thickness of the fire retardant coating for the secondary fire protection requirements of the steel structure.
Hello dear, the standard for the thickness of steel fire retardant coating is 23mm to 27mm, which is not millimeters.
Hello dear, it's 23mm to 27mm.
Legal analysis: 1. Disabled persons can enjoy free admission in parks in urban areas with the Certificate of Disabled Persons of the People's Republic of China, but not in some special scenic spots in the suburbs. 2. Take the train and plane, and give priority to ticket purchase and boarding. >>>More
The 2018 fire engineer examination is not limited to majors, any major can apply for the examination if the conditions are met, and obtain the corresponding fire engineer qualification certificate issued by the state, and the professional and technical personnel who can be engaged in fire protection facility testing, fire safety testing and other fire safety technology work with this certificate. >>>More
The difference between the first and second class registered fire engineers is mainly reflected in the following points: >>>More
The scope of practice of Class 1 and Class 2 registered fire protection engineers is different. >>>More
7. The three major abilities that an orator must have.