Elevators must be set up on several floors of public buildings, and there are no regulations on how

Updated on amusement 2024-05-06
10 answers
  1. Anonymous users2024-02-09

    The following high-rise buildings should be equipped with fire elevators:

    A class of public buildings. (Multi-storey buildings with more than 12 floors (according to the calculation of floor area) or 36 meters or more with a cornice height.)

    2. Single-storey buildings with a span of more than 24 meters or a cornice height of more than 18 meters.

    3. Equipped with double-decker cranes or industrial plants with crane lifting capacity of more than 50 tons.

    4. Steel and reinforced concrete frame structure, shear wall structure, frame-shear wall structure and simplified structure engineering with more than 10 floors.

    5. Structures with a height of more than 55 meters, or a diameter of more than 20 meters (the circumference of a single body of other shapes is more than 80 meters), or a single volume of more than 1,500 cubic meters in a pool (tank).

    6. Structures of steel or reinforced concrete structures with complex shapes such as spherical, elliptical, hyperbolic, conical and other shapes (not subject to the restrictions of paragraph 5 of this article).

    7. Buildings with a construction area of more than 30,000 square meters.

    8. Multi-storey buildings with a span of more than 24 meters and a construction area of more than 30 percent of the total construction area of the unit. )

    Tower dwellings. 12-storey and above units and corridors.

    Other Class II public buildings with a height of more than 32m.

    The number of fire elevators in high-rise buildings shall comply with the following provisions:

    When the construction area of each floor is not more than 1500m2, 1 unit should be set up.

    When it is greater than 1500m2 but not more than 4500m2, 2 units should be set up.

    When it is greater than 4500m2, 3 units should be set.

    The fire elevator can be used in conjunction with the passenger elevator or the working elevator, but it should meet the requirements of the fire elevator.

    The setting of the fire elevator shall comply with the following provisions:

    Fire elevators should be located in different fire zones.

    The fire elevator room shall be provided with a front room with its area; The residential building should not be less than ; Public buildings should not be less than; the area of the antechamber when shared with a smoke-proof stairwell; The residential building should not be less than ; Public buildings should not be smaller than 10m2.

    The front room of the fire elevator hall should be set up against the external wall, and an exit to the outside should be set up on the first floor or a passage with a length of no more than 30m to the outside.

    The door of the front room of the fire elevator hall shall be a Class B fire door or a fire shutter with a stagnation function.

    The load capacity of the fire elevator should not be less than 800kg.

    Between the fire elevator shaft, the machine room and other adjacent elevator shafts and machine rooms, the fire resistance limit should be used to separate the partition wall, and when the door is opened on the partition wall, a Class A fire door should be set up.

    The driving speed of the fire elevator shall be calculated and determined according to the running time from the first floor to the top floor not exceeding 60s.

    The interior decoration of the fire elevator car should be made of non-combustible materials.

    Power and control cables and wires should be waterproofed.

    There should be a special ** in the fire elevator car; And there should be a special operation button for firefighters on the first floor.

    Water stall facilities should be set up at the front room of the fire elevator room.

    Drainage facilities should be set at the bottom of the fire elevator, the capacity of the drainage well should not be less than, and the drainage capacity of the drainage pump should not be less than 10L s.

  2. Anonymous users2024-02-08

    It's not settled, as long as you have the money. Map.

    This data is ** on the map, and the final result is subject to the latest data on the map.

  3. Anonymous users2024-02-07

    There should be no less than two elevators in each building, and the reasons are as follows:

    In a narrow sense, high-rise refers to residential buildings with 12 floors or more, and elevators according to the "Residential Design Code".

    For residential buildings with 12 floors or more, there should be no less than two elevators in each building, and one elevator that can accommodate stretchers should be installed.

  4. Anonymous users2024-02-06

    Legal analysis: The residential building design code for buildings with more than seven floors stipulates that elevators shall be installed for residences with seven floors or more, or residences with the highest entrance floor and a height of more than 16m from the indoor ground floor on the ground floor.

    Legal basis: Article 6 of the "Residential Design Code" When one of the following situations is applied, an elevator must be set up:

    When the height of the entrance floor of a residential or residential building with seven or more floors exceeds 16 m from the outdoor design floor;

    When the floor of a residential building with six floors or less on the ground floor is used as a shop or other building, and the floor of the entrance floor of the tenant is more than 16 m from the designed outdoor ground level of the building;

    When the floor of a residential building with six floors or less on the ground floor is used as an overhead floor or storage space, and the floor height of the entrance floor of the household is more than 16 m from the outdoor design ground of the building;

    When the top floor is a two-storey duplex dwelling, the height of the entrance floor of the top floor is more than 16 m from the outdoor design ground of the building, regardless of the number of floors.

  5. Anonymous users2024-02-05

    The state stipulates that elevators need to be installed on the seventh floor and above of buildings.

    According to Article 6 of the "Residential Design Code", an elevator must be set up in one of the following situations:

    1. The height of the entrance floor of a residential or residential building with seven floors or more than seven floors is more than 16m from the outdoor design ground.

    2. For residential buildings with six floors or less on the ground floor as shops or other buildings, the floor of the entrance floor of the residential forest barricade is more than 16m away from the outdoor design ground of the building.

    3. For residential buildings with six floors or less than six floors on the ground floor as an overhead layer or storage space, the height of the entrance floor of the residential floor is more than 16m from the outdoor design ground of the building.

    4. When the top floor is a set of two floors, the number of floors is not counted, and the height of the entrance floor of the top floor of the building from the outdoor design ground of the building exceeds 12 floors and above the 12 floors of Weifan high-rise residences, and each building shall be equipped with no less than two elevators. Tower and corridor residential elevators should be arranged in groups. When there is only one elevator per unit of a unit-type dwelling, it should be connected by a corridor on the appropriate floor.

  6. Anonymous users2024-02-04

    The number of floors that need to be set up has a lot to do with the purpose of the building, and the scope of the too wide is not determined.

    However, according to China's "Mandatory Provisions of Engineering Construction Standards Lu Heng" on the mandatory standards for the installation of elevators in housing buildings, that is, residential buildings with seven floors or more or the entrance of the house must be equipped with elevators with a height of more than 16 meters from the outdoor design ground; Elevators should be set up in office buildings with six floors or more, buildings for the elderly with more than four floors, the height of the floor of the highest residential floor of the dormitory from the ground of the entrance floor is greater than 20 meters, and hospital outpatient buildings or ward buildings with four floors or more should be equipped with elevators.

    In daily life, most of the buildings have to start thinking about the elevator after the building reaches the 7th floor.

  7. Anonymous users2024-02-03

    The number of floors that need to be set up has a lot to do with the purpose of the building, and there is no definite range.

    However, according to China's "Mandatory Provisions on Engineering Construction Standards", there are mandatory standards for the installation of elevators in Luhengguan housing buildings, that is, residences with seven floors or more or residences with a height of more than 16 meters from the outdoor design ground at the entrance of the house are too wide, and elevators must be installed; Elevators should be set up in office buildings with six floors or more, buildings for the elderly with more than four floors, the height of the floor of the highest residential floor of the dormitory from the ground of the entrance floor is greater than 20 meters, and hospital outpatient buildings or ward buildings with four floors or more should be equipped with elevators.

    In daily life, most of the buildings should start to consider the problem of the elevator being done early after the building reaches the 7th floor.

  8. Anonymous users2024-02-02

    The number of floors that need to be set up has a lot to do with the purpose of the building, and there is no definite range of liquid barriers.

    However, according to the mandatory standards for the installation of elevators in housing buildings in China's "Mandatory Provisions on Engineering Construction Standards", that is, residences with seven floors or more or residences with a height of more than 16 meters from the outdoor design ground at the entrance floor of the house must be equipped with elevators; Elevators should be set up in office buildings with six floors or more, buildings with more than four floors for the elderly, the height of the floor of the highest residential floor of the dormitory from the ground of the entrance floor is greater than 20 meters, and hospital outpatient buildings or ward buildings with four or more floors of four floors.

    In daily life, most of the buildings have to start thinking about the problem of elevator trouble after reaching the 7th floor.

  9. Anonymous users2024-02-01

    Seven floors and above.

    There is a relevant provision in the Residential Design Return Hole Code: Residences with seven floors or more or the height of the entrance floor of the resident building with a height of more than 16 meters from the outdoor design ground must be equipped with an elevator.

    Note: For multi-storey dwellings with the ground floor used as shops or other buildings, an elevator must be installed when the entrance floor of the resident is more than 16m away from the outdoor design ground level of the building;

    For multi-storey dwellings with overhead floors or storage space on the ground floor, elevators must be installed when the entrance floor of the residents exceeds 16m from the outdoor ground height of the building;

    If the top floor is a two-storey house, the number of floors is not counted. When the height of the entrance floor of the residential floor of the front floor is not more than 16m from the outdoor design ground of the building, there is no elevator.

  10. Anonymous users2024-01-31

    Answer] Article 1 of the :d Design Standards for Office Buildings" (JGJ T 67-2019) stipulates that elevators shall be provided for office buildings with four floors or more or if the height of the building is more than 12m from the outdoor design ground.

Related questions
9 answers2024-05-06

Here are some of the well-known brands recognized in the valve industry, which are widely recognized and have a high reputation. While rankings may vary depending on time and market conditions, the following brands are generally considered to be among the top brands in the valve industry: >>>More

13 answers2024-05-06

Code for Fire Protection Design of Buildings for multi-storey public buildings. >>>More