If the flow rate is too small, it will cause the vibration of the pump and the pipeline, which will have a certain impact on the life of the pump.
If the pressure is small, it means that the flow rate is large, and the head of the pump is not so large.
The pressure at the outlet is controlled by the valve regulating the flow rate.
-
The pressure of the pressure gauge on the pipe is the pressure value indicated by the pressure gauge welded on the pipeline, the pressure at the outlet of the pump is too large, which may break through the weak connection on the pipeline, and more importantly, the next production link does not need so much pressure; If the pressure is too small, the fluid may not diverge, and thus the area that needs to be diverged cannot be reached. The adjustment pressure is mainly adjusted by the degree of control valve opening and closing by the electric actuator.
-
There is a relationship between pressure and flow.
The upstairs should not be too arbitrary.
The flow rate of the pump in the hydraulic system is smaller, and the time to reach pressure is relatively prolonged.
The pressure gauge on the pipe refers to the pressure value of the fluid inside the pipe.
-
Pressure has nothing to do with flow, don't mislead people on the first floor.
The pressure is determined according to the needs of the user, and the internal pressure of the machine with the pump needs to be consistent with the pressure of the pump as much as possible.
If the pressure is too small, it can be inconsistent with the pressure of the connecting part, affecting the overall flow rate.
There is a specific formula for calculating the pressure of the pump, which is available at the time of design.
I hope that those who don't know don't mislead the landlord.
-
The reason for the decrease in the outlet pressure of a centrifugal pump may be due to one or more of the following reasons:
1. Deviation from the working condition point to the large flow rate and low head: under normal circumstances, the centrifugal pump has the performance of continuous downward withdrawal, and the flow rate gradually increases with the decrease of the head. In the actual operation process, due to some reason, the back pressure of the pump is reduced, and the working point of the pump passively shifts with the curve of the device to the low head and large flow point, which will cause the head to decrease, in fact, this is caused by external factors such as the change of the device, and there is no special relationship with the pump itself.
At this time, it can be solved by increasing the back pressure of the pump, such as closing the point outlet valve.
2. The motor will reverse due to the wiring, and it is generally necessary to check whether the steering of the pump is correct before starting.
3. Rotation speed reduction: the important factors affecting the pump head are the outer diameter of the impeller and the speed of the pump, under the condition that other conditions remain unchanged, the pump head is proportional to the quadratic equation of speed, it can be seen that the impact of speed on the head is very large, so the reduction of pump speed will greatly affect the expiration head.
4. Cavitation at the inlet of the pump: if the suction inlet pressure of the pump is too low, lower than the saturated vapor pressure of the pumped medium, cavitation will be formed. At this time, it is necessary to check whether the inlet piping system is blocked or whether the opening of the inlet valve is too small, or to increase the level of the suction tank.
5. Internal leakage: The gap between the rotating part and the stationary part in Dangbei is too large, which will lead to internal leakage, which is reflected in the drop in discharge pressure of the pump. The pump should be opened for inspection and repaired or replaced with parts that caused excessive clearance.
6. Impeller flow channel blockage: If the impeller part of the flow channel is blocked, it will affect the workmanship of the impeller and cause the outlet pressure to drop. Therefore, it is necessary to dismantle the pump and check to remove foreign matter. To prevent the recurrence of this problem, a filter can be added before the pump inlet.
-
Insufficient pressure at the outlet of the pump may affect the normal operation of the system. Here are some suggestions to help you solve the problem of insufficient pressure at the outlet of your pump:
Check the operating status of the pump: Make sure that the pump is operating normally and that there is no abnormal noise or vibration. If there is an abnormality, find out the cause and deal with it.
Adjust the valve: Check the valve at the outlet of the pump to make sure it is fully open. If the valve is not fully open, adjust gradually to increase the outlet pressure.
Check the speed of the pump: Make sure that the speed of the pump is up to the rated value. If the speed is too low, check the motor and drive system and adjust to the correct speed.
Clear blockages: Check the pump's suction inlet, impeller, and outlet to make sure there are no blockages. If there is a blockage, clear it to restore normal pressure.
Check the pump for wear: Check the key components of the pump, such as impellers, seals, and bearings, for wear. If it is worn, replace the corresponding parts.
Check the suction pressure: Make sure the suction pressure of the pump is sufficient. Check suction pipes, filters, and fluid levels to ensure proper water supply.
Consider replacing the pump: If the pump does not match the needs of the system, it can result in insufficient outlet pressure. Re-evaluate system requirements and select the right pump.
Pump Running in Series: If the system head demand is high, consider running two or more pumps in series to increase the outlet pressure.
Inspect the pipeline: Check the delivery pipe for leaks or breakages, and if there is a problem, fix it.
Regular Maintenance: Ensure that the pump is regularly inspected and maintained to maintain its good performance.
-
If the outlet pressure of the pump is insufficient, the following measures can be taken:
1.Check whether the pump is operating normally, if the pump is faulty, it needs to be repaired or replaced in time.
2.Check if the inlet pipe is blocked or that the pipe is too small and needs to be cleaned or replaced.
3.Check if the outlet pipe is blocked or the pipe is too small and needs to be cleaned or replaced.
4.Check whether the water source is normal, such as whether the water level of the water source is too low, whether the water quality is poor, etc., and take corresponding measures.
5.Check whether the pump selection meets the actual needs, if not, you need to replace the appropriate pump.
6.Adjusting the outlet pressure of the pump can be achieved by adjusting the outlet valve of the pump or adjusting the speed of the pump.
In conclusion, there may be a variety of reasons for insufficient pressure at the outlet of the pump, which need to be investigated one by one. If the problem cannot be solved, it is recommended to contact a professional pump maintenance personnel for inspection and repair.
-
The absence of pressure may be due to the following conditions: 1. The diarrheal pressure of the pipeline may be caused by the leakage of a certain part of the pipeline, so that the system pressure decreases; At this point, you can close the outlet valve and check the pressure. 2. Lack of water, insufficient water source in the pipeline is also one of the reasons for insufficient pressure, at this time, the noise of the pump can be heard after starting, and the sound of gradually closing the outlet valve will gradually decrease.
3. Impeller corrosion or impeller mouth ring wear; 4. Judge the pressure gauge.
Whether it is normal or not. The inlet pressure is too low, which proves that the installation height is too high, which makes the pump susceptible to cavitation.
Reducing the installation height can increase the inlet pressure, and if the inlet pressure is too high, as long as it is not too high, it will not affect the use.
Add a regulating valve at the outlet of the pump to adjust the opening of the valve to adjust the outlet pressure of the pump;
A thin pipe is drawn from the outlet of the pump to the inlet of the pump, a regulating valve is installed on the pipe, and the outlet pressure of the pump is adjusted by adjusting the valve;
Frequency conversion control, through the frequency converter to adjust the speed of the pump, to adjust the outlet pressure of the pump;
A fluid coupler is installed between the motor and the pump, and the speed of the pump is adjusted by adjusting the fluid flow coupler to adjust the outlet pressure of the pump.
-
Hello, dear, it is an honor to answer this question for you, what are the factors that cause the poor family ridge due to the low outlet pressure of the pump? lThe reasons for the decrease in the pressure at the outlet of the pump may be due to the following reasons: 1. The pump impeller or pipeline, and pump chamber are blocked with stolen goods.
2. The pump impeller is damaged. 3. The resistance of the pump outlet is too small, and the flow rate is too vain and percolated. 4. The pump feeds gas and cannot bring the flow.
5. The pump motor is reversed. Please go into the spike and exclude hello, dear, thank you for your patience, I have helped you find the answer to the relevant questions, you check it out
-
This answer is unreasonable, the inlet and outlet pressures of the water pump are relatively independent, and there are different answers to the closed circulation system of the air conditioner that your pump uses, that is, the chilled water circulation system, or the open circulation system, that is, the cooling water circulation system.
If the above pump is in a closed system, no matter how much the inlet pressure is, the role of the pump is mainly to provide power to eliminate the resistance loss of the pipeline, if the resistance loss loss is 10 meters, the pump head has 10 meters to meet the circulation requirements, if you choose 32 meters pump head, the pump will be seriously large flow operation, overpower, motor heating, etc.
The inlet pressure and outlet pressure are relatively independent, and the total pressure is the sum of the two.
-
This is obviously not in place for the pump selection, 70 meters of horizontal distance of the vertical height of 7 meters Yang Cheng, 17 elbows equal to the vertical height of 17 meters Yang Cheng, according to the parameters you provide the original static pressure plus the pressurization of the pipeline pump should be able to reach 83 meters of Yang Cheng, 83 meters - 24 meters = 58 meters, and the flow rate of the pump you use is 100 square meters The power is 15kw motor, there may be a false standard component of power, it is recommended that you install a 100 caliber pipeline pump
-
I think it's because you have to pump the water 52m higher, and you have to overcome such a long pipeline and the pipe resistance brought by the elbow, which causes your pump head to be insufficient, and then the current will be exceeded, so it is recommended to change to a pump with a higher head.
-
Close the small outlet valve so that it is not overloaded.
-
Hello, the relationship between the target pressure at the outlet of the pump and the outlet pressure 1. The inlet pressure of the pump: refers to the water supply end of the pump, the liquid supply pressure in front of the impeller, which is measured by the pressure gauge installed at the front end of the impeller of the pump head. 2. Pump outlet pressure:
It refers to the output end of the pump, the water transfer pressure behind the impeller, which is measured by the pressure gauge installed at the back end of the impeller of the pump head. 3. Negative pressure phenomenon at the inlet of centrifugal water pump: When the impeller of the centrifugal pump rotates at high speed, a vacuum negative pressure belt will be generated around it, so the centrifugal pump has a certain suction capacity.
If the centrifugal pump pumps water from a point where the water level is lower than the impeller position, the inlet pressure of the pump is negative; Conversely, the centrifugal pump is filled with water from a position higher than the impeller, and the water is filled into the pump at positive pressure, and the inlet pressure is positive pressure. When the centrifugal pump is supplied by a closed water supply pipeline, the water supply pipeline itself has a certain water supply pressure, and the pump is in a state of irrigation; When there is insufficient or no water available in the water supply line, the inlet pressure gauge of the pump will point to zero, and the inlet of the pump may already be in a state of negative pressure. Centrifugal pumps working under negative pressure may cause "cavitation" of the impeller and damage the impeller.
According to the different uses of the pump, the design parameters of the centrifugal resistant pump are not the same, some pumps are allowed to pump water at low places, and some centrifugal pumps require the inlet to maintain a certain water supply pressure. The negative pressure generated by the impeller of the centrifugal pump can judge the working condition of the pump from two angles; On the one hand, the negative pressure reflects the pumping capacity of the pump, and on the other hand, the negative pressure reflects the water supply status of the pump. Notes:
"Negative pressure" is a relative concept, and the pressure is not based on zero and punctuality, but on a standard atmospheric pressure. Higher than the benchmark is called positive pressure, lower than the benchmark is negative pressure, and negative pressure is also called vacuum pressure.
-
The pump outlet target pressure and outlet pressure are two different pressures related to each other. The target pressure at the outlet of the pump is the desired pressure that the pump is designed to deliver at its outlet. This pressure is usually specified by the pump manufacturer and is usually determined by the application requirements.
On the other hand, the outlet pressure is the actual pressure measured at the outlet of the pump. This pressure can vary in a spurious state due to a variety of factors, including flow rate, system resistance, and the property of the pumped fluid. Ideally, the outlet pressure should be equal to or slightly higher than the target pressure at the outlet of the pump.
If the outlet pressure is lower than the target pressure, it may indicate that the pump is not operating efficiently and may need to be adjusted. Conversely, if the outlet pressure is significantly higher than the target pressure, the key breakout can damage the system or the pump itself. In summary, the relationship between the target pressure at the outlet of the pump and the outlet pressure of the roll is that the outlet pressure should ideally be equal to or slightly higher than the target pressure for optimal pump performance.
-
If the outlet pressure of a closed centrifugal pump is low, it may affect the performance of the pump and the normal operation of the system. Here are some suggested actions:
Check the speed of the pump: First, confirm that the speed of the pump has reached the rated value. If the speed of the pump is too low, it is necessary to check the drive motor and transmission for bending problems. Possible causes include insufficient motor output power, loose or damaged belts, etc.
Check the installation of the pump: Make sure the pump is installed correctly and matches the system. Check that the pipes are connected correctly, that the valves are fully open, that the pipes are blocked, etc. If you find a problem, please deal with it promptly.
Check the impeller of the pump: Check the impeller for wear, clogging, or damage. If the impeller is severely worn, it may need to be replaced with a new one. If the impeller is clogged, debris needs to be cleaned up.
Check the operating parameters of the pump: Confirm that the operating point of the pump is within the design range. If the operating point is too high or too low, it may be necessary to replace the matching pump or adjust the system parameters.
Check the inlet side: Check if the suction pressure of the pump is normal. If the suction pressure is too low, it may cause air to enter the pump and affect the outlet pressure. In addition, make sure that the suction pipe dust duct is not leaking, clogged or too long.
Check the seal of the pump: Check the shaft seal and mechanical seal of the pump for leaks. Leaks can lead to deterioration in pump performance and seals need to be repaired or replaced promptly.
Check System Resistance: Check if the resistance within the system is too large. Pipes that are too long, pipe diameters that are too small, too many elbows, etc., will increase the system resistance and affect the outlet pressure of the pump. If necessary, the piping layout can be re-planned to reduce system resistance.
When dealing with these issues, it is important to follow the fail-safe operation and maintenance manual of the pump to ensure safe and efficient operation. If the problem still cannot be resolved, it is recommended to contact the manufacturer of the pump or a professional repairer for inspection and repair.
You don't know much about the mechanical characteristics of high-pressure fans, high-pressure fans can't adjust the wind pressure, only the air volume, and the wind pressure is determined by the load. When the speed of the fan is maintained at a certain level, the wind pressure will be small when the load is large, and the wind pressure will be large when the load is small. It is commonly known as the roots blower to be strong when it is strong, and weak when it is weak. >>>More
Centrifugal pump. Outlet check valve.
Effect of damage on the pump]. >>>More
1. What is the reason for the insufficient pressure of the water pump? >>>More
What should I do if there is no pressure in high-pressure water? It is recommended that you go to a professional repair place to repair it.
If the bag is blocked, check whether the ash cleaning system or the bag is pasted.