  1. Anonymous users2024-02-10

    Guangdong Rongji Electromechanical Technology Co., Ltd. has held a long-term "inverter maintenance training", the training course is carried out with the theme of inverter maintenance, introducing some commonly used inverters, DC governors, servo systems, various types of board maintenance technology, etc., mainly exercising component-level maintenance capabilities, and at the same time in-depth introduction to the application principles of some products, through learning such maintenance technology, so that students can master the component-level maintenance technology of products, based on the industrial control industry can solve some practical problems in a timely manner.

    1. Inverter maintenance training object: personnel who have a certain electrician foundation or a certain household appliance maintenance foundation.

    2. Inverter maintenance training instructor: maintenance engineers with high theoretical level and rich engineering practice experience from the front line of maintenance.

    3. Inverter maintenance training methods:

    1. The principle of industrial control products is combined with maintenance and application.

    2. In order to ensure the learning quality of students, the courses are scientifically arranged, mainly for small and medium-sized classes, and the enrollment is limited.

    3. Pay attention to the exercise and training of industrial control thinking, and practice with lectures to ensure the learning quality of students.

    Fourth, the inverter maintenance training theme: inverter and other industrial control products component-level maintenance.

    5. Inverter maintenance training course setting:

    1. Concept and principle of inverter;

    2. Practical application operation and selection of inverter;

    3. On-site on-line maintenance and debugging of inverter;

    4. Overview of inverter maintenance;

    5. Common faults and repairs of inverters.

    6. Methods and skills of drawing circuit schematic diagrams.

    7. CPU board maintenance.

    8. Maintenance of the main circuit of the inverter.

    9. Replacement of common ICs and measurement and replacement of modules.

    10. Trigger plate maintenance.

    11. Maintenance of sensor circuits.

    12. Power strip maintenance.

    13. Precautions for maintenance of high-power inverter and how to debug its performance 14. How to use an electric soldering iron to desolder ICs, modules and other components.

    Fax: 020-37204173

  2. Anonymous users2024-02-09

    This is not available, you can go to the bookstore and find the relevant books.

  3. Anonymous users2024-02-08

    No. 6, Lane 56, Yanfan Street, Tiexi District, Shenyang City, Liaoning Province.

    The inverter maintenance and commissioning was established on August 15, 2005 at No. 6, Lane 56, Yanfan Street, Tiexi District, Shenyang City, Liaoning Province, passing through bus stops 236 and 125.

    The inverter is a power control device that applies power electronics technology to change the working power supply frequency of the motor to control the coarse motor and rotate at different speeds. The inverter is mainly composed of rectifier circuit, buffer circuit, filter circuit, inverter circuit and so on.

    1. Which school is better for inverter maintenance training?

    Yichang Mechanical and Electrical Engineering School, Hubei Province.

    Yichang Mechanical and Electrical Engineering School, Hubei Province.

    Tri-Rivers Vocational and Technical Education Center.

    Tianjin Mechanical and Electrical Vocational and Technical College.

    Liaoning Mechanical and Electrical Vocational and Technical College.

    Changde School of Finance and Economics.

    Hengshui Vocational and Technical College.

    Wuhan No. 1 Light Industry School.

    Huaihua Technical School in Hunan Province.

    Fujian Chemical Industry School.

    2. Inverter failure**.

    OCF: Inverter overcurrent fault.

    SCF: The inverter can display SCF1 (motor short circuit) according to the different degrees of short circuit; SCF2 (with impedance short circuit); SCF3 (short circuit to ground).

    OBF: Braking overspeed.

    OHF: Inverter overheating fault.

    o child f: motor overload failure.

    OPF: motor masking and phase loss fault.

    OSF: Inverter input overvoltage fault.

    SLF: Inverter communication failure.

    USF: Inverter voltage fault.

    PHF: Inverter input phase loss fault.

  4. Anonymous users2024-02-07

    1. Which school is better for inverter maintenance training?

    Yichang Mechanical and Electrical Engineering School, Hubei Province.

    Yichang Mechanical and Electrical Engineering School, Hubei Province.

    Tri-Rivers Vocational and Technical Education Center.

    Tianjin Mechanical and Electrical Vocational and Technical College.

    Liaoning Electromechanical Nianchang Vocational and Technical College is buried.

    Changde School of Finance and Economics.

    Hengshui Vocational and Technical College.

    Wuhan No. 1 Light Industry School.

    Huaihua Technical School in Hunan Province.

    Fujian Chemical Industry School.

    2. Inverter failure**.

    OCF: Inverter overcurrent fault.

    SCF: The inverter can display SCF1 (motor short circuit) according to the different degrees of short circuit; SCF2 (with impedance short circuit); SCF3 (short circuit to ground).

    OBF: Braking overspeed.

    OHF: Inverter overheating fault.

    o child f: motor overload failure.

    OPF: Motor Phase Loss Fault.

    OSF: Inverter input overvoltage fault.

    SLF: Inverter communication failure.

    USF: Inverter liquid collision voltage fault.

    PHF: Inverter input phase loss fault.

  5. Anonymous users2024-02-06

    Summary. The inverter online maintenance platform is a special maintenance service, which can effectively improve the efficiency and quality of maintenance compared with the traditional offline maintenance service. The inverter online maintenance platform is a technology platform that realizes remote diagnosis, control and maintenance services through a dedicated network connection.

    Through the platform, any staff member or customer can remotely control the inverter without leaving the house, and at the same time, they can also view the status of the equipment, operation history and other information to quickly diagnose faults and quickly schedule repair services. The remote maintenance service of the inverter can help customers quickly find faults and reduce the time and cost of offline repairs. In the inverter online maintenance platform, sensors and other monitoring instruments can collect the operating data of the inverter and send the data to the server, so as to realize remote control and monitoring.

    In addition, the platform also provides an alarm system to monitor the operating status of the inverter in real time, and can send an alarm in time when an abnormality is found, so that maintenance can be arranged in time. The online maintenance platform of the inverter can not only improve the efficiency of maintenance, but also monitor the operation status of the inverter in real time, help users quickly find faults, and quickly arrange maintenance services, so as to save a lot of maintenance costs. The use of this platform helps to improve customer satisfaction with logistics work, improve work efficiency, and provide a new solution for enterprises to achieve intelligent maintenance.

    Injection molding machine inverter repair.

    The online maintenance platform is a special maintenance service, which can effectively improve the efficiency and quality of maintenance compared with the traditional offline maintenance service. The inverter online maintenance platform is a technology platform that realizes remote diagnosis, control and maintenance services through a dedicated network connection. Through the platform, any staff member or customer can remotely control the inverter without leaving the house, and at the same time, they can also view the status of the equipment, operation history and other information to quickly diagnose faults and quickly schedule repair services.

    The remote maintenance service of the inverter can help customers quickly find faults and reduce the time and cost of offline repairs. In the inverter online maintenance platform, sensors and other monitoring instruments can collect the operating data of the inverter and send the data to the server, so as to realize remote control and monitoring. In addition, the platform also provides an alarm system to monitor the operating status of the inverter in real time, and can send an alarm in time when an abnormality is found, so that maintenance can be arranged in time.

    The online maintenance platform of the inverter can not only improve the efficiency of maintenance, but also monitor the operation status of the inverter in real time, help users quickly find faults, and quickly arrange maintenance services, so as to save a lot of maintenance costs. The use of this platform will help improve customer satisfaction with the logistics of liquid destruction, improve work efficiency, and provide a new solution for enterprises to achieve intelligent maintenance.

  6. Anonymous users2024-02-05

    Common faults and maintenance of inverters:

    1. There is no display, this situation is relatively common, generally in the normal case of the external three-phase power supply, it is the switching power supply of the inverter that is burned.

    2. The output three-phase is unbalanced, if the balance rate does not exceed plus or minus 15%, it is definitely not usable, the voltage can be measured through the voltage level of the multimeter, and the current can be measured by the clamp meter.

    3. The speed is unstable, try to avoid the inverter working in the low-frequency state, generally need to set the inverter above 8Hz, if the high frequency is still unstable, you can adjust the Vf ratio to a lesser point.

    4. If the motor sound is too loud and the motor temperature is high, the carrier frequency can be appropriately increased, and the output waveform of the inverter will be ideal. If the inverter interferes with other equipment during operation, the carrier frequency can be appropriately reduced.

  7. Anonymous users2024-02-04

    The purpose of the inverter daily maintenance training is to let the participants master the basic principles, operation methods and common fault handling skills of the inverter, so as to ensure the normal operation and maintenance of the inverter. Specific purposes include:

    Improve the skill level of operators: Training can help operators understand the working principle of the inverter, master the correct operation method, and improve the accuracy and efficiency of the operation.

    Prevent failures and extend the life of equipment: Through training, personnel can learn the daily maintenance methods of the inverter, including regular inspection, cleaning and lubrication, etc., to reduce the occurrence of failures and extend the service life of the equipment.

    Improve troubleshooting ability: Training can help personnel learn common inverter fault phenomena and treatment methods, improve troubleshooting ability, quickly solve equipment failures, and reduce downtime.

    Improve safety: Training can educate personnel on correct operating procedures and safety practices, reduce the occurrence of operating errors and accidents, and improve work safety.

    In short, the purpose of the inverter routine maintenance training is to improve the skill level of the operator, prevent failures, extend the life of the equipment, improve the troubleshooting ability and work safety.

  8. Anonymous users2024-02-03

    Ensure that operators can carry out the maintenance work of the inverter correctly and safely, so as to ensure the normal operation of the equipment and prolong the service life of the equipment.

    Inverter is a kind of equipment used to control the speed of crude motors, which is widely used in industrial production. Routine maintenance is critical to the reliability and performance of your drives. The purpose of the training is to enable the operator to understand the basic principle, working process and common faults of the inverter, and learn the correct maintenance method.

    Through the daily maintenance training of the inverter, the operator can improve the understanding and mastery of the inverter, effectively prevent and solve common faults, ensure the normal operation of the equipment, and improve production efficiency and safety.

  9. Anonymous users2024-02-02

    1. Offline business methods. Check the local textile mills, metallurgical industry factories and other units that use more inverters, contact the person in charge of equipment and procurement, and then visit and contact more daily. This is a traditional face-to-face approach.

    2. Online business methods. Choose a fee-based publicity method to advertise in the automation industry**, major search engines, and B2B alliances; Choose free publicity methods, post more contributing posts on industry forums, publish free B2B information, blogs and Weibo and other platforms to add relevant information. It's a way to attract the right people.

    3. Combination of online and offline. Compare the user information obtained online, screen key customers, and hide which line of daily maintenance is on the side. I myself have talked about the online promotion of the carrier code ** course in Alibaba, you can find it for reference.

Related questions
21 answers2024-05-13

Henan's contact me, Henan Delta ** business - Zhengzhou Xinkai Electronic Technology ****!

6 answers2024-05-13

As of July 2021, it is generally around 200 for 1 horse, 250 for 2 horses, and so on. >>>More

11 answers2024-05-13

The commissioning of the inverter is mainly divided into two aspects: the mechanical part and the electrical part, and the following are the general debugging steps: >>>More

11 answers2024-05-13

Generally speaking, the deceleration distance is not enough, and basically there will be no phenomenon of stopping the elevator, and the elevator is generally a little higher or lower than the floor. >>>More

18 answers2024-05-13

Inverter frequency source setting problem: When some inverters are set to terminal control mode, the frequency source automatically defaults to the external frequency source. >>>More