Fourth, the key function 1, the number of period buttons: click the number of period buttons to switch the display of the current running cycle or number of segments, long press the button for 2s to enter the cycle setting state, and then press and hold for two seconds to exit. 2. Set the query key:
Click to enter the query status, you can query the number of sections currently running, set time, set temperature and set humidity, and then click the key to exit. Press and hold the key for 2s to enter the number of segments selection state, after selecting the number of segments, then click and press the button to enter the parameter setting state of each segment, in the setting state, then press and hold the setting query button for 2s to exit the parameter setting state of each segment (when the period is set to 0 and the first period is 0, the first segment of the program will be run forever); 3. Reduce button: When setting parameters, click the key to reduce the setting value by one, and press and hold the key to reduce the setting value continuously; 4. Add key, when setting parameters, click the key to increase the setting value by one, and press and hold the key to increase the setting value continuously; 5. Back (back) key:
When the parameters of each segment are set, click the key to return to the previous parameter (only the parameters of the same segment can be switched). When there is an alarm buzzer beeping, press the key to silence it. In the run-stop state, press and hold the button for 4s to make the controller run again from the first stage.
6. Temperature parameter (temperature) button: press and hold the button for 2s to enter the internal parameter state, click the button to set the internal parameters, and then press and hold for 2s to exit. 7. Illumination key:
Click the button to turn on the inside of the box. 8. Power button: Click the button to turn the controller on or off.
In each set state, if no button is pressed within 30 seconds, the program will automatically exit to normal operation. 5. Parameter description 1, each section parameter setting: long press the setting query key for 2s to enter the number of segments selection state, the cycle window displays "ch" to select the required number of segments, press the key to enter the parameter selection state of each segment, and the range of parameters is as follows:
Level 0 6. 2. Internal parameter setting: press and hold the temperature button for 4s to enter the internal parameter state, and enter the password lc=3.
In the state of internal parameters, press and hold for 4s to exit, and the parameters ** are indicated as follows: Parameter name Parameter function description Range(factory parameters) AL Overtemperature alarm When PV SP+AL, there is a refrigeration output. (CT Compressor Start Delay Compressor Delay Protection Time, Two Start Times = CT Minutes 0 10 (3) min pb Zero Adjustment pb = Mercury Thermometer Reading Value - Current Temperature Measurement Value PK Full Adjustment When the actual temperature deviates, the parameter value can be adjusted to correct. pk=1000* (mercury thermometer reading - current temperature measurement) Current temperature measurement -199 999(0) up Heating and refrigeration differential When the temperature rises, this parameter can control the compressor to open in advance, that is, when PV=SP+UP, and the delay time is greater than CT, there is a refrigeration output, and the output light is always on.
It only works when the ALM light is flashing. DN Cooling and Refrigeration Difference When cooling, this parameter can control the compressor to turn off the refrigeration output in advance, that is, when PV SP+DN. It only works when the ALM light is flashing.
-
It is recommended that you go to the Nuoding Information Network for consultation.
-
The microcomputer of the light incubator is fully automatic and simple, and the touch switch is easy to operate; Programmable multi-stage control mode, temperature, humidity, illuminance and time change room can be set separately during day and night. Air duct ventilation, soft wind speed and uniform temperature in the studio; Hollow reflective tempered film glass, good thermal insulation, beautiful and generous. Fully enclosed opaque lampshade, optional worker check room power supply, disinfection device, etc.
Guangdong Huankai drying oven is still good, the drying oven is safe, easy to operate, and the after-sales service is also good.
Turn on the power, press the setting button to automatically adjust the temperature to your required temperature, up and down about 2 degrees, other values do not need to be changed, just wait for it to automatically generate temperature. There is a built-in thermometer to see how much the temperature value of the display screen is different from the value on the thermometer, and it can be used if it is in a normal state within the setting range. If it is not used for a long time, it should be turned on for half a day every month to ensure the normal operation of the machine and maintain it.
Instructions, precautions and maintenance of biochemical incubator. >>>More
From the description, how to correctly use the constant temperature and humidity incubator and maintenance, the suggestions are as follows; >>>More