What you said should be that the pipeline through the workshop is frozen, which is caused by water in the pipeline, you should add a dryer behind the air compressor, and the compressed air will enter the workshop after drying.
-
Is the air compressor line or the refrigeration dryer line frozen.
-
Causes of icing at the compressor outlet:
1. The amount of liquid refrigerant in the throttle valve is normal, but the evaporator cannot absorb heat normally;
2. The evaporator absorbs heat normally, but the amount of refrigerant in the throttle valve is too much, that is, the refrigerant flow is too much, which we usually understand as too much refrigerant.
The reason for the freezing of the compressor outgas: the compressor return gas freezes due to the lack of fluorine.
Solution: As long as the hot gas bypass valve is adjusted, the adjustment process should not be too fast, generally pause after about half a turn, and let the system run for a period of time to see the frost situation and then decide whether to continue to adjust. Wait until the operation is stable and the frosting of the compressor disappears before tightening the end cap.
-
Is your air compressor an industrial gas in the station building? It is recommended to install air after-treatment equipment behind the air compressor, if the picture is cheap, install a refrigeration dryer, if you require a high point to install a suction dryer, I am a professional suction dryer.
-
When the temperature is low, it is necessary to drain the water in the gas tank and pipes at the end of the day, which may freeze the valves and pipes.
-
In the winter, you don't care what he does, and he won't freeze and crack.
-
Hello, the air compressor outlet pipe pipeline is frozen, you first have to stop the use of the air compressor, when the surface is cleared, then measure the pressure difference between the air compressor high-pressure pipe and the recall pressure pipe, and then increase the condensate appropriately, you can solve this problem, thank you, I hope it can help you.
-
If there is ice in the air compressor outlet pipe, it means that there is some exhaust blockage in the air compressor, as long as it is dredged, he will not have this phenomenon.
-
Under this kind of payment you need to install a filter.
Filter the water and impurities.
Keep the air dry and clean.
At the same time, the temperature is not too low.
-
Look at the oil level gauge, you have to run it to see accurately, and if you have more, you can put it out.
See if the return pipe is blocked.
If not, it should be the oil running out. You have to replace the oil, and generally speaking, how can the oil be perforated.
-
Air compressor outlet management icing? If the primary management of the air compressor is icing, is the outside temperature or the inside is lowered, please ask professional personnel to see, you can see or ask the after-sales customer service.
-
Then this situation is likely to be due to the failure of the compressor in the temperature, which is likely to be the cause of poor drainage.
-
The air compressor goes out to play with the icing inside, this should be necessary to turn up the temperature a little, and then ask him to pour out the water, or you take a wet rag, and then wipe it off, this should be okay.
-
The air pump freezes ice in winter, and users can put the air pump indoors to prevent freezing ice. Air pumps are mainly divided into electric air pumps, manual air pumps, and foot-operated air pumps. Electric air pump. An air pump powered by electricity continuously compresses air to generate air pressure.
It is mainly used for gas pumping, sewage treatment, electroplating and blasting, biogas digester aeration, tunnel ventilation, etc. The high-pressure air pump is a vortex air pump for both blowing and suction, and the special blade design of the high-pressure air pump has the characteristics of high pressure, large air volume, low noise and high temperature resistance. The blower has strong insulation, easy installation and high stability.
The passing gas is oil-free and dry.
The high pressure and high suction power are generated by the unique design of the impeller. When the impeller rotates, due to centrifugal action, the air in the two blades is rapidly moving to the outer edge, transferring energy, and the wind pressure is rapidly superimposed, forming a high pressure or high force, and its speed is increased.
When the air is redirected to the impeller by the air duct, it is accelerated again. As multiple blades transfer energy, the wind pressure is rapidly superimposed, resulting in high pressure or high suction.
-
You can close the lid on the box for the pressure switch.
Use a plastic bag with good sealing performance to cover the whole box, a little thicker, wrap a few more layers of cotton waste cloth on the outside and then put a plastic bag on the outermost layer, wrap the entire pressure controller at the root and tie it with a thread, the copper pipe of the thimble should also be wrapped with a cloth, as long as the icing level is not lower than 0 degrees, it will not freeze, and then take it off when the season warms.
-
This is the water inside frozen, heat, let the water inside thaw on it.
-
1. Push the painted air pump to a warm room, or remove the exhaust pipe and take it to the room to melt the ice inside, so that the time is slightly longer.
2. You can remove the exhaust pipe and put it on the heating or roast it with a fire, or you can use a baking lamp, so that the ice melts faster.
3. You can also use a plate type electric heater to put it under the car, and wrap it around the car with a sheet.
4. Pour hot water over the exhaust pipe.
5. After not using the paint air pump, drain the water in the exhaust pipe to prevent freezing.
-
The best way is to install an oil-water and gas-water separator in the air pump. Don't prepare or invest too much. The gas reservoir of the Isuzu dump truck with a load of 12 tons itself has the function of oil-water separation (you look for it, other models can also use it), connect this gas reservoir to the outlet pipe of the air pump, and the air reservoir should be as close to the air pump as possible, so that the temperature of the air reservoir will not be too low, it will not freeze, and it can be manually discharged, and there are also automatic water releases.
-
Make a self-made heating machine, is connected to the air pump and the gun of the transfer, it can be connected to electric heating, can be assembled by yourself, the gas from the air pump will be heated to remove water and then enter the gas pipe connected to the spray gun, the equipment should not be difficult to buy, you buy the paint room to sell the equipment should be able to buy, I hope my answer will be helpful to you.
-
If the pipeline is outdoors, it is recommended to frequently drain the water from the gas pump storage tank Add a few oil-water separators in the gas pipe, and I personally feel that adding heating facilities is not very useful. Spray paint has high requirements for compressed air quality, and water and oil are discharged as soon as possible.
-
It would be nice to add a small compressed air heater, ** is sold.
-
It's time to replace the filter element of the oil-water separator Most types of oil-water separators are frozen inside, and it should be solved by scalding it with boiling water in a pot.
-
Directly at the position of the trachea, wrap a layer of insulation cotton, which can well ensure that the trachea is not frozen, and the temperature remains balanced.
Of course, if the temperature is too high, or if the tube is combined with hot and cold, there will definitely be a layer of frost on the outside.
-
First of all, you can install a timer, automatic exhaust valve at the position of the exhaust pipe of the air compressor, set the time, about five minutes, and then let it automatically discharge the liquid and gas inside, which can prevent the water in the pipe from freezing and freezing.
-
Put the air compressor indoors or build a temporary tent in winter as much as possible, which can not only prevent the temperature from getting too low, but also improve the air quality of the air inlet of the air compressor and keep the temperature of the air compressor room above freezing. Pay attention to keep the environment clean and tidy, especially pay attention to the equipment around the equipment and the ground of the station building without water accumulation, in order to prevent ice and slip.
-
This must also keep its trachea warm. In other words, in our case, it is generally wrapped in a warm film. Relatively speaking, it is generally not passive, this is determined by the weather.
-
When using an air compressor at low temperatures, you should deflate the air compressor every once in a while, especially before shutting down, and drain the water in the tube to effectively prevent freezing.
-
After the shutdown in winter, we must pay attention to the evacuation of all gases, sewage and water, and the water, gas and oil in various pipelines and gas bags, because the temperature is relatively high when the unit is working in winter, and a large amount of condensate will be generated after the air is cooled due to the low outside temperature.
-
The reason for the unsmooth return of the screw compressor is mainly due to the gas mixture of lubricating oil and refrigerant during the operation of the machine. In the operation of the refrigeration system, the refrigerant and the refrigeration lubricating oil are miscible with each other, resulting in the operation of the lubricating oil and the refrigerant being discharged into the condenser in the form of aerosol and micro-droplet gaseous state.
-
The air compressed from the air compressor will contain some moisture, and when the condensate is discharged through the automatic drain valve, it will be affected by the low temperature outside and freeze in the pipeline or other parts.
-
Give me the air compressor to ensure that the air compressor tube does not freeze. First of all, find some cotton cloth and use cotton cloth to wrap the air compressor's air pipe, so that it will not move.
-
If you want to make the air compressor air pipe not easy to move at low temperatures. To reduce the humidity of the air. Do not produce moisture after compressing the air. In this way, the trachea is not easy to move.
-
This is to use the air compressor while heating, that is, before using the air compressor, make sure that the surrounding temperature is not too low, remember to keep the temperature constant!
-
Before starting the machine, be sure to jog the operation correctly 2-3 times, let the air compressor lubricating oil preheat it, and do not start the air compressor directly!
-
If the temperature is too low, you should change the air compressor oil at a thin point to keep it warm before starting, and manually turn the car so that the oil can be coiled.
-
In winter, put the compressor in the house, and then have a stove in the house, etc., so that the heating facilities will not freeze the pipes.
-
That is to do a good job of thermal insulation measures.
-
Hello, your body is not ambiguous and I sleep at night and my body is not hot. It's not warm to cover two quilts. It's been almost a year or two, and I think it may be caused by weak constitution and lack of qi and blood.
Strengthen nutrition, rest and exercise. It can also be combined with acupuncture and moxibustion to replenish the kidneys and help yang, greatly replenish vitality, replenish qi and generate blood, and the effect is good.
-
Use a hair dryer to heat the heating pipes.
-
What should I do if my trachea is frozen?
Reasons: 1. The V-belt of the air compressor is too loose; >>>More
This is normal, it is the overpressure protection of the air pressure, if there is no air leakage, your air pump has been pressurized, the gas tank has burst, what to do, safety valve. >>>More
According to your statement, your unit uses an oil-free screw machine, and the total gas consumption is relatively large, and the system requirements are relatively high. In fact, there are many aspects to start with when it comes to energy saving. >>>More
The top ten air compressor brands in the country are: Atlas Copco Group, Ingersoll Rand (China) Investment, Shenzhen Sullair Asia Industrial, Fusheng Industrial, Kaishan, Compuai, Jaguar Jaguar, Bolaite, Gesu, Hitachi. >>>More
The gas tank is 10 to 20 percent of your gas consumption. >>>More