Personally, it is also recommended that everyone install a floor drain.
Target. Because the floor drain in the shower area is actually specially used for showers, the drainage range it controls is not very large. Then there is the toilet, in addition to the shower room, these three are necessary; There are also bathrooms, washing machines, more upscale toilets, and bathtubs.
We refer to the shower area as the "wet zone", the sink as the "dry zone", and the toilet as the "semi-dry zone". In our case, we only consider the distance between the shower area and the sink.
The area where people often move such as washbasins is far away to avoid water on the ground, or when the floor drains and drains, it will affect the use of sanitary ware or the passage of toilets. The number of floor drains in the bathroom should correspond to the necessary functions, and we count the number of sewer pipes, design the layout of the bathroom, and lay out various bathroom equipment, etc., all of which are related to the number of sewer outlets and the number of floor drains. It's an important place in our lives, and sometimes it's an extraordinarily clean place in our homes.
Therefore, we are not stingy in our investment in the bathroom, and we are very willing to put effort to lay out the floor tiles.
Noticeable unevenness. So I personally recommend installing another floor drain next to the toilet.
So the bathroom floor drainage system is mainly composed of floor drains, today I will share with you, how many floor drains are the most suitable for the bathroom? I hope the following analysis will be helpful to you in solving the number of floor drains in the bathroom. If there is no separation of wet and dry, then one in the shower area will do.
Because the bathrooms have a slope of the floor. So there's no need to put too many floor drains. I believe that many people are not clear about this point and cannot give an accurate answer.
So, today we will talk about how many "floor drains" are most suitable for the bathroom.
The bathroom generally has two floor drains, which is completely fine. It's just to get into the water faster. But it should also be installed according to the size of the bathroom, if the area is relatively small, it is completely okay to install one!
In the later stage, the waterproofing of floor drain must be dealt with well, which is the main leakage point. Generally, it is not recommended to increase floor drains, the drainage pipes are located under the floor slab, the construction is inconvenient, and the construction needs to be carried out in the downstairs room, and the hidden danger of water leakage is also relatively large.
-
Renovation of the bathroom, there is no need to install more floor drains, what problems can the floor drain solve, two floor drains are enough, a shower floor drain, a washing machine floor drain can be.
-
It will indeed be a little better, so that it can ensure that the bathroom is not so easy to leak and accumulate water, and it will also make the smell of the bathroom not so serious
-
Yes, I think there should be at least three floor drains. A floor drain is the water that flows out after bathing, a floor drain is the water that flows out of the washbasin, and a floor drain is the water that flows out of the washing machine.
-
It's not good to install a few more, mainly because the bathroom will often drain down, and if you install a few more, it may cause changes in the soil, which may cause some damage.
-
It is not better to have a few more floor drains. When renovating the bathroom, installing a few more floor drains may cause the smell in the sewer to come up and affect the hygiene of the bathroom.
-
No, and it is enough to install one, so that you can also achieve the effect of exhaust, and at the same time, there will not be too much odor from the floor drain.
-
Yes. This allows the washing machine and sink to be clearly divided into drains without causing clogging.
-
The bathroom has been renovated, can the floor drain be replaced? What to do?
Before replacing the floor drain, it is necessary to carefully check the panel and size of the old floor currently in use, that is, the specification model. The 10 * 10 cm square, which is usually used the most at home, predominates, but it cannot be ruled out that some residences are equipped with models with a round 12 cm. As for the size of the sewer pipe, the diameter of the sewer pipe in the general residential house is 50 pipes, that is, the diameter is 50 mm, and the tributaries of the general manufacturer meet this requirement, so there is no need to consider purchasing.
The size of the new panel should be the same as that of the old floor. Just slowly remove the old leaking panels and tile joints with a screwdriver or other tool, and then remove the old leaks.
Before setting up Emergency 4 to prevent leakage, it is necessary to take out an anti-odor heart. Because, if you don't take it out and install it directly, you can put cement, sand and other sundries into the core, and the use effect will be greatly reduced. Very assured, with the panel and tile, pay attention to the height should not be higher than the tile, and coat the surrounding glass glue or white cement to dry.
Finally, set up an anti-odor core with a very deep four-leakage proof, and put it on the grate for normal use. Generally, if you use it for about a month, you can take out the deodorant heart, put it in water to wash, and continue to use it.
What are the precautions about floor leaks? Before installing, the floor drain must be removed. This prevents debris from falling into the inside of the underground core and causing damageThe purpose of installing ground leaks is to drain water, so the location of installing ground leaks should be lower than the ground to facilitate drainage.
Before the installation of floor leakage, if the drain pipe is too close to the ground, the drain pipe should be reduced by an appropriate amount so that the installed floor leakage is lower than the ground, so as not to affect the use. In order to prevent damage to the overall decoration effect, the installation position of floor leakage can not exceed the ground, therefore, if the drainage pipe is too far from the ground, the purpose of improving the drainage pipe can be achieved by applying cement mortar charging. The floor leaks and is installed to ensure an aesthetically pleasing decorative effect.
Floor leakage installation Considering the convenience of maintenance in the future, floor leakage cannot be used directly when filling cement mortar. Instead, roll kraft paper or other hard materials into a cylinder consistent with the sewage pipe, dock with the sewage pipe, raise the ground, and then fill it with cement mortar. The tributaries are docked with the sewage pipeline, the ground is raised high, and the stirred cement mortar fills the surrounding gaps, so that the floor drain adjusts the height of the panel to a suitable position, and when the cement mortar hardens, the leakage is added to the pipe formed to make it tight with the pipe wall.
When the land used by the washing machine leaks, you can purchase a special washing machine floor leak or joint. Of course, it is also possible to use ordinary floor leaks directly. The drain casing only needs to be inserted into the fixing pin on the floor leak, but it is not as practical and convenient as before.
-
Yes, you can change it. Remove the tiles on the side of the floor drain, install the floor drain to be installed, and then make the tiles right.
-
It is possible to replace the floor drain, and the floor drain needs to be replaced before the bathroom is decorated, and then the bathroom is decorated, so that it will not affect the environment of the bathroom and the water of the bathroom.
-
The bathroom has been renovated, and the floor drain can be replaced, but the panel and size of the floor should be carefully checked before replacing the floor drain, and the waterproof must be done well after the replacement to avoid water leakage.
-
How many floor drains do you need in the bathroom? Is more the merrier? Or is less the merrier?
It is not necessary to have too much, but too little is not good, generally it is necessary to match 2 odor-proof floor drains inside, and a floor drain is installed in the drainage of the overall shower room, which is conducive to the water can be discharged immediately after the shower. Another floor drain is installed in the wet area, usually between the toilet and the washbasin, because the relativity of the road surface next to the toilet is very low, and the installation of a floor drain here can prevent the occurrence of water storage.
It needs to be kept away from the entrance of the bathroom, because the anti-odor floor drain function is the drainage pipe deodorization and mothproof, if it is too close to the area where the bathroom enters the door, it will not be effective, and it will affect other areas of the home. It is necessary to ensure that the surrounding area of the anti-odor floor drain is relatively wide, so that it is more convenient to clean, and many customers feel that it is not good-looking, and want to use decorative design to hide it, as if it is placed in a narrow area on the back of the toilet.
Wet and dry partitions in the bathroom mean that the shower area should be separated from the sink. However, even if it is considered a sink in a wet area, there will be water on the floor. The second anti-odor floor drain in the bathroom is intended for wet drains.
The common two separate partitions in the bathroom, although the dry humidity is also separated, but the effect is not too good. If there is a large flow of water on the ground, it is still possible to flow out according to the road surface - then make a hole in the sunny corner of the ground (or simply do not need to drain him) and use it for drainage pipes.
However, if the effect of the wet and dry zones is more appropriate, such as the design scheme of moving the washbasin to the door of the toilet, it will be difficult to flow to the wet area after the wet area is covered with water. In this case, it is necessary to install an anti-odor floor drain next to the sink to drain the water stored on the wet floor.
No matter how large the total area of the restrooms, both areas are in close proximity. At this time, there is water storage on the ground in the wet area, which can be discharged according to the floor drain in the wet area. However, if it is a long toilet and there is a toilet between the wet area and the wet area, and there is still water on the floor of the wet area, it must pass through the toilet and then flow to the wet area to drain away.
If two anti-odor floor drains are installed, the slope of the bathroom floor needs to be separated - with the dry and wet separation partition as the boundary, the road surface on both sides leaks water to the ground within their respective ranges. In doing so, it also ensures that every odor-proof floor drain can be fully utilized; And make sure that it is not easy to cause water storage around the decoration partition that cannot be drained.
-
The more dettol in the bathroom, the better, generally the bathroom needs two floor drains is enough, which can effectively ensure the dredging of the toilet water source.
-
In general, three are needed, not more is better, and it should be determined according to the actual usage.
-
Floor drain has a very important position in the bathroom, can be drained at the same time, filter out the debris that can or can cause the sewer pipe to clog, usually a bathroom can be installed with a floor drain, but if there is a washing machine, it may be particularly troublesome. So, what are the ways to change one to two bathroom floor drains? How to determine the installation location of the floor drain in the bathroom?
Let's take a brief look at it together.
First, the bathroom floor drain one to two methods.
1. Determine the location of the new floor drain, it is best to be in the same straight line with the original floor drain, and then excavate a groove slightly larger than the water pipe, lower the pipe, install the floor drain, and finally restore the ground, the cost is large, and it is not recommended to use the decoration; 2. Install a round three-way floor drain at the position of the original floor drain, so that there can also be two floor drains, but the aesthetic performance is slightly worse.
2. How to determine the installation location of the bathroom floor drain.
1. It is best not to install it in the middle.
Generally speaking, the best drainage position should be in the middle, but in fact, there are many disadvantages of installing in the middle, first of all, the flow direction of sewage is not well concentrated, and may be biased to one side, so the floor drain can not show its due function. Secondly, if the floor drain is installed in the middle, if it is not cleaned often, it is very easy to produce bacteria, and even insects will grow, which not only affects the use, but also affects the appearance.
2. Install it in a hidden and wide position.
The floor drain should be installed on one side of the bathroom, requiring that it should not affect the drainage, and it is best to conceal it, so that it will not affect the beauty of the bathroom, and it can also fully display the function of filtering and draining the floor drain, but no matter what position the installation loves, it is necessary to pay attention to the daily hygiene, and when it is found that there are hairs or other debris that will block the floor drain, it should be removed in time.
-
The floor drain in the bathroom at home is old or broken and needs to be replaced. Can I change the floor drain after the bathroom is renovated? How to replace the floor drain so as not to damage the waterproof?
Here's how to replace it. Follow these steps to replace:
1.Before replacing the floor drain, you need to pay attention to the basic information such as the panel and size specifications of the old floor drain currently in use, and the most used in the bathroom at home is a 10*10cm square floor drain, and there are also 12cm round floor drains; As for the size of the toilet sewer pipe, the diameter of the sewer pipe of the general house is 50mm in diameter. Note that the size of the core floor panel to be replaced should be consistent with the size of the old floor drain;
2.The joints between the old floor drain panel and the tile are slowly separated with a screwdriver or other tools, and the cement around the floor drain is lifted out with a slotted screw, and then the floor drain is struck with a small hammer to separate it from the cement; Use a groove to clean the cement layer around the old floor drain pit, and pay attention to the temporary plugging of the drainage pipe to prevent debris from falling into the drainage pipe;
3.After cleaning, scrape cement putty around the pit wall; The reverse side of the new floor drain that needs to be replaced is also scraped with cement putty to make it firmly combined with the ground, and the excess cement dining area will be cleaned up of the ground garbage. Before installing a new floor drain, the anti-odor core needs to be taken out to prevent cement and sand and other creations from entering the core and affecting the use effect; The newly replaced floor drain panel should be in line with the tile, the height should not be higher than the tile, and the glass glue or white cement should be applied around it and dried; After installation, install the floor drain anti-odor core and put the grate; It is recommended that the deodorant core can be taken out and cleaned once a month or so, and the use effect is better.
Finally, it is worth mentioning that no matter how the bathroom decoration is, it is necessary for us to understand the common sense of bathroom decoration. I think that in order to effectively implement the precautions for bathroom decoration, we must have some toilet safety knowledge, so as to avoid accidents that should not occur. Rotten hall sales.
The key is to have a U-bend that can store water, so that it will not run out of flavor.
What factors should be considered when installing floor drains in the bathroom? The floor drain is an important interface connecting the toilet drainage pipe and the bathroom, and if it is not handled well, it will lead to problems such as odor and yellowing. It is not easy to replace the floor drain after installation, so before installing the floor drain, you should choose different floor drain styles in different areas of the bathroom according to the master's advice, and make a strategy in advance. >>>More
How many floor drains do you need to leave in a bathroom? >>>More
BathroomsFloor drainsIt can be changed. >>>More
When you choose a floor drain, you must pay attention to the performance, the most important anti-odor floor drain performance, new decoration as long as you know the diameter value of your sewer pipe, if it is replaced, you need to use the size and shape of the floor drain in your home now! >>>More