How to deal with the automatic water bile tank without water storage?

Updated on home 2024-06-28
7 answers
  1. Anonymous users2024-02-12

    The water tank is a public toilet.

    The main device, if there is a failure, it will bring great inconvenience to life, therefore, for some small faults of the toilet tank, you should deal with it yourself, among which the leakage of the toilet tank is the most common failure, then, what should I do if the automatic flushing tank of the public toilet does not store water? Let's first understand the principle of automatic toilet flushing tank.

    Toilets. The water tank should be installed with an automatic flushing device, it has a float valve inside, as the water level in the tank rises, the buoyancy generated by the float is getting bigger and bigger, when the water level rises to a predetermined value, the buoyancy generated by the float will be transmitted to the plug of the water discharge through a seesaw structure, as long as the drain button is pressed, the plug can be automatically pulled up. After the water is discharged, the plug automatically returns to its position under the action of the spring and enters the next round of water filling cycle.

    What to do if the toilet tank is leaking:

    1. Aging of internal parts of the water tank: If the internal parts of the water tank are aging, there is no other choice, you only need to replace the parts quickly.

    2. Water leakage at the connection between the toilet and the sewer pipe: If the connection between the toilet and the sewer pipe leaks, you need to reinstall the toilet and re-seal.

    3. Cracks in the toilet itself: If the toilet is cracked and causes water leakage, replace it with a new toilet.

    4. The problem of the water inlet group and the water outlet group of the toilet: you need to open the water tank and see that the water tank is overflowing, and the water flowing out of a water pipe indicates that the water inlet group is broken, and if there is a sound of water inflow, the water outlet group is broken.

    5. Water tank leakage: You can take off the drain machine core to clean up the scale, if it still doesn't work, you need to change the toilet.

    6. For the problem of water tank material, the solution is to separate the toilet tank, one by one to check whether the parts in the toilet tank are intact, if some parts are broken, they can be repaired, and those that cannot be repaired will be replaced.

  2. Anonymous users2024-02-11

    This kind of more professional knowledge still needs to be handled by professional people.

  3. Anonymous users2024-02-10

    The reason for the non-automatic drain is that when the water level of the incoming water is lower than the curved part of the upper end of the siphon, this is because there is air in the pipe and the siphon phenomenon will not occur, so the water tank is not automatic drainage.

  4. Anonymous users2024-02-09

    Hello, I'm glad you about "How to deal with the water tank without water storage in the self-contained shed moving water bile tank?" ".

    When there is no water storage in the automatic water tank tank, it may be caused by problems such as blockage and excessive water flow in the tank. At this time, it should be dealt with as soon as possible to avoid causing greater losses and impacts.

    First of all, the whole tank should be checked whether there is a blockage phenomenon, if the blockage and plugging, it should be disposed of immediately to avoid the blockage expanding and causing greater damage. Secondly, the water flow should be checked if it is too large, and if so, the flow should be adjusted immediately to reduce the flow rate to avoid damage to the water tank.

    In addition, the tank should be checked for leakage, and if so, the hole in the tank should be sealed as much as possible to ensure that the tank is intact.

    In short, when the automatic water tank does not store water, you should check whether the water tank is blocked, whether the water flow is too large and whether the water tank is leaking, and take timely treatment measures, I hope this can help you!

  5. Anonymous users2024-02-08

    Dear, hello, I'm glad to answer your question, the new automatic water tank does not drain when the water level of the injected water is lower than the curved part of the upper end of the siphon because there is air in the pipe will not siphon phenomenon, when the water level is higher than the curved part above the water pipe, the water pipe is filled with water, the siphon phenomenon occurs, and the water in the tank is automatically flushed out to flush the sewer until the water level drops below the elbow inlet. Then the second water storage process begins. After the water is full, the siphon phenomenon occurs, as long as the inlet water is adjusted reasonably, the sink can be guaranteed to flush regularly and quantitatively.

    1.The drain pipe is not obstructed or the drain pump is blocked. 2.

    Broken computer board. 3.The drain pump is in poor contact with the computer board or the drain pump is bad.

    4.Check if the drain is bent or too high. If not, open the filter door and check if the filter is blocked.

    5.If the filter is not clogged, check that the drain pipe is draining. 6.

    If the drain pipe cannot drain water, check whether the drain pump plug wire is loose and whether the drain pump is burned out.

  6. Anonymous users2024-02-07

    Summary. What are the reasons why the automatic flush tank does not flush 1. Why does the automatic flush tank not flush when the flush valve is damaged? The induction automatic flush tank relies on the induction flush valve to control the flushing, when someone enters the flush valve sensing range, the sensor of the flush valve will detect the change of the infrared spectrum of the human body, the switch will automatically turn on the load, the person does not leave the sensing range, the switch will continue to be turned on, once the person leaves, it will automatically flush.

    If the flush valve chip is damaged, it is not possible to control the flush automatically.

    What should I do if the water in the automatic water tank of the public toilet cannot be turned off, and what if the water is not flushed?

    What are the reasons why the automatic flush tank does not flush 1. Why does the automatic flush tank not flush the water when the flush valve is damaged? Induction automatic flush tank is relying on the induction flush valve to control the flushing, when someone enters the flush valve induction fan Zeshiwei, the sensor of the flush valve will detect the change of the infrared spectrum of the human body, the switch will automatically turn on the load, the person does not leave the induction range, the switch will continue to be turned on, once the person leaves, it will automatically flush. If the flush valve chip is damaged, it is not possible to control the flush automatically.

    2. The water inlet pipe control valve is damaged, and the water inlet pipe control valve of the automatic flushing tank will be naturally damaged after being used for a period of time, resulting in the water tank has been entering or not entering the water, and the water will leak out of the overflow pipe after exceeding, and will not be discharged from the drainage pipe. 3. There is a float valve in the float valve siphon automatic flush tank, and the siphon phenomenon will not occur when the water level of the injected water is lower than the curved part of the upper end of the siphon. When the water level is higher than the float valve, the siphon phenomenon occurs, and the water from the water tank is automatically flushed out to flush the sewer, and the straight stove is wide enough to drop the water level below the elbow inlet.

    After the float valve is damaged, the siphon phenomenon cannot be controlled. 4. Pipeline blockage.

    How to deal with the automatic flush tank in the toilet that does not flush and how to repair the automatic flush tank without flushing? If the flush valve is damaged, simply replace the sensor flush valve. 2. If the control valve of the inlet pipe is damaged, the debris in the control valve should be cleaned up first, and then the control valve should be replaced.

    3. If the float valve is damaged, you can replace the float valve directly, or you can use watering to glue the damaged part of the float valve, and then put it in the water tank. 4. If the pipeline is blocked and the automatic flushing tank is not flushed, the pipeline needs to be thoroughly cleaned, and if necessary, the pipeline can also be replaced.

  7. Anonymous users2024-02-06

    Hello Tongyan, I am glad to answer for you that the public toilet automatic flushing tank falls into the water and the gall does not come out of the water The public toilet automatic flushing tank is full and does not flush because the float valve is broken or the pipe is blocked. In public toilets, it is common to see a device that automatically drains water at regular intervals, and it is a sanitary device made according to the phenomenon of siphoning. The phenomenon of siphoning is common in everyday life.

    Take a long rubber tube filled with water, pinch both ends with your hands, and insert one end of the rubber tube into the bucket on the table, so that the other end of the rubber tube hangs on the outside of the bucket, and the rubber tube hanging on the outside is longer. Loosen your hands on the ends of the tube, and the water in the bucket will flow out until the water level in the bucket drops below the mouth of the tube. This is because the rubber tube is filled with water, and the atmospheric pressure presses the water into the rubber tube, and because the outlet of the rubber tube is lower than the water level in the bucket, there is a pressure difference, and the water flows out of the tube.

    This is the siphon phenomenon. The automatic flushing device of a public toilet is shown in the picture, which turns on the faucet and fills the water tank that hangs high above the roof of the toilet. When the water level of the injected water is lower than the curved part of the upper end of the siphon, there will be no siphoning phenomenon because there is air in the pipe.