Article 8 When the boiler product leaves the factory, it must be accompanied by safety-related technical information, and its content shall include:
1.Boiler drawings (including general drawings, installation drawings and drawings of main pressurized parts);
2.Strength calculation book or calculation result summary table of the compression element;
3.Calculation of safety valve discharge or summary of calculation results;
4.Boiler quality certificate (including factory certificate, metal material certificate, welding quality certificate and hydrostatic test certificate);
5.boiler installation instructions and instruction manuals;
6.Information on major design changes to pressurized components.
For boilers with rated steam pressure greater than or equal to , at least the following technical information should be provided:
1.Boiler thermal calculation book or summary table of thermal calculation results;
2.Superheater wall temperature calculation book or calculation result summary table;
3.Flue gas resistance calculation book or calculation result summary table;
4.Diagram of a thermal expansion system.
For boilers with rated steam pressure greater than or equal to them, the following technical information should also be provided:
1.Reheater wall temperature calculation book or calculation result summary table;
2.Boiler water circulation (including steam-water resistance) calculation book or calculation result summary table;
3.Diagram of the soda system; 4.The setting value of each protection device.
-
Steam Boiler Safety Supervision Regulations
Article 8 When the boiler product leaves the factory, it must be accompanied by safety-related technical information, and its content shall include:
1.Boiler drawings (including general drawings, installation drawings and drawings of main pressurized parts);
2.Strength calculation book or calculation result summary table of the compression element;
3.Calculation of safety valve discharge or summary of calculation results;
4.Boiler quality certificate (including factory certificate, metal material certificate, welding quality certificate and hydrostatic test certificate);
5.boiler installation instructions and instruction manuals;
6.Information on major design changes to pressurized components.
For boilers with rated steam pressure greater than or equal to , at least the following technical information should be provided:
1.Boiler thermal calculation book or summary table of thermal calculation results;
2.Superheater wall temperature calculation book or calculation result summary table;
3.Flue gas resistance calculation book or calculation result summary table;
4.Diagram of a thermal expansion system.
For boilers with rated steam pressure greater than or equal to them, the following technical information should also be provided:
1.Reheater wall temperature calculation book or calculation result summary table;
2.Boiler water circulation (including steam-water resistance) calculation book or calculation result summary table;
3.Diagram of the soda system; 4.The setting value of each protection device.
If it is not a steam boiler, there are also corresponding supervision regulations that can be consulted.
-
Product quality certificates, energy efficiency test reports, delivery lists, instruction manuals, boiler inspection audit and stamped drawings, etc. are required, and then there are classified information, heat conduction oil furnace and steam boiler information is different, and there is a quality certificate when I bought a cylinder or a high and low slot.
-
Take a closer look at the scrapping conditions. Do not include other organization names in the content. The bidding format is according to the bidding documents, and the missing content can be added, and the original can not be reduced (written without can not be reduced). The stamped part is clear. How to seal the label, see clearly. There are differences.
-
That's some expertise. Let's start with the basics. You can start with some basic knowledge of boilers and find some relevant national standards to learn first. Then look at something else. Take it easy.
-
What boiler? Modular? Atmospheric or vacuum?
-
A hundred stoves cost about 1,000 yuan, and the living room can be fitted with two 18 pieces in the bedroom, and 20 pieces in the bedroom is about 90 pieces. ...A piece is about 12 yuan....Plus 150 pipe fittings, 24 pipes, about 17 circulating pumps, and 200 ......... thermostatLabor costs of ...... 300,400That's all.
-
If you don't just look at the area, you can also look at the height and length of the room, and how many turns there are.
-
Dongbao heating stove, heating can also be installed, as well as underfloor heating. It's all warm and it's not expensive.
You can add a layer of insulation board to the house, the insulation effect is very good in winter, and the cost is not high.
-
Hunan rural housing Xie 180 square meters of four bedrooms and two living rooms, want to install coal-fired boilers and radiators, what is the cost? How to choose the main equipment? Is there a suitable company to recommend? Thank you!
-
Most of the small earth heating stoves of 120 square meters can be brought up, but don't buy too cheap ones to use.
-
The Döle stove is a good choice.
-
120 stoves, 100 ordinary radiators Good radiators can reduce ......The stove is bigger and the effect is better, after all, the house is high.
-
When applying for review, the certificate holder shall submit the following materials:
1) Application Form for Review of Special Equipment Operators (see Annex B, 1 copy);
2) "Operator Certificate" (original);
3) Safety education and training certificate issued by the employer or professional training institution during the certificate holding period (the content and class hours meet the safety technical specifications, 1 copy);
4) The physical examination report of the current year issued by the hospital (1 copy if the assessment syllabus has special requirements for physical condition);
5) A certificate issued by the employer that the operation time of the project held by the employer has not exceeded one year during the period of holding the certificate (if the relevant safety technical specifications provide otherwise, such provisions shall prevail);
6) Certificate of no bad records such as illegal operations issued by the employer during the period of holding the certificate (1 copy);
If all of the following requirements are met, the review shall be approved:
1) The materials submitted in the application for review are complete and true;
2) Under the age of 60 (including 60 years old);
3) The operation time of the licensed project is not more than 1 year during the period of holding the certificate (if there are other provisions in the relevant safety technical specifications, follow those provisions);
4) There is no bad record of illegal operations and other bad records, and no accidents have been caused;
5) Comply with the requirements of the relevant safety technical specifications;
6) Participate in the examination in accordance with the requirements of the relevant safety technical specifications and pass the examination.
-
What materials do I need to prepare for the qualification review?
-
You can revisit the boiler operation certificate online.
-
Lanzhou 2021 stoker certificate annual inspection.
-
The boiler can be heated with an area of 3,000 square meters.
Algorithm: boiler calorific value of 200,000 kcal per hour is equivalent to calorific value of 200,000 kcal per second 3600 seconds joules = 233 kJ seconds, equivalent to power 233 kilowatts; In the north, the thermal index is taken as 60 watts of square meters, then 233,000 watts of 60 = 3,883 square meters. Reserve some amount to round up to 3,000 square meters.
-
As far as the housing structure in the north is concerned, generally 1 ton can heat 6,000 square meters, 1 ton can be 600,000 kcal, and large calories can be flattened.
-
4 tons of hot water pot to furnace heating area of 32,000-40,000 square meters.
source hot water boiler.
Performance characteristics:1The thermal efficiency of hot water boiler is more than 77%, which is higher than the standard of "General Technical Conditions for Industrial Boilers".
2.The boiler is quickly installed and shipped out of the factory, and after it is used at the site, it can be operated by installing valves and instruments, drums, induced draft fans, flue gas pipes, dust collectors and water circuits, etc., and has the characteristics of fast starting and ignition.
3.The boiler is easy to install and move, which can save a lot of infrastructure investment.
4.Class II bituminous coal with low calorific value of 17750J kg, volatile matter and ash content.
Scope of application: Atmospheric hot water boiler series is the ideal first choice for heating, bathing, air conditioning and domestic hot water in various industries such as enterprises, institutions, hotels, schools, etc.
-
A 1-ton hot water boiler can supply 8,000-10,000 square meters, and a 4-ton hot water boiler can supply 32,000-40,000 square meters.
-
Different regions have different heating surface solutions, and one square meter needs 80-150 kcal.
Causes of boiler coking: 1. Coking is related to ash melting point. If the installation angle of the burner is skewed, the burner itself is defective, the burner is too large, and the pulverized coal gas flow is deflected and rubbed against the wall, which will often lead to serious coking of the boiler. >>>More
1.Choose a reasonable amount of oxygen for operation.
2.Select a reasonable furnace outlet temperature to optimize the combustion adjustment test of the boiler, and discharge smoke from the furnace. >>>More
The pressure-bearing parts of the boiler include all the parts of the "pot", that is, all the steam and water systems. >>>More
Here is the 30-man squad for Spain:
Goalkeepers: Casillas (Real Madrid), Reina (Liverpool), Diego López (Villarreal), David De Gea (Atletico Madrid), Valdés (Barcelona). >>>More
The main functions of the steam drum are: the connection hub of the three processes of working fluid heating, evaporation and superheating to ensure the normal water circulation of the boiler; There is a steam-water separation device and a continuous sewage discharge device inside to ensure the quality of boiler steam; There is a certain amount of water, a certain heat storage capacity, and the change rate of steam pressure is slowed down; There are pressure gauges, water level gauges, accident water discharge, safety valves and other equipment on the steam drum to ensure the safe operation of the boiler. >>>More