The plug of the power cord of the air conditioner is broken, how to repair it?

Updated on home 2024-02-12
17 answers
  1. Anonymous users2024-02-06

    Two repair methods:

    One is to cut off the burned-out air conditioner power plug, replace a *** 16A plug, and also put the power socket.

    Replace it with a 16A socket, if you need to plug and unplug the power plug of the air conditioner frequently, it is best to buy a power socket with a 16A switch, and when the air conditioner is not in use, you can turn off the switch directly to avoid frequent plugging and unplugging of the power plug and the phenomenon of poor contact.

    The second is to replace all the power cord plugs of the air conditioner, replace them with a *** one, and then remove the power socket on the wall and install an air switch directly.

    It is also possible to install a 16A air switch on the two-horse air conditioner.

    The reason for the burning of the air conditioner plug is mostly due to the poor quality of the power socket, and the metal sheet inside is too thin and deformed, resulting in poor contact with the plug and heating.

    Burnt. As long as there is no problem with the internal circuit of the air conditioner, the air conditioner can be used as usual.

  2. Anonymous users2024-02-05

    You can buy a plug, replace the previous bad plug, and pay attention to the wire color when connecting it with the previous connection; 220V is generally a 3-hole 16A socket; 380V 4-hole 25A, pay attention to match your original medicine when buying, whether it can't be plugged into the socket;

  3. Anonymous users2024-02-04

    Since air conditioners are high-power appliances, it is easy to be dangerous if there is poor contact.

    If the power cord plug is replaceable, it is enough to replace it with a brand new one. If it is a non-replaceable type, it is recommended that the entire power cord be replaced.

  4. Anonymous users2024-02-03

    During the warranty period, don't change it yourself, or the manufacturer will have a reason not to give you a warranty, you can buy a three-hole high-power plug by yourself and let the manufacturer replace it for you.

  5. Anonymous users2024-02-02

    The yellow that the landlord said should be yellow-green, that is the ground wire, the red is the fire line, and the blue is the zero line! The wiring of the air conditioner should correspond to the color on the terminal strip! Connect the two-color wire in the middle, that strand is the ground wire, and the rest.

  6. Anonymous users2024-02-01

    A loop of plastic bubbled around the plug, but the fuse of the plug was not broken. How long will this plug last?

  7. Anonymous users2024-01-31

    Of course you can, no problem.

    However, it should be noted that after cutting off the plug, the outer skin of the power cord connector should be peeled off, and the connection should be matched according to the polarity.

    Usually the brown wire is the live wire, which is connected to the L connector on the lower right side. The blue line is the neutral line, which is connected to the n-port on the lower left side. The yellow and green two-color wire is the ground wire, which can be connected to the interface above the middle.

    Label the connection as shown below:

  8. Anonymous users2024-01-30

    OK. However, due to the large current through the air conditioner, it should be noted that the new plug must be the same as the original plug current, and it is best to solder with an electric soldering iron when wiring, so as not to cause failure due to heating at the poor contact joint.

  9. Anonymous users2024-01-29

    It is okay to replace the plug with another one if it is broken, but it should be noted that the bearing capacity of the plug should be consistent with the original one, and it should not be too small, otherwise it will cause the plug to be destroyed.

  10. Anonymous users2024-01-28

    If the air conditioner plug is broken, you can cut the plug off and replace it with a new one. It's just that you must buy a plug with relatively high power, and change it casually, and it may break.

  11. Anonymous users2024-01-27

    Of course, this is possible, but don't change the plug wrongly, the plug of the air conditioner is 16 amp, and you must change it to a 16 amp plug.

  12. Anonymous users2024-01-26

    Yes, please pay attention to the same threads when connecting them together.

  13. Anonymous users2024-01-25

    Absolutely! But it is better that the power and carrying capacity should not be too small!!

  14. Anonymous users2024-01-24

    Cut the plug and replace it with a new one.

  15. Anonymous users2024-01-23

    Two repair methods:

    One is to cut off the burned out air conditioning power plug, replace a *** 16a plug, and at the same time replace the power socket with a *** 16a socket, if you need to plug and unplug the air conditioner power plug frequently, it is best to buy a power socket with a 16a switch, when not using the air conditioner, directly turn off the switch on it, to avoid frequent plugging and unplugging of the power plug is prone to poor contact.

    The second is to replace all the power cord plugs of the air conditioner, replace them with a *** one, and then remove the power socket on the wall, and directly install an air switch, and install a 16A air switch on the two air conditioners.

    The reason for the burning of the air conditioner plug is mostly due to the poor quality of the power socket, and the metal sheet inside is too thin and deformed, resulting in poor contact with the plug and heating and burning. As long as there is no problem with the internal circuit of the air conditioner, the air conditioner can be used as usual.

  16. Anonymous users2024-01-22

    Air conditioner power cord specification requirements:

    The area is the safe use range of wires: 2500-(2500x28% (*Huaicong line loss of regular brand wire)) = 1800W or less. It can supply a separate power to one air conditioner up to the nearest one.

    Generally, the effective refrigeration area of 1 HP air conditioner is 12m2; The horsepower is about 18m2; 2 hp is 22 m2 or more. Of course, there are some differences between brands.

    Therefore, rooms of more than 20 square meters should be equipped with air conditioners of more than 2 horses. And the power consumption of the 2 hp air conditioner is 1800W, which is greater when starting. For safety reasons, it is required to use wires with an area of 4mm2 or more.

    If the line used is a 2-horsepower air conditioner, it will be overloaded due to frequent overload power supply, resulting in accelerated wire aging, increased loss, and increased heat loss of the line, which is easy to cause disasters or other faults.

    How to connect the power cord of the air conditioner?

    Cut off the broken place, connect it directly, and wrap it with electrical insulating tape to ensure that the lead cherry blossoms will not be exposed to the rain outdoors. If you are not sure, ask an electrician friend to help, it doesn't cost money.

    If you want to change the new cable, you can open the case, connect the new draft cable according to the original fixed way, and buy a plug that can be wired at the other end of the new wire.

    In addition, the power cord of the air conditioner must be bought with the same specification and form as the original, and the old cord must be taken as a sample to the e-commerce mall to buy.

  17. Anonymous users2024-01-21

    It may be that the air conditioner consumes too much electricity and needs to reconnect the route to solve the problem; It may also be that the voltage of the air conditioner is unstable, and a household voltage regulator needs to be installed when using the air conditioner; It could also be that the aircon compressor is faulty, which can be solved by replacing the compressor. 1. If the power cord is damaged due to excessive power consumption of the air conditioner, it is necessary to purchase a good quality socket, and it is necessary to expand the operation path of the power cord to ensure the stability of the line, so that better conditions can be obtained. 2. The power of the air conditioner itself is not a constant value during operation, unlike the constant power of electric kettles or other electrical appliances.

    In the case of an inverter air conditioner, the frequency will be adjusted according to the room temperature. If it is a fixed-frequency air conditioner, the indoor temperature reaches the set value, the outdoor unit compressor will shut down, only the fan of the indoor unit works, when the temperature rises to the set value, the compressor will start again, the compressor in the process of starting the current is very large, generally several times the normal operation. 3. The burnout of the air conditioner power supply may be caused by the failure of the compressor, the compressor will produce various problems due to excessive load in the process of operation, and the compressor needs to be maintained when using the air conditioner, the compressor is the core part of the whole air conditioner, and once the problem occurs, it will directly affect the use effect.

Related questions
10 answers2024-02-12

The correct selection of household power cords not only directly affects the use effect and life of various household appliances, but also relates to the safety of life and property of each family, so it is necessary to understand the correct selection of household power cords. Common household power cords include RVB-70 PVC insulated parallel cord and twisted pair cord, RVZ-70 PVC insulated sheathed cord, RFB RFS type nitrile PVC composite insulated parallel cord and twisted pair cord, RHF type neoprene cord, etc. Different power cords should be used for different household appliances. >>>More

13 answers2024-02-12

At a glance on the motherboard, you can see the D port of the optical drive.

10 answers2024-02-12

Causes and solutions:

2. Cable problem (replug in, check VGA or DVI interface) 3. Display problem (check whether the electrical socket is powered on, if convenient, connect it to other computers to see if it is normal). >>>More

35 answers2024-02-12

In addition to the routing problem, it may be that the socket contact is poor.