Model: CWG60
Operating temperature: 0 40
Measuring range: -32shenhua08 600 Accuracy: 1 Repeatability.
Explosion-proof type: EXIB mine intrinsically safe type.
Power supply voltage: 9V DC (1 dedicated laminated battery).
Maximum open coal circuit voltage:
Maximum short-circuit current: .
-
The main use of the coal mine is CWH series infrared thermometer, which is divided into different models according to the different measurable temperatures, to give you a reference (this is CWH980, and there are other temperatures, which is probably the measured temperature is not a thorn, and other technical parameters are basically the same):
Performance metrics. Temperature measurement range.
0≤t≤100
100<t≤980
2% of the true value
Repeatability. ambient temperature at 24 1) resolution.
Alarm error. Not exceeded
Auxiliary display information.
Maximum, Minimum, Difference, Average.
Electrical characteristics. Operating voltage.
8~10)vdc
Operating current. 80ma
Structural characteristics. Dimensions.
220×120×56mm
Weight. Approximately 300g
Safety signs. Coal security certificate number.
MFA180210 explosion-proof certificate number.
-
Hello, Coal Mine. What are the main technical parameters of infrared thermometer? It is also necessary to divide the model, which generally means that 0 to 40 degrees Celsius is the optimal temperature. I don't know what model you're talking about?
-
Such as working environment, temperature requirements, image-related parameters, functions and displays, automatic warnings, etc. According to the specific needs of the coal mine, see whether the parameters meet the needs.
-
It is necessary to look at the size of the target and the distance coefficient of the thermometer, the distance from the measurement distance = the minimum diameter of the target * the distance coefficient, and also pay attention to the provisions of the minimum measurement distance.
The infrared thermometer book is the temperature of the surface, but the measurement is to know the emissivity of the measured target, and then set it in the thermometer menu. If the ambient temperature is very high, add an air purge, and a water cooling jacket. If the environment is very bad, use dual wavelength.
The distance coefficient is determined by the ratio of d:s, i.e., the ratio of the distance d between the thermometer probe and the target to the diameter of the target to be measured. If the thermometer has to be installed far away from the target due to environmental conditions, and small targets are to be measured, a thermometer with high optical resolution should be chosen.
The higher the optical resolution, i.e. the higher the d:s ratio, the higher the cost of the thermometer.
-
The English translation of infrared thermometer is: infrared thermometer
Infrared temperature measurement technology plays an important role in product quality control and monitoring, equipment fault diagnosis and safety protection, and energy saving in the production process. In the past 20 years, the non-contact infrared human body thermometer has developed rapidly in technology, the performance has been continuously improved, the function has been continuously enhanced, the variety has been increasing, and the scope of application has been expanding. Compared with the contact temperature measurement method, infrared temperature measurement has the advantages of fast response time, non-contact, safe use and long service life.
Non-contact infrared thermometers are available in three series: portable, ** and scanning, with a variety of options and computer software, each available in a variety of models and specifications. Among the various models of thermometers of different specifications, it is very important to choose the correct model of infrared thermometer for the user's sleepiness.
Infrared thermometer performance.
In order to obtain accurate temperature readings, the distance between the thermometer and the test target must be within the appropriate range, which is the area of the thermometer's measuring point. The farther you are from the target, the larger the spot size will be. The figure on the right shows the ratio of distance to spot size, or d:
s。On a laser sight type thermometer, the laser spot is above the center of the target and has a bias distance of 12 mm (inches).
Measure distance and spot size.
When setting the measurement distance, make sure that the target diameter is equal to or greater than the size of the spot to be measured. The distance between the "object 1" shown on the right and the gauge is squared because the target is slightly larger than the size of the spot being measured. And "object No. 2" is too far away.
-
There are roughly 5 models of mine infrared thermometers, namely: CWH425 infrared thermometer, CWH500 infrared thermometer, CWH550 infrared thermometer, CWH700 infrared thermometer, CWH760 infrared thermometer. There is a manufacturer below.
-
I'll tell you I don't know?
The mining belt conveyor protection device is designed by using dual bus control mode, and the network communication technology is used to design the ground to monitor and control the operation and fault status of the belt conveyor in the coal mine. The advancedness, reliability, ease of operation, and energy-saving lamps of the belt conveyor have been greatly improved compared with the comprehensive protection of similar belt conveyors. >>>More
Mining submersible pumps are mainly used for the drainage of the first pump room of the coal mine, the rescue drainage or the re-mining drainage after the flooding disaster of the coal mine, and the centrifugal pump is commonly used. When using the mining submersible pump, it is necessary to avoid frequently opening and closing the mining submersible pump. >>>More