You should close the valve of the heating pipe first to slow down the leakage, and then immediately contact the property maintenance personnel to report for repairs and wait for the property maintenance personnel to arrive.
-
It is necessary to close the valve first, and report to the heating company in time, and ask the heating company to send staff to repair it in time.
-
The pipe should be sealed so that it can prevent it from continuing to leak.
-
When a water leak occurs in a heating pipe, it is necessary to find the cause and take corresponding countermeasures according to the cause, which is actually as follows:
1.Damaged pipes.
Generally speaking, there are more leaks caused by damaged pipes, such as aging and disrepair of pipes. The quality of the pipes is weak, and the damage and leakage caused by these are recommended, and it is recommended to find technical professionals to dismantle and replace the heating pipes to prevent safety accidents. If the leakage caused by the sand hole in the pipe is unwilling to disassemble and replace the pipe fittings, then you can use raw tape to wrap the leak tightly, wrap it two more times, and then wrap it with aluminum and platinum on the outside, if the sand hole is not large, it can also be treated.
2.Loose pipe sockets.
When the construction team makes a mistake in the construction of the project and does not connect the heating pipe socket properly, then water leakage may occur, and the connection can be connected again. If the nut is loose and causes water leakage, the nut can be tightened, and if the nut of the socket is broken, a new nut needs to be removed.
Radiator blow mode:
1.Close the gate valve: Before the pressure test, turn off the watch back stop valve and the radiator single independent household main gate valve.
2.Fill with water: plug the leakage at the end of the pressure test pipeline and slowly fill the water, and discharge the vapor in the pipeline, and then carry out the sealing inspection after the pressure test pipeline is filled with water.
3.Pressure change: The pressure should be filled with a manual pump or an electric oil pump to change the pressure slowly, and the time of pressure change should not be less than 15 minutes.
4.Observation: After the working pressure is raised to the required inspection, the pressure is terminated, and the connection is observed to see if the water condition is detected.
5.Regulator tube: After the regulator tube, the gas pressure within 30 minutes does not exceed the standard.
6.Record: After the pressure test is completed, make the original record of the experiment and sign it to confirm.
1.The hydrostatic pressure of the pressure test is the pressure of the pipeline, and the experimental working pressure must not be less; If the pipeline pressure is lower, the working pressure of the hydraulic test is selected. The standard barometric test cannot be used as a substitute for the hydrostatic test.
2.After the pipeline is filled with water, the exposed nodes that have not been backfilled (including the connection position of the pipeline and the pipe fittings) are inspected, and the water leakage should be removed.
3.The length of the pipeline hydrostatic test is not suitable for more than 1000 meters. For the pipes equipped with fittings in the middle, the hydraulic test is not suitable for more than 500m according to the length of the section, and the pipes with different materials in the system software should be tested separately.
4.The end of the pressure test pipe section should be checked for firmness and stability, and during the pressure test, the support point equipment is not allowed to loosen and disintegrate, and the gate valve cannot be used as a connecting plate.
5.The charging pressure should be selected with industrial equipment with measurement and verification equipment, and the precision should not be less than the level (the larger allowable deviation should not exceed the larger scale, the measurement range should be the experimental working pressure times, and the case diameter should not be greater than 150mm.)
-
1) Generally, iron pipes will have sand holes due to long time and cause water leakage, which is more common and easy to solve. Wrap the radiator in a towel or rag and set aside a portion of it in the basin to allow the leaking water to be introduced into the basin.
2) The water leakage is more serious, and there are many water leaks, the suggestion is to change a PPR pipe, which is corrosion-resistant and heat-resistant, has a long life, and is cheap.
3) The pipeline is complex, it is difficult to change the pipe, and the leakage area is large, use a raw meal belt, wrap the leakage tightly, wrap it a few more times, and then wrap it with aluminum foil outside, if the sand hole is not big, it can also be solved.
4) You can use sealant, you need to close the heating valve to stop the water first; If there is no sealant, glass glue can also be used, and acid glass glue can not be used alone, acid glass glue has strong corrosiveness.
5) A fully automatic anti-leakage valve can be installed, which can be shut down immediately when there is water leakage, which can completely solve the problem of pipeline leakage.
6) If the water leakage is relatively serious, it is recommended to find a professional to solve it, because heating leakage can cause serious consequences.
-
1. The solution is as follows: the general iron pipe is caused by sand hole for a long time, which is more common and easy to solve, in the case that the radiator has trachoma, the radiator should be wrapped with a towel or rag first, and a part of it should be put into the basin, so as to introduce the leaking water into the basin. If the bicycle inner tube, you can cut it into a small section of about 1cm wide and about 50cm long, pull the inner tube strip hard at a distance of 3cm from the trachoma, and then wrap it around the trachoma 3cm by a buckle, and after 3-5 days, the trachoma will automatically rust to death.
2. The water leakage is more serious, and there are many water leaks, the best way is to change the PPR pipe, which is corrosion-resistant and heat-resistant, has a long life, and is cheap.
3. The pipeline is complex, it is difficult to change the pipe, and the leakage area is large, use a raw material belt, wrap the leakage, wrap it a few more times, and then wrap it with aluminum foil outside, if the sand hole is not big, it can also be solved.
4. You can use the sealant in the auto parts, and you need to stop the water from the heating pipe first; If there is no sealant, glass glue can also be used instead, but it should be noted that acid glass glue cannot be used, which is highly corrosive.
5. The above solutions are in the case that the water leakage is not serious, if the situation is more serious, we must notify the relevant professionals to solve it as soon as possible, after all, the heating leakage may cause serious consequences.
-
<>1. Find the cause of the heating pipe leakage. First, close the valve of the heating pipe and the valve of the water separator, and then open the valve of the water separator to release the pressure. 2. Investigate the cause of water leakage of heating pipes.
Find out whether there are cracks in the heating pipe, whether the interface is intact, etc., if it is because of the sand hole in the iron pipe, remove the inner tube of a section of the bicycle and deal with the leakage. If there is a sand hole in the heating pipe, wrap it in a towel and then treat it with a bicycle inner tube. 3. In the case of serious water leakage, you can directly choose to replace it with PPR pipe, which is corrosion-resistant, long-life, and low-cost, so as to avoid greater losses.
-
Hello dear! It's a pleasure to serve you. 1. If the heating pipe fails, the valve needs to be closed and the gas in the pipe needs to be discharged.
2. Trachoma appears in the pipe, which can be repaired by the inner tube of the bicycle. 3. If there is trachoma leakage in the branch pipe, it needs to be wrapped with a rag. 4. The pipeline leaks seriously and needs to be replaced with a new one.
5. If the connection gap leaks, stop the heating water supply and apply sealant. 6. If the individual is not handled well, continuous professionals are needed. 2. How to clean the heating pipe 1. Before cleaning the heating pipe, all the valves of the heating pipe need to be closed, whether it is the water inlet valve or the water outlet valve, it must be closed tightly.
2. After the valve is closed, it is necessary to find the filter equipment, which is mostly on the pipe of the heating meter and the water inlet valve. Along the front of the heating meter, about 10cm, you can see a diagonal downward head, inside which is where the filter is located. 3. Use a wrench to unscrew the plug on the outside of the filter, carefully take out the filter, and put it in clean water for cleaning.
After the treatment is clean, it can be installed in the pipe and the plug can be tightened. 4. After installation, it is necessary to open all the valves on the pipeline, as long as you hear the smooth sound of flowing water, it means that the exhaust air has completed the cavity noise, and you can empty the orange to use normally.
-
Kiss! Hello, happy to answer your <>
1. First of all, we need to understand the cause of water seepage, and then solve it in combination with the cause. Close the heating valve first, then open the air valve, and empty all the pressure inside. 2. It may be that the pipeline has been used for a long time, and there are some trachoma causing water leakage, which is not difficult to deal with.
Prepare an inner tube of the bicycle, wipe the surface clean, then stretch it in the leaky place, buckle it, and then tie it tightly with a wire, it will rust to death after a long time. 3. The water leakage is not particularly serious, and the surface can also be wiped clean first, and then pasted with a special sealant, which can play a role in sealing. In addition, glass glue can also be used, it is best to choose neutral, otherwise the acidic one will have a corrosive effect.
4. If the water leakage is more serious, in this case, it is best to replace it with a new pipe, replace it with PE material, which is better for its pressure resistance, and then wrap the raw meal belt, wrap it a few more times, and finally wrap it in aluminum foil. 5. If there is a problem of water leakage at the head, the joint needs to be replaced, especially at the interface of the valve, which is most likely to leak. 6. If there is water leakage in the valve, it may be that the sealing ring inside is damaged.
It is necessary to replace the gasket and then reinstall it back to burn it. 7. The last method, if you really don't know it, you can only ask professional personnel to come to the door to solve the maintenance. I hope I can help you <>
Do you have any other questions?
1. Hair constitutes sewer blockage: After the sewer is used for a period of time, the hair that usually takes a bath will hang on the pipe wall and accumulate too much, which will constitute a blockage, and the hair will usually constitute a blockage of the toilet floor drain, washbasin blockage, bathtub blockage, and shower room blockage. Therefore, when using it, it is necessary to cover the floor drain cover and other protective equipment, and if there is hair, you can pick it up and throw it into the trash. >>>More
Household water pipes, geothermal pipes leakage detection method: >>>More
The water pump plays the role of forced circulation. The flow rate of water in the pipeline is accelerated, so as to increase the heat exchange speed and improve the heat exchange effect. >>>More
Consumer water pipes are very important to maintain the safety of occupants, the standards are extremely high, and leaking water pipes need to be repaired immediately to avoid inevitable consequences. So what to do if the fire water pipe is leaking, and what is the standard of the fire water pipe, do you understand? Now let's take a look. >>>More
Clean with gauze paper: no oil. Water:
Then just glue it with AB glue! AB glue is another name for two-liquid mixed hardening rubber, one liquid is the glue, one liquid is the hardener, the two liquids can be hardened by mixing, and it is not necessary to rely on temperature to harden and mature, so it is a kind of hardening glue at room temperature, and it is sometimes used to make models. Generally used in industry. >>>More