Oceanwide Sanjiang 9116 or on the host of the alarm bus association, how to check how much smoke and temperature feel hand report falls? If you look at the specific data, it must be displayed on his monitor, or on the display board.
-
How many smoke detectors, temperature senses and hand reports are checked on the host of Oceanwide Sanjiang 9116 fire alarm controller? The button for the IR indicator and sensor should be queried. Click to search. FYI.
-
Sanjiang 9116 fire alarm controller host, how to check how many smoke and temperature sensors, how many hand reports, that can only look at other people's computer and one setting.
-
In Sanjiang, this fire alarm controller, how can the host check how many smoke and temperature sensors are received? This kind of thing can only be explained by professional firefighters.
-
How to check how many smoke detectors should be reported on the host of Oceanwide Sanjiang 9116 fire alarm controller? You can check this on the console's screen.
-
On the motherboard of this fire alarm controller, you can check the smoke sensor, temperature perception and hand feel.
-
What is the hand-reported that you want to check the smoke and temperature on the host of this fire alarm controller? You need a system setup to do so.
-
The smoke and temperature can be viewed on the host of Oceanwide Sanjiang 9116 fire alarm control system.
-
How to check how many smoke and temperature sensors are reported on the host of Oceanwide Sanjiang 9116 fire alarm controller?
-
How can you see the smoke detectors on the control host of Oceanwide Sanjiang 9116 fire alarm control console?
-
This total number of points does not exceed 3200 points.
-
There is a "bitmap" in the host, and when you open it, you can see what is in each circuit and how many devices.
-
I don't know, I've just started, the smoke detector of Yingkou Tiancheng installed today is 5 meters, the temperature is 5.5 meters, the hand report is meters from the ground, the sound and light are meters from the ground, and I know that this is probably it.
-
The isolation module is equivalent to a fuse, and it can generally carry about 30 points in the back, which includes the input module, output module, smoke sensor, temperature sensor, hand report, etc., and the points are easy to malfunction.
Of course, the signal line is installed with the isolation module first, and the line from the isolation module connects the field equipment such as the module, detector, and hand report, and the equipment behind it is not in any order.
-
From the perspective of hardware and software, there will be a logo on the circuit board of the general fire alarm controller; In addition, the specific number of loops can also be queried in the menu of the alarm controller.
-
The circuit card of the host controller will communicate with the smoke sensor, temperature sensor, hand report and other equipment through two wires and supply power, this kind of technology is called fire protection bus. These two lines are both communication lines and power lines, the principle is similar to DC low-voltage carrier, the power consumption of smoke detector equipment in the early years is large, the power supply capacity of this bus technology is not enough, and the smoke detector is still 4-wire equipment, but in the construction, the construction of four-wire equipment is too troublesome, and due to the poor environment of domestic construction, the construction technology level of the construction team is weak, and there are often problems such as the wrong line damaging the equipment and not being able to communicate. Later, the smoke detector manufacturers reduced the power consumption of the smoke detector, and now the smoke detector is a second-line equipment, but the traditional fire two bus technology, the power supply capacity can not be improved, and other node equipment that needs to emit light in the automatic fire alarm system still needs 4 wires (two power lines and two communication lines).
In recent years, there are some new two-bus technologies, such as powerbus bus technology, which supports high-current power supply, and there are chip-level applications, which can realize the needs of communication and power supply for all slave equipment through two wires, which greatly reduces the cost and time of construction.
-
From the controller to the field device 2 bus, look at how many bus devices can be brought by 1 loop of the circuit board of the equipment manufacturer, then the bus equipment smoke sensor, temperature sensor, hand report, fire hydrant button, input module, input and output module, sound and light alarm and other buses are 2, and the output device: input and output module, sound and light, etc. also need 2 24V power cords. The design drawings shall prevail.
-
The gas extinguishing system is separate from other equipment, and if you are in the gas extinguishing room, the smoke and temperature sensors will be activated at the same time.
-
Circuits are zoned, not by type of equipment, and you count the total number of points per floor or each fire zone, and you see how many zones a circuit can have, and then you reserve 20 to 40 percent of the points.
-
You have to use a dedicated dial. Or dial 1-1, 2-2, 3-4, 5-8, 6-16