When the air conditioner is heating, there will be a buffer time when it is just turned on, and the internal fan will not be turned on immediately, which is to prevent the cold air from blowing out. This time is about 3-5 minutes.
Because it is now necessary to power up the four-way valve to make it reversible. Another situation is that when the outdoor temperature is too low, the temperature of the air conditioning coil does not reach the set value, and the air conditioner will not start, and the waiting time will be relatively long. This is all normal.
When the outdoor unit is not in use, there may be rain, snow or ice attached to the fins, which will affect heat exchange. Defrosting before operation can solve this problem, heating operation in winter is equivalent to the exchange of indoor and outdoor units of air conditioning in summer, outdoor units absorb heat in a low temperature environment, frost will appear, if you are not in a hurry to melt the frost, it will affect the heat exchange, and then affect the heating effect.
-
Whether the air conditioner does not blow the air, or the heating does not blow the wind, or the cooling and heating do not blow the wind.
1.The refrigeration does not blow the wind, first confirm whether the downwind wheel is stuck. Open the panel, remove the middle frame, and then open the indoor electric control box, confirm whether the indoor motor plug-in is loose, loosen the plug-in and turn on the machine, not loose, use the multimeter to measure the resistance between each output of the motor, confirm whether the motor is burned, and finally find a maintenance worker to do it.
2.If it rotates freely, check the indoor temperature probe and tube temperature probe, because there is a process of cooling air during heating, and the pipe temperature is less than 25 degrees (different manufacturers) The fan will not rotate.
3.Refrigeration and heating do not blow air, as above, first check whether the wind wheel is stuck, and if it is stuck, you need to open the middle frame to find out the reason for stuck. Then confirm whether the motor is burned out according to the first article.
-
In winter, the air conditioner is turned on for heating, and there is no wind in the first few minutes, and if there is no problem with the air conditioner, the air generally starts to come out after six or seven minutes. This is normal. If there is no wind after more than ten minutes, then there is a problem with the air conditioner. You can contact the maintenance personnel to check it out.
-
<> Gree air conditioner does not have wind, there may be the following reasons:
Obstructed airflow: Check if the air inlet and unbridled air outlet of the air conditioner are blocked or blocked, and clean up if there are foreign objects.
Clogged filter: Check if the filter of the air conditioner is clogged, if the filter is too dirty, it will affect the air circulation and need to be cleaned or replaced.
Fan failure: Check whether the fan is working properly, if the fan is faulty, it needs to be replaced.
Control board failure: Check whether the control board is working properly, if the control board is faulty, it needs to be replaced or repaired.
Frosting of the condenser: If the condenser is frosted, it will cause poor air circulation and need to be addressed.
Poor pipeline connection between the internal and external units: Check whether the pipeline connection between the internal and external units is tight and whether there is leakage.
If you don't have a hail travel method to solve these problems yourself, it is recommended that you contact a professional maintenance personnel for repairs.
-
If the indoor unit does not ventilate in the air-conditioning refrigeration mode, it means that the fan motor or motor capacitance of the indoor unit is abnormal; In heating mode, if the indoor unit does not ventilate, the air conditioning and refrigeration system has a large abnormal state.
Causes: 1. The capacitance of the outdoor fan is broken, and the capacitance can be judged by energizing and discharging, and if it is bulging, it is broken.
2. If the outdoor fan is broken, will it be hot when touched by hand?
3. The fan does not have the electric defeat of 220, and you can directly put the 220 line and the 220 electricity of the compressor.
-
The lack of ventilation from the Gree air conditioner may be caused by a variety of reasons. Here are some suggestions and possible workarounds:
1.Clogged filter: The air conditioner filter may become clogged due to dust accumulation, resulting in a decrease in air output. Cleaning the filter can solve this problem. Follow the air conditioner's manufacturer's instructions for filter cleaning.
2.Temperature sensor failure: The temperature sensor is responsible for monitoring the indoor temperature and sending it to the air conditioning controller. If the sensor is faulty, the air conditioner may not be able to ventilate properly. Please check the sensor and replace it if necessary.
3.Air Conditioner Controller Failure: The air conditioner controller is responsible for receiving the signal from the temperature sensor and controlling the air outlet according to the signal. If the grinding controller fails, the air conditioner may not be able to produce air. Please contact a professional service person to inspect and repair the air conditioner controller.
4.Fan problems: A faulty fan can cause a decrease in the air outflow. Check the fan for loose, worn, or damaged fans. If there is a problem, replace the fan.
5.Obstructed airflow: The air vent of the air conditioner may be blocked by objects, resulting in obstruction of the air outlet. Please make sure that the air outlet is unobstructed.
6.Mode setting issues: Check your air conditioner's mode settings to make sure it's set to the correct mode. If the air conditioner is set to supply air mode, it will only produce air and not cool and heat.
Try the above suggestions and solutions to see if the air conditioner is ventilating. If the problem persists, please contact the after-sales service or professional maintenance personnel of Gree Air Conditioner for inspection and repair. Maintaining regular maintenance and upkeep of your air conditioning equipment can help ensure that it is functioning properly and extending its lifespan.
-
There are many possible reasons why the Gree air conditioner does not have wind, and here are some common ones:
Clogged filter: If the air conditioner filter is clogged with dust, dirt and other substances, it will affect the air circulation and cause the air conditioner to not ventilate.
Fan failure: If the air conditioner fan cannot operate normally due to aging or other reasons, it will also cause the air conditioner to not ventilate.
Condenser failure: The condenser is one of the most important components in the air conditioner, and if it fails, it will lead to a decrease in the cooling effect, which in turn will affect the air circulation.
Fluorine leakage in the pipeline: Leakage of refrigerant or failure of the pipeline of the air conditioner will lead to a decrease in the cooling effect, so it will also affect the air outlet of the air conditioner.
Control panel failure: The control panel is the core component of the air conditioner operation, and if it fails, it may cause the air conditioner to not work properly.
If you encounter this situation, it is recommended that you check whether the filter is clean first, if the problem is not solved after cleaning the filter, you need to ask a professional maintenance personnel to overhaul the air conditioner.
-
There can be a variety of reasons for the problem of Gree air conditioner not having air, and here are some common situations and solutions::
1.Fan failure: Check if the fan of the air conditioner is working properly, if not, it needs to be replaced or repaired.
2.Clogged filter: Check whether the air conditioner filter is clean, if the filter is too dirty, it will cause the airflow to be blocked and the air cannot be discharged normally. Clean the filter and try again.
3.Fluorine leakage in the internal ridge pipeline: If the internal pipe leaks fluorine, it will lead to poor refrigeration effect, which in turn will affect the air outlet. At this time, it is necessary to call in a professional technician to repair and refill the refrigerant.
4.Control panel failure: Check if the control panel of the air conditioner is normal, if there is a fault, it needs to be replaced or repaired.
5.Air conditioner power failure: Check if the power supply of the air conditioner is normal, if there is a problem with the power supply, it needs to be repaired or replaced.
In short, if you encounter the situation that the Gree air conditioner does not ventilate, you can check the above aspects first, if you still can't solve the problem, it is recommended to contact a professional air conditioner maintenance personnel for inspection and maintenance.
-
The lack of air from the Gree air conditioner may be caused by a variety of reasons, such as the air conditioner filter is blocked, the temperature is abnormal, and the outside temperature is too low. You can try to clean the air conditioner's rotten filter, adjust the position of the temperature sensor, try to heat the environment, and so on to solve the problem.
-
1. The indoor unit is not connected to the power supply.
It is possible that the air conditioner does not ventilate because the air conditioner is not really connected to the power supply. We can check in detail whether the plug of the air conditioner is loose, whether there is a problem with the remote control of the air conditioner, if the plug of the air conditioner is loose, or there is a problem with the remote control of the air conditioner, then the air conditioner will naturally not be windy.
2. The temperature of the indoor heat exchanger is low.
It is also possible that the air conditioner does not ventilate because the temperature of the heat exchanger placed in the room is relatively low. In winter, if the temperature of the indoor heat exchanger is low, the air conditioner will automatically stop supplying air to prevent cold air from blowing.
3. Frost of outdoor heat exchanger.
It is also possible that the air conditioner does not have air due to frost formation in the heat exchanger placed outdoors by the air conditioner. When using air conditioning for heating in winter, if the indoor temperature is relatively low or the humidity is relatively high, then a large amount of frost will appear in the heat exchanger placed outdoors, and then the air conditioner will automatically start the defrosting function, and the indoor air conditioner will naturally stop supplying air, or the speed of air supply is generally about three to twelve minutes. In the process of defrosting, the air conditioner generally emits more water vapor or water flow.
4. Turn on the dehumidification mode indoors.
It is also possible that the air conditioner does not ventilate because the air conditioner has turned on the dehumidification function. When the dehumidification function of the air conditioner is turned on, the indoor unit fan of the air conditioner will stop running and stop supplying air, so the air conditioner will naturally not be able to supply air. The reason why the indoor unit fan of the air conditioner stops running is to prevent the condensation of water during the dehumidification process from evaporating, so as to prevent the indoor temperature from rising.
5. The air-conditioning compressor is damaged.
Once the air conditioner compressor is damaged, the air conditioner will naturally not supply air, so you need to ask professional maintenance personnel to come to the door for inspection and maintenance.
-
The indoor unit is not connected to the power supply, some netizens may be more depressed, the air conditioner has been plugged in, and it has been turned on with the remote control, why does the air conditioner not ventilate? In fact, it is very likely that the indoor unit is not really connected to the power supply, you can check whether the plug of the indoor unit is loose, whether the remote control of the air conditioner is damaged, the indoor unit of the air conditioner is not connected to the power and the remote control of the air conditioner has problems, and the indoor unit of the air conditioner will not be ventilated.
If the air conditioner turns on the dehumidification mode in summer, the indoor unit fan of the air conditioner will sometimes stop, and the air supply will be stopped at this time, and the air outlet will not come out, which is mainly to prevent the condensate from evaporating during the dehumidification process, so as to inhibit the temperature rise.
If the air conditioner compressor is damaged, it is normal for the air conditioner outlet to be out of the air at this time, and the air conditioner compressor is broken, and the air conditioner needs to be repaired.
Questions. Okay thank you. You're welcome.
-
The air conditioner should be heated about 5-10 minutes later than the cooling before the air is blown, because it is not yet the time to warm up. The four-way valve is not opened, or the four-way valve itself is stuck, or the electronic control does not output the voltage of the four-way valve. There may be a lack of fluorine, and more fluorine is used for heating than for cooling.
The room tube temperature sensor may be damaged.
It is also possible that the air conditioner blades have not been cleaned for a long time, and the wind blowing out is small due to excessive dust.
-
If the Gree air conditioner does not have air, then have you not switched to the refrigeration mode? If you turn it to the cooling mode and it still doesn't get windy, you can ask the appliance repairer to fix it.
-
Broken heat sensor in the evaporation chamber? Mine is the same, turn on the air conditioner for more than 10 minutes and there is no wind, and the air conditioner refrigeration pipes are all ice.
-
It is the air outlet of the air conditioner that is blocked, and when the machine is turned on, take the paper roll into the air outlet and poke it; There will be a lot of dust particles, like black snowflakes, and there should be wind in the middle.
-
Problems with the power supply.
The cause of the voltage.
Whether the line is aging.
Power supply: Pay attention to whether the outdoor unit has working sound, including whether the fan and compressor of the outdoor unit are running normally. If the outdoor unit fan is running, it means that the control circuit is normal, and at this time, it is necessary to observe whether the compressor is working, if the compressor is not working, you need to check whether the power supply is normal.
The reason for the voltage: when the electricity is at its peak, the voltage is not enough is definitely normal, if the air conditioner can not be turned on, it is necessary to check whether the external power supply has electricity, or whether the voltage has reached the rated voltage, to ensure that the air conditioning voltage is normal. If it is not due to the low voltage, it is necessary to check whether the indoor unit and outdoor unit of the air conditioner are connected correctly.
Whether the circuit is aging: Because with the extension of time, there will be a certain amount of wear and tear in all aspects of the parts of the air conditioner, as well as whether the wiring of the main board of the indoor unit is correct, and whether the main board of the internal unit needs to be replaced.
-
Dear users, hello! We're glad to answer your questions! The reasons why the air outlet of Gree air conditioner does not vent are as follows:
1. Generally speaking, it is easier to have air conditioning outlets in winter. Because if the outside temperature is lower than 0 degrees, the outside unit of the air conditioner will be frosted or even frozen. When the air conditioner is turned on for heating, about 8 to 12 minutes are used for "defrosting", at which point the room temperature may also be lowered.
2. The hidden blower is damaged. Check that if the blower is damaged, the blower should be replaced immediately. 3. The fuse is blown out.
At first glance, you can see that the only way is to replace the fuse. 4. The air outlet pipe is blocked. In this case, it is necessary to check the outlet pipe for garbage, and it should be cleaned up immediately.
5. The filter screen and condenser are blocked. The rotten ears should be cleaned regularly. 6. There is a shortage of oil in the motor bearing.
Regular check-ups are recommended. 7. The problem of wind wheels.
It may be a problem with the air conditioning line or your home circuit, this situation requires Gree professional service personnel to come to the door for inspection and troubleshooting, please click on the self-service report or call Gree National Unified After-sales Service **4008365315 feedback your needs and suggestions.
1.The drain is clogged. The most common cause of dripping water in an air conditioner's indoor unit is a problem with the drain pipe. >>>More
Gree air conditioner. The external machine does not work due to the following reasons: >>>More
Everyone knows that the air conditioner is controlled by the remote control, and if you are not careful, you will press the wrong button, and the air conditioner remote control will generally have a lock button function to prevent accidental contact and change the operating status of the air conditioner. I don't know if you have encountered the phenomenon of air conditioning being locked in the use of air conditioning, if you encounter this phenomenon of air conditioning locking, how should we solve it? The following will introduce to you the method of air conditioner unlocking, and after learning the method of air conditioner unlocking, you can unlock the air conditioner by yourself. >>>More
The e-share mode of Gree air conditioner automatically sets the temperature between 26-28 degrees, which can avoid setting too low and running all the time. 1.The e-share mode of Gree air conditioner is based on the environmental sensor of the air conditioner, which will automatically change according to the ambient temperature, which can well avoid low temperature settings and keep running, reduce noise and airflow, and make sleep more comfortable. >>>More