Striker water heater malfunction A9 and flameout

Updated on home 2024-03-18
10 answers
  1. Anonymous users2024-02-06

    1. When the induced current of the flame detection (feedback electrode) is weak, it is judged that the burner has no fire, resulting in the interruption of the program.

    Solution: Adjust the height of the feedback electrode.

    2. The combined electrode fails to discharge.

    Solution: Repair the combination electrode.

    3. The ignition pulse spark is normal and does not ignite.

    Solution: Repair the ignition pulse.

  2. Anonymous users2024-02-05

    Overheat protection. The reason is that the surface of the temperature measurement probe is seriously scaled and the temperature measurement response is sluggish. The phenomenon before the failure is that the actual water temperature is significantly higher than the set temperature to the point where it feels hot, and then suddenly turns off.

    The temperature of the heat exchange surface of the water heater is very high, and there will be scale when the water flows over, and after a long time, there will be a lot of scale attached to the inner surface of the heat exchanger, which will accumulate over time, resulting in the blockage of the hot water pipeline, which will cause the hot water output to become smaller (the phenomenon of small water pressure) and the hot water output time will become longer. At the same time, the hot water outlet is equipped with a temperature sensor, which is the narrowest place in the water heater waterway, which is easy to accumulate scale, resulting in temperature sensing lag, resulting in hot and cold water outlets, and serious hot water overheating, causing overheating protection to go out.

    It is recommended to clean and descale first, buy a set of gas water heater online without removing the scaler, use it to inject descaling agent into the water heater to clean the inside of the water heater can be solved, the operation is simple and convenient, use it to clean it regularly in the future, when this problem can be avoided again. A lot of people have used it, and it really works.

  3. Anonymous users2024-02-04

    The A9 fault of the H4+ of the Qianfeng water heater is generally a power failure, if there is sometimes an F1, it is a failure of the outlet water temperature probe and needs to be replaced. If you are not a professional, do not disassemble the machine for maintenance, otherwise it will be repaired more and more badly, the front water heater manufacturer national repair ** is 400-699-9988 If the insurance period is one year old or find a contract to repair **will be much cheaper We are the forward repair shop near the Gaosheng Bridge in Chengdu If you need to come to the door to repair you can contact **81257356

  4. Anonymous users2024-02-03

    Before using the electric water heater, the water heater must be filled with water before turning on the power supply; Turn off the electric water heater after taking a shower, and keep the water heater turned off at all times, <>

    This minimizes energy consumption and thus maximizes energy savings.

  5. Anonymous users2024-02-02

    The 24V power supply is faulty, and the 24V transformer is broken, and it may be the motherboard.

  6. Anonymous users2024-02-01

    The Striker water heater shows an A9 fault, which is usually caused by a failed ignition of the water heater. This can be caused by blocked gas lines, faulty igniters, insufficient gas pressure, etc. In order to solve this question and answer question, you can try the following steps:

    Check that the gas valve is open and the gas pipeline is unblocked. Check that the igniter is working properly and that there is no electrical spark. Check the water heater's air supply lines for blockages or other issues.

    If the above steps do not solve the problem, it is recommended to contact professional and technical personnel to carry out repairs. In any case, please do not attempt to repair or disassemble the water heater yourself, as this may lead to safety incidents. It is advisable to seek professional help.

  7. Anonymous users2024-01-31

    Summary. Hello dear, happy to answer your <>

    The Striker Water Heater shows that the A9 is faulty, usually due to poor combustion. The specific reasons may be the following: insufficient gas**:

    It may be that the gas pipeline is blocked, the gas pressure is insufficient, etc., which affects the combustion effect. Incomplete burner cleaning: After long-term use, some impurities and dirt may accumulate inside the burner, resulting in poor combustion.

    At this point, the burner needs to be cleaned and maintained. Ignition failure: If the igniter fails or the battery is low, it can also cause poor combustion.

    Water Heater Sensor Failure: Water heater sensor is an important part of monitoring combustion, and if the sensor is faulty or damaged, it can also lead to poor combustion.

    The forward water heater burns for a few seconds and then turns off to show what the A9 is faulty.

    Hello dear, Zhizen is happy to answer your <>

    The A9 failure of the front water heater is usually caused by poor combustion and lap molding. The specific reasons may be the following: insufficient gas**:

    It may be that the gas pipeline is blocked, the gas pressure is insufficient, etc., which affects the combustion effect. Incomplete burner cleaning: After long-term use, some impurities and dirt may accumulate inside the burner, resulting in poor combustion.

    At this point, the burner needs to be cleaned and maintained. Ignition failure: If the igniter fails or the battery is low, it can also cause poor combustion.

    Water heater sensor failure: The water heater sensor is an important part of monitoring the combustion situation, and if the sensor is faulty or damaged, it will also lead to poor combustion.

    Dear, in view of this situation, it is recommended that the user first check the cleaning of the gas ** and burner, if there is no problem, you can contact the professional bureau of the water heater maintenance personnel for repair and replacement of parts. When using the water heater daily, users also need to pay attention to regular cleaning and maintenance to ensure the normal operation of the water heater. <>

  8. Anonymous users2024-01-30

    Summary. Striker water heater A9 failure** is usually caused by ignition failure. Here are some possible causes and solutions for ignition failure:

    1.Insufficient gas supply: Check that natural gas or LPG** is stable, has air bubbles, and has been used up.

    2.Blocked gas lines: Check if the gas lines are stuck with foreign objects or blocked by sediment, which needs to be cleaned and maintained.

    3.Wrong circuit connection: Make sure the circuit is connected correctly and there are no loose or disconnected places.

    4.Spark plug failure: Check if the spark plug is damaged or detached and needs to be replaced or reinstalled.

    5.Exhaust system problems: Exhaust system failure to work properly will lead to a backlog of flue gas, which will affect ignition.

    The air ducts need to be cleaned and the exhaust air cleared. If you are unable to solve the above problems, please contact a professional repair personnel for assistance. At the same time, pay attention to safety, please follow the correct operating procedures and safety regulations when using the water heater.

    Displaying A9 usually indicates ignition or combustion fault initiation. Possible causes include ignition failure, valve pin failure, gas circuit blockage, oxygen sensor failure, etc. It is recommended that you contact the after-sales service center of Qianfeng Water Heater for professional technicians to diagnose and repair.

    Make sure to close the gas valve and disconnect the power supply before making any repairs to ensure safety.

    I'm a maintenance guy.

    Say a little about professional failure analysis.

    Striker water heater A9 failure** is usually caused by ignition failure. Here are some possible causes and solutions for ignition failure:1

    Insufficient gas supply: Check that natural gas or LPG** is stable, has air bubbles, and has been used up. 2.

    Gas lines are blocked: Check if the gas lines are stuck with foreign objects or sediments, and need to be cleaned and maintained. 3.

    Wrong circuit connection: Make sure the circuit is connected correctly and there are no loose or disconnected places. 4.

    Spark plug failure: Check if the spark plug is damaged or detached and needs to be replaced or reinstalled. 5.

    Exhaust system problems: Exhaust system failure to work properly will lead to a backlog of flue gas, which will affect ignition. The air ducts need to be cleaned and the exhaust air cleared.

    If you are unable to solve the above problems, please contact a professional repair personnel for assistance. At the same time, pay attention to safety, please follow the correct operation procedures and safety regulations of Zen when using the water heater.

  9. Anonymous users2024-01-29

    Blind problem with power shed. Solution: Check whether the AC power plug indicator is on, and first rule out the problem of the power supply part.

    2. Reason 2: solenoid valve failure. Workaround:

    If the ignition is only heard when the ignition is heard, there is no solenoid valve "click" magnetic suction sound, it may be that the solenoid valve is damaged or aging, the solenoid valve is aging, it will be uncontrollable, it can be sucked at the beginning of the ignition, and the fire can be hit, but then it is closed and extinguished; It may also be that the gas pressure is too high or too low, and the output pressure of the cylinder pressure reducing valve will be too high or too low in the water heater using cylinder gas. It is more likely that the solenoid valve has dirt. The solenoid valve cannot be overgased, and the gas (natural gas, liquefied petroleum gas, artificial gas) cannot come out, and it cannot come out, so that the ignition cannot catch fire. Before confirming the quality of the solenoid valve, it is necessary to confirm whether the ignition control circuit is normal, if there is a fault, the solenoid valve cannot be controlled.

    3. Reason 3: Electric igniter failure. Workaround:

    One of the pulse igniters and the controller is faulty, and neither the water heater can ignite. 4. Reason 4: The main controller is faulty.

    Solution: If the motherboard is faulty, you need to contact the after-sales maintenance personnel for timely repair or replacement. 5. Reason 5:

    Thermistor bad solution: Replace the thermistor with a new one.

  10. Anonymous users2024-01-28

    Hello dear, there are multiple reasons for the fault code A9 of the forward water heater; One of the reasons: power supply problems. Workaround:

    Check whether the AC power plug indicator is too bright, and first rule out the problem of the power supply part. Reason 2: Solenoid valve failure.

    Solution: If only the ignition sound is heard when ignition, and there is no solenoid valve "click" magnetic absorption sound, it may be that the solenoid valve is damaged or aging, and the solenoid valve is aging and disturbed, and it will be uncontrollable. It may also be that the gas pressure is too high or too low, and the water heater using cylinder gas will have the output pressure of the cylinder decompression valve too high or too low, and the water heater cannot be ignited; It is more likely that the solenoid valve has dirt. Reason 3:

    Faulty electric igniter. Solution: One of the pulse igniters and the controller is faulty, and neither water heater can ignite.

Related questions
18 answers2024-03-18

My AO Smith water heater has been used for 5 years, has been leaking, and can not be repaired after sale, and then saw on the Internet that Haier's water heater has a very good reputation, so I bought Haier's water heater, the next day Haier's master installed it, only to find that the old water heater could not be removed because of rusty bolts, at that time I and the master were desperate, and finally the master took out an angle grinder from the toolbox, and it took almost three hours to remove the old machine, and then installed the new water heater, during which the master did not complain, Finally, he also said that the dismantling of the old machine is free of charge, and there is no service fee. Kudos to Master and Haier.

10 answers2024-03-18

How to choose an electric water heater:

1. When choosing an electric water heater, consumers should choose a brand electric water heater. Choosing a brand electric water heater can better solve the "safety" point, the general brand electric water heater will have a built-in patented anti-electric wall technology, real-time safety protection, not only to solve the problem of leakage of the product itself, but also to completely eliminate all the hidden dangers of electric shock caused by the live ground wire, and cut off the hidden danger of electric shock. >>>More

10 answers2024-03-18

Before cleaning the water heater, cut off the power supply, use the impact force of water to clean the water heater, drain all the water in the water heater before cleaning, and then tear off the hardware such as the shower, leaving only the cold and hot water pipes, and then install one end on the faucet, and the other pipe is used for drainage. Repeat it a few times to clean the water heater. Regularly carry out system sewage discharge to prevent pipeline blockage; And clean the water tank to ensure that the water quality is clean. >>>More

11 answers2024-03-18

The water heater shows E1, which means that the ignition has failed or has stalled halfway. >>>More

3 answers2024-03-18

The light of solar energy is early, but the sales have not been good, and the coverage rate is not high. >>>More