The function of the grounding transformer is to provide an artificial neutral point for the system with no neutral point, which is convenient for the use of arc suppression coil or small resistance grounding mode, so as to reduce the size of the capacitance current to the ground when the grounding short-circuit fault occurs in the distribution network, and improve the power supply reliability of the distribution system.
The grounding transformer is referred to as the grounding transformer, and according to the filling medium, the grounding transformer can be divided into oil type and dry type; According to the number of phases, the grounding variable can be divided into three-phase grounding transformer and single-phase grounding transformer. China's grounding transformer usually adopts Z-type wiring (or zigzag wiring), in order to save investment and substation space, usually add a third winding on the grounding transformer to replace the transformer used, and supply power to the equipment used in the substation.
Working characteristics of grounding transformer:
1. The zero-sequence impedance is low to ensure the output of the zero-sequence current;
2. High excitation impedance to reduce no-load current;
3. Low no-load loss to save energy consumption for daily operation.
The above content refers to Encyclopedia - Grounding Transformer.
-
It provides an artificial neutral point for the system with no grounding at the neutral point, which is convenient for the grounding mode of arc suppression coil or small resistance, so as to reduce the capacitance current to the ground when the grounding short circuit fault occurs in the distribution network, and improve the power supply reliability of the distribution system.
Foreign grounding transformers usually adopt or Z-type connection, used for 10kV non-grounding system, constituting the grounding protection of the distribution network, when the system grounding fault occurs, the grounding transformer presents high impedance to the positive sequence and negative sequence current, and low impedance to the zero sequence current, so that the grounding protection operates reliably.
Background of the use of grounding transformers
In the 6kV, 10kV and 35kV power grids in the power system, the neutral point is generally not grounded. The low-voltage side of the main transformer in the power grid is generally triangular and there is no neutral point that can be grounded.
When a single-phase grounding fault occurs in the neutral point non-grounding system, the line voltage triangle is still symmetrical, and the power system can continue to supply power to the user for 1 to 2 hours, and the capacitance current is relatively small (less than 10A), which will not cause intermittent arcing, and some instantaneous grounding faults can disappear by themselves, which is very effective in improving the reliability of power supply and reducing power outages.
However, with the continuous expansion of the urban power grid and the continuous increase of cable outlets, the capacitance current of the system to the ground increases sharply, and the capacitance current flowing through the fault point after single-phase grounding is large (more than 10A). The arc is not easy to extinguish, easy to excite ferromagnetic resonance overvoltage and produce interstitial arc grounding overvoltage, which may lead to insulation damage, line tripping, and accident expansion.
The above content refers to Encyclopedia - Grounding Transformer.
-
The main function of the grounding transformer: it is used to connect the grounding resistance. When the system has a grounding fault, it has high impedance to the positive sequence and negative sequence currents, and low impedance to the zero sequence currents, so that the grounding protection can operate reliably.
The grounding transformer is referred to as the grounding transformer, and according to the filling medium, the grounding transformer can be divided into oil type and dry type; According to the number of phases, the earthing transformer can be divided into three-phase grounding transformer and single-phase grounding transformer.
Three-phase grounding transformer: the function of the grounding transformer is that when the neutral point of the system is type wiring or Y-type wiring can not be drawn, the neutral point is used to add arc suppression coil or resistance, this kind of transformer adopts Z-type wiring (or zigzag type wiring), the difference with ordinary transformer is that each phase coil is divided into two groups and is wound in reverse direction on the phase magnetic column, so that the advantage of connection is that the zero sequence magnetic flux can flow along the magnetic column, and the zero sequence magnetic flux of the ordinary transformer is along the leakage magnetic circuit. Therefore, the zero sequence impedance of the Z-type grounding transformer is very small (about 10), while the ordinary transformer is much larger. According to the regulations, when an ordinary transformer with an arc suppression coil is used, its capacity shall not exceed 20% of the transformer capacity.
The Z-type transformer can be equipped with an arc suppression coil of 90% 100% capacity, and the grounding transformer can be equipped with an arc suppression coil and a secondary load, which can replace the transformer used, thereby saving investment costs.
Single-phase grounding transformer: Single-phase grounding transformer is mainly used for neutral grounding resistance cabinets of generators and transformers with neutral points, so as to reduce the cost and volume of resistance cabinets.
-
For the medium voltage system of 3-35kV, most of the neutral point non-grounding operation mode is adopted in China to improve the reliability of power supply; However, with the increase of the system (the increase of transformer capacity and outgoing wire), when single-phase grounding occurs, the grounding capacitor current will be very large, which may cause "arc grounding overvoltage", damage equipment insulation, and cause equipment damage accidents.
However, most of the secondary coils of the step-down transformers that form the medium-voltage system in China are angle-shaped wiring, and there is no neutral point, so that the arc suppression coil cannot be installed; So people designed the "grounding transformer", the grounding transformer is a "star" wiring transformer, through this star-wiring transformer, man-made a "neutral point", so that the arc suppression coil can be connected to this artificial neutral point, to solve the problem that the medium voltage system has no neutral point.
Therefore, the grounding transformer is a transformer with a primary coil for star wiring and a neutral point for the installation of an arc suppression coil.
-
The core and other accessories of the transformer are in the electric field around the winding, if not grounded, the core and other accessories will inevitably induce a certain voltage, under the action of the applied voltage, when the induced voltage exceeds the discharge voltage to the ground, the discharge phenomenon will be generated. In order to avoid the internal discharge of the transformer, the iron core should be grounded.
-
The main reason for grounding is to prevent static electricity on electrical appliances.
-
What is the function of a grounding transformer? What about station changes?
The grounding transformer is to provide an artificial neutral point for the power system that is not grounded at the neutral point, and then it is grounded through an arc suppression coil to form the grounding protection of the power system together with the arc suppression coil. Prevent the intermittent arc at the grounding point from causing overvoltage to the system and amplifying the accident when the system is single-phase grounding fault. The station transformer refers to the step-down transformer that provides low-voltage power and lighting for the substation.
The station can sometimes be used to take into account the grounding change.
-
The transformer grounding wire, you need to connect the live wire and the neutral wire of the transformer first, and the specific operation steps are as follows:
1. Prepare the transformer.
2. Turn the transformer over and connect it to the live wire first.
3. Connect the zero line again.
4. The live wire and the neutral wire are wired, the 220 terminal represents the live wire, the 0 terminal next to the 220 terminal represents the neutral wire, and the 0 terminal next to the 6 terminal represents the ground wire.
5. Connect the ground wire on the 0 terminal next to the 6 terminal, and the wiring is completed.
-
m2 or so, with an iron plate in the transformer neutral point lead-out.
The neutral point (N) of the transformer is connected with the transformer housing and reliably grounded, and the protective ground wire (PE wire) is separately drawn from the grounding point.
2. The function of the grounding transformer is to wire or type in the system.
When the neutral point of the Y-wiring cannot be drawn, the neutral point is used.
Add arc suppression coil or resistor, this type of transformer adopts Z-type connection.
Wire (or zigzag wiring), the difference between ordinary transformers.
Yes, each phase coil is divided into two groups that are wound in reverse direction around the phase column.
The advantage of such a connection is that the zero-sequence magnetic flux can flow along the magnetic column, while the zero-sequence flux of an ordinary transformer flows along the magnetic leakage magnetic circuit, so the zero-sequence impedance of the Z-type grounding transformer is very small (about 10), while the ordinary transformer is much larger.
-
1. The function of the grounding transformer is to provide a neutral point for the system where the neutral point is not grounded, which is convenient for the use of arc suppression coil or small resistance grounding mode, so as to reduce the size of the ground capacitance current when the grounding short circuit fault occurs in the distribution network, and improve the power supply readability and pure reliability of the distribution system.
2. The grounding transformer is referred to as the grounding transformer, and the grounding transformer can be divided into oil type and dry type according to the filling medium; According to the number of phases, the grounding variable can be divided into three-phase grounding transformer and single-phase grounding transformer.
-
The function of the grounding transformer is to connect the arc suppression coil when the neutral point of the system is type wiring or the type Y wiring cannot be drawn out.
Principle: The grounding transformer adopts Z-type wiring, and the difference between the ordinary transformer is that each phase coil is wound on two magnetic columns, so the advantage of this connection is that the zero-sequence magnetic flux can flow along the magnetic column, and the zero-sequence magnetic flux of the ordinary transformer flows along the leakage magnetic circuit, so the zero-sequence impedance of the Z-type grounding transformer is very small 10, while the ordinary transformer is much larger.
The intermittent extinguishing and re-ignition of the single-phase grounding arc will produce arc grounding overvoltage, the amplitude of which can reach 4U (U is the peak value of normal phase voltage) or higher, and the duration is long, which will cause great harm to the insulation of electrical equipment and form breakdown in the weak part of the insulation; Causing significant losses.
Due to the dissociation of air caused by continuous arcing, the insulation of the surrounding air is destroyed, and interphase short circuits are prone to occur.
It may be that a vortex has been generated.
For example, if an insulated wire is wound around an iron core, and after the alternating current is turned on, the current becomes a closed loop in the metal block. >>>More
Full-power step-up transformers and step-down transformers can be used interchangeably. If the transformer reaches full power, it will not cause damage, if the copper-clad aluminum wire or aluminum wire transformer cannot be used in this way, because the power of these two types of transformers is not as sufficient as the power of the all-copper wire transformer. >>>More
The isolation transformer is a safety power supply, which is generally used for machine repair and maintenance, and plays the role of protection, lightning protection and filtering. >>>More
Generally speaking, the capacity of 1kVA can drive the left and right motors (and the power factor of the motor. >>>More
The former operates at a higher frequency, resulting in a smaller number of coils and uses a ferrite core. >>>More