If the waste fire extinguisher is not disposed of properly, it is easy to cause, so do not dispose of it without authorization.
At present, there are few relevant national and local regulations on scrapped fire extinguishers, and there is no mandatory provision on who should do so, resulting in some fire extinguishers being scrapped acquisition stations, or being refurbished by small black fire extinguisher workshops, and it is very dangerous to re-enter the market.
The fire department suggests: If the fire extinguisher has clearly stipulated the scrapping period, it must be forced to scrap when the age is reached. Scrapped fire extinguishers should be processed in a centralized manner at the manufacturer or regular fire product testing and maintenance center, and scrapped fire extinguishers should be treated with pressure relief, punching, and complete removal of cylinders.
The following eight tips can detect a fire extinguisher.
There is a life limit for fire extinguishers from use to scrapping, so how can we know if the stored fire extinguishers have been scrapped? A fire extinguisher in one of the following 8 situations should be scrapped.
1.The cylinder is seriously corroded (the rust area is greater than or equal to 1 3 of the total area of the cylinder), and there are pits on the surface.
2.The cylinder is obviously deformed, and the mechanical damage is serious.
3.There are cracks in the head, and there is no pressure relief mechanism.
4.The structure of the cylinder is unreasonable for the flat bottom.
5.Portable without intermittent jetting mechanism.
6.There is no name of the manufacturer and the date of manufacture, including the nameplate falling off, or although there is a nameplate, the name of the manufacturer can no longer be seen, or the date and month of manufacture can not be identified by the steel seal.
7.The cylinder has repair marks such as soldering, brazing or patching.
8.Burned by fire.
-
At present, there is no special ** company in China, and now it mainly flows to waste stations and fire factories, but I am in Beijing specializing in waste fire extinguishers.
-
Fire extinguishers must be scrapped under the following circumstances:
1. The cylinder is subjected to hydraulic test, and the unqualified one must be scrapped, and repair welding is not allowed;
2. Serious corrosion of the cylinder (the patent leather falls off in a large area, and the rust area is greater than or equal to one-third of the total area of the cylinder) or the connection parts and the bottom of the cylinder are seriously corroded;
3. The inner buckle head does not have (or is not installed) the gas relief screw and the fixing screw;
4. The carbon dioxide fire extinguisher of the handwheel valve must be replaced with the pressure handle valve; For fire extinguishers with a fire extinguishing dose greater than or equal to 4kg, the head with intermittent spraying mechanism should be replaced or a spray gun should be installed. those that cannot be replaced should be scrapped;
5. The cylinder is seriously deformed;
6. The structure is unreasonable (such as the flat bottom of the cylinder; The gas storage cylinder is external, and the air intake pipe enters the dry powder fire extinguisher inside the cylinder from the cylinder body);
7. There is no name of the manufacturer and the date of manufacture (including the decal falling off, or although there is a decal, but the name of the manufacturer and the date of manufacture can not be seen clearly);
8. The Ministry of Public Security or the provincial (municipal, district) public security and fire departments order to prohibit sales and maintenance.
Article 24 of the Fire Protection Law of the People's Republic of China Fire protection products must meet national standards; If there is no national standard, it must meet the industry standard. It is forbidden to produce, sell or use unqualified fire-fighting products and fire-fighting products eliminated by the state.
The fire protection products that are subject to compulsory product certification in accordance with the law shall be produced, sold and used only after the certification body with statutory qualifications has passed the certification in accordance with the mandatory requirements of national standards and industry standards.
The catalogue of fire protection products subject to compulsory product certification shall be formulated and published by the product quality supervision department in conjunction with the public security organs.
Newly developed fire protection products that have not yet formulated national standards and industry standards shall be produced, sold and used only in accordance with the measures stipulated by the first-class product quality supervision department in conjunction with the first-class public security organs, and can only be produced, sold and used after technical appraisal to meet the fire safety requirements.
In accordance with the provisions of this article, the fire protection products that have passed the compulsory product certification or technical appraisal shall be announced by the fire protection agency of the public security organ.
The scrapping life of dry powder fire extinguishers fire extinguishers must be scrapped if they reach the following years from the date of manufacture >>>More
Fire extinguishers have water and dry powder fire extinguishers, dry powder fire extinguishers are low, 3 kg and 4 kg fire extinguishers are about forty or fifty yuan each, when buying, you should go to the regular fire equipment store to see, and select a fire extinguisher with a certificate that does not expire.
How to use the fire extinguisher and precautions How to use the fire extinguisher and precautions. >>>More
The power switch can be classified into two categories, one is two-wire, the other is three-wire, but the two-wire power switch and the three-wire power switch are not big, only one more ground wire, and the ground wire is also no voltage, but there is one more protection function for the power supply, to prevent the power switch from burning out due to excessive power. In addition, whether it is a three-wire or a two-wire connected wire, there must be a neutral wire and a live wire, and the only wire with more is the ground wire. The abbreviations of the neutral wire and the live wire are L and N respectively, which are 220V alternating current, and the abbreviation of the ground wire is FG, which is directly connected to the earth and has no voltage. >>>More
The method of using the hand-held dry chemical fire extinguisher is: 1 Lift the fire extinguisher to the appropriate position from the fire source 2 first turn the fire extinguisher upside down several times to loosen the dry powder in the cylinder, 3 then aim the nozzle at the most violent place of the flame, 4 pull out the safety pin, press down and press the dry powder fire extinguishing agent in the 5 cylinders will be sprayed out.