The Gree air conditioner shows what is going on with the E2

Updated on Financial 2024-03-23
23 answers
  1. Anonymous users2024-02-07

    Gree air conditioner E2 is anti-freezing protection, plate heat exchanger anti-freezing protection, evaporator anti-freezing protection, anti-low temperature, the specific cause of the fault needs to be detected and dealt with by service personnel. Please click "Appointment Service" to self-service repair or call Gree National Unified After-sales Service**4008365315 feedback your needs and suggestions.

  2. Anonymous users2024-02-06

    Gree 5P display E2 refers to the inner anti-freezing protection. You need to do the following steps:1

    Clean your internal filter and external condenser, be sure to rinse them well. 2.Turn off the power supply to the air conditioner, and then power it on to let it work、Take a closer look at your internal evaporator to see if it is frosty?

    If there is frost and the internal and external units are cleaned, then you should check whether the connecting pipes between the internal unit and the external unit of your air conditioner are deflated or folded, and if the pipeline throttles and causes poor refrigerant circulation, it will also form an anti-freezing protection. 3.Charge the pressure gauge to check what is the following pressure of your system, under normal circumstances, the pressure is normal at 4-5 pressures, if the pressure is too low, it will also form protection.

    4.If the above check is not good, then you need to open the panel of the internal machine, take off the temperature sensing head of the evaporator, be careful not to touch the evaporator, and hang it in the air. Turn on the air conditioner for a while, and if it doesn't show E2, then there is a problem with the resistance of this sensor and it needs to be replaced.

  3. Anonymous users2024-02-05

    Gree air conditioner shows that E2 is the air conditioner has entered the state of anti-freezing protection, which means that the evaporator temperature of the air conditioner is too low, which means that the cold air dissipation capacity of the air conditioner is insufficient, and the air conditioner filter element needs to be cleaned.

    A few common causes of anti-freeze protection:

    1. The filter screen is dirty and blocked.

    2. The surface of the evaporator is dirty and the air volume is small.

    3. Lack of fluorine in the system.

    4. There is a flattened place in the connecting pipe.

    5. The indoor fan does not rotate or the tuyere is blocked.

    6. The indoor ambient temperature is lower than 18 degrees.

    7. The temperature sensing head of the tube is broken.

    8. The plug of the tube temperature sensing head is not plugged in properly.

  4. Anonymous users2024-02-04

    Gree air conditioner display E2 means "internal unit anti-freeze protection". That is, when the evaporator temperature is too low, the air conditioner enters a protective state in order to protect itself. If there is no problem with the temperature sensing head when E2 occurs, it means that the evaporator is dirty or the air speed of the internal unit is too low.

    There are several common causes of anti-freezing protection: 1. The filter screen is dirty and blocked. 2. The surface of the evaporator is dirty and the air volume is small.

    3. Lack of fluorine in the system. 4. There is a flattened place in the connecting pipe. 5. The indoor fan does not rotate.

  5. Anonymous users2024-02-03

    Answer: The E2 failure of the Gree air conditioner refers to the failure of the anti-freezing protection of the evaporator, the reason for this situation may be caused by the indoor fan not turning or the air outlet is blocked, or it may be caused by the indoor ambient temperature temperature below 18 degrees, or it may be caused by the broken head of the tube temperature sensor, or because the plug of the pipe temperature sensor head is not plugged in properly, and if it is caused by the abnormal control loop, it will also lead to the E2 failure of the Gree air conditioner.

    Here's how to fix it:

    1. If the indoor fan does not rotate or the tuyere is blocked, it needs to be dredged.

    2. If the indoor ambient temperature is lower than 18 degrees, it needs to be adjusted.

    3. If the tube temperature sensing head is broken, it needs to be repaired.

    4. If the plug of the tube temperature sensor is not plugged in well, it needs to be plugged in.

    5. If the control loop is abnormal, you need to contact the professional after-sales service personnel of Gree Air Conditioner for on-site inspection and maintenance.

  6. Anonymous users2024-02-02

    1. When the air conditioner shows the E2 logo, it means that the anti-freeze protection function has been activated inside the air conditioner; The reason why E2 is displayed is generally because the wind speed and temperature of the internal unit are too low due to equipment failure, and the evaporator automatically enters the protection state in order to avoid damage to the air conditioner, and the user needs to restart the air conditioner after the fault is handled, so that the air conditioner can operate normally.

    2. It may be because the evaporator is dirty and cannot dissipate heat normally, resulting in the temperature of the air conditioner being too low, and the air conditioner will enter a state of self-protection and anti-freezing at low temperature.

    3. After checking the filter, if you find that it is not very dirty, then you do not need to clean it, and the reason why E2 is displayed is likely to be a control failure or a system failure.

  7. Anonymous users2024-02-01

    A few common causes of anti-freeze protection:

    1. The filter screen is dirty and blocked.

    2. The surface of the evaporator is dirty and the air volume is small.

    3. Lack of fluorine in the system.

    4. There is a flattened place in the connecting pipe.

    5. The indoor fan does not rotate or the tuyere is blocked.

    6. The indoor ambient temperature is lower than 18 degrees.

    7. The temperature sensing head of the tube is broken.

    8. The plug of the tube temperature sensing head is not plugged in properly.

    9. The control loop is abnormal.

    10. Capacitor C7 leakage.

    Workaround for e2 to appear:

    1. Check the filter. If it is dirty, it needs to be cleaned, and if it is not, the internal evaporator needs to be cleaned.

    2. Analyze whether it is a control failure or a system failure

    First look at whether there is frost in the evaporator of the internal machine during normal operation, if it is frosty, it means that the system is faulty. Remove the chamber tube thermob from the evaporator, if E2 does not appear, it means that there is a system problem.

    If there is no frost and the pressure (which is normal) is normal, there is a problem with the tube temperature sensor in the control system.

    3. Check whether the indoor ambient temperature is too low, whether the speed of the indoor fan is too low, whether the indoor evaporator is too dirty, whether the system is blocked, and whether the inner pipe thermometer is misprotected due to open circuit.

  8. Anonymous users2024-01-31

    The Gree air conditioner displays E2, which usually indicates that the indoor temperature sensor is faulty or the wiring connection is poor. It is recommended to contact a professional technician for overhaul and repair.

  9. Anonymous users2024-01-30

    If the air conditioner at home shows the E2 logo, it may be that the air conditioner has activated the antifreeze protection function.

  10. Anonymous users2024-01-29

    As far as I know, the Gree air conditioner shows E2 indicating that the indoor temperature sensor is faulty.

  11. Anonymous users2024-01-28

    When the Gree air conditioner displays the E2, the fault is that it has entered the state of anti-freezing protection.

    Anti-freezing protection is the state of protection that the air conditioner enters for self-protection when the evaporator temperature is too low. If there is no problem with the temperature sensing head, it means that the evaporator is dirty or the air speed of the internal unit is too low.

    A few common causes of antifreeze protection and solutions:

    First, the filter screen is dirty and blocked. Clean the filter and you're done.

    Second, the surface of the evaporator is dirty and the air volume is small. Clean the evaporator and you'll be fine.

    3. System failure. When the evaporator of the internal machine is frosted during normal operation, it means that the system is faulty. Remove the chamber tube thermob from the evaporator. If e2 does not appear after removal, it is also a system failure. Need to find after-sales maintenance.

    Fourth, the control system failure. There is no frost in the evaporator of the internal machine when the normal work is carried by Gongchun Li, and the pressure (normal) is also normal, which means that there is a problem with the tube temperature sensor in the control system. Need to find after-sales maintenance.

  12. Anonymous users2024-01-27

    The Gree air conditioner shows E2, which usually indicates that the indoor temperature sensing mold is faulty. This can be due to a damaged, loose, or poorly connected sensor. When the air conditioner detects a malfunction of the indoor temperature sensor, it will automatically stop cooling or heating to avoid more serious failures.

    If your Gree air conditioner shows E2, you can try the following methods::

    Check if the room temperature sensor is loose or poorly connected, and if so, reconnect it.

    Check if the room temperature sensor is damaged, and if so, replace it with a new one.

    If the above methods do not solve the problem, it is recommended to contact a professional air conditioner maintenance personnel for inspection and repair.

  13. Anonymous users2024-01-26

    The meaning of the E2 displayed by Gree air conditioner is that the air conditioner has entered the state of anti-freezing protection, which is that the evaporator temperature of the air conditioner is too low, and the cold air dissipation capacity of the air conditioner is insufficient, and the air conditioner filter needs to be cleaned.

    A few common causes of anti-freeze protection:

    1. The filter screen is dirty and blocked.

    2. The surface of the evaporator is dirty and the air volume is small.

    3. Lack of fluorine in the system.

    4. There is a flattened place in the connecting pipe.

    5. The indoor fan does not rotate or the tuyere is blocked.

    6. The indoor ambient temperature is lower than 18 degrees.

    7. The temperature sensing head of the tube is broken.

    8. The plug of the tube temperature sensing head is not plugged in properly.

  14. Anonymous users2024-01-25

    The Gree air conditioner displays E2, which means that the air conditioner has entered the anti-freeze protection. It is because the temperature of the air conditioner's evaporator is too low. This is because the air conditioner's cold air distribution capacity is insufficient. Only the aircon filter cartridge needs to be cleaned. The specific steps are as follows:

    1. Turn on the air conditioner panel.

    2. Pull out the air conditioner filter.

    3. Remove the air conditioner filter.

    4. Clean the air conditioner filter.

    5. Reinstall the air conditioner filter.

  15. Anonymous users2024-01-24

    1. E2: anti-freezing protection of indoor unit evaporator.

    Possible cause: Fault e2:

    The first step is to determine whether it is a control failure or a system failure, you can first take out the indoor tube temperature package from the evaporator, if it does not appear, it means that it is a system problem;

    The second step is to check whether the indoor ambient temperature is too low, whether the indoor fan speed is too low, whether the indoor evaporator is too dirty, and whether the system is blocked.

    2. Boot display failure**E2: The indoor pipe thermostat is broken, resulting in false protection.

    3. Run for a period of time when the compressor and outdoor fan are stopped, and the indoor fan is still running, and the fault is displayed **E2 (no display for light box type):

    1) Check whether the evaporator is frosted, if it is frosted, it will show fault **e2.

    2) If the evaporator is not frosted, it may be that the position of the indoor tube temperature head is wrong, resulting in the local temperature being too low, and the tube temperature head can be moved out and tried again.

    3) The indoor tube temperature sensor package is broken or broken.

    4) It could also be a malfunction of the display itself or a problem with the control board.

    5) The filter is too dirty.

    6) The system is dirty and blocked.

    7) The speed of the indoor motor is too low.

  16. Anonymous users2024-01-23

    What is the reason for the appearance of E2 in the air conditioner.

  17. Anonymous users2024-01-22

    Refrigeration overload protection, i.e. the evaporator of the internal machine is frozen.

    Cause: The sensor cable is broken.

    The filter screen of the internal machine is dirty and blocked.

    The reduced capacity of the internal fan leads to a low speed of the internal fan.

    The back of the evaporator of the internal unit is too dirty, resulting in the evaporator not being ventilated.

    Sensor resistance drift.

  18. Anonymous users2024-01-21

    Gree E2 is an indoor anti-freezing protection, and the air conditioner should be used to pay attention to maintenance. It is recommended that you clean the filter of the inner machine frequently.

  19. Anonymous users2024-01-20

    E2 refers to the internal machine anti-freezing protection.

    Solution:1Clean the filter before the evaporator.

    2.Take off the antifreeze thermometer head of the internal unit and put it in hot water, turn on the machine for trial operation, if E2 is not displayed, then there is a problem with the sensor and needs to be replaced.

    3.If all of the above is normal, it means that there is a problem with the circuit board and needs to be replaced.

  20. Anonymous users2024-01-19

    Hello, the appearance of "E2" in the household air conditioner may be due to the anti-freezing protection plate heat exchanger anti-freezing protection Evaporator anti-freezing protection Anti-low temperature, the reason may be the poor return air of the indoor unit, the evaporator or filter screen is dirty, and the internal fan speed is low; refrigerant leakage; The resistance value of the tube temperature sensing temperature package is abnormal, and the specific cause of the fault needs to be determined by a professional master after testing.

  21. Anonymous users2024-01-18

    Air conditioner failure**Gree: inverter cabinet E1-E5

    E1: Press overcurrent, overheating, exhaust over-high, module protection;

    E2: Indoor anti-freezing protection;

    E3: Indoor temperature temperature sensor package open, short circuit;

    E4: Indoor pipe temperature open, short circuit;

    e5: Indoor and outdoor communication failure.

    Fixed frequency machine failure**:

    E1: Compressor high pressure protection.

    E2: Evaporator anti-freeze protection.

    E3: Compressor low pressure protection.

    E4: Compressor exhaust temperature is too high protection.

    E5: Overcurrent (Low Voltage Protection).

    KF-60L WAK Split Vertical Cabinet Room Air Conditioner Failure** E1 1 There is an obstacle in front of the condenser.

    2 The control loop is constant.

    3 Start cooling when the outdoor ambient temperature is higher than 43 degrees.

    4. The pressure of the high-pressure pipe is over-pressurized, and the high-pressure switch is activated.

    E2 1 The indoor fan does not rotate or the tuyere is blocked.

    2 The indoor ambient temperature is lower than 18 degrees.

    3. The temperature sensing head of the tube is broken.

    4. The plug of the thermometer plug is not plugged in properly.

    5 The control loop is constant.

    6 Capacitor C7 leakage.

    LF-12WAK Split Vertical Cabinet Room Air Conditioner Fault** E1 1 There is an obstacle in front of the condenser.

    2 The control loop is constant.

    3. The three-phase power supply is out of phase.

    3 Start cooling when the outdoor ambient temperature is higher than 43 degrees.

    4 The working current is over-the-top and the protector action or the pressure of the high-pressure pipe is over-the-top and the high-voltage switch action is e2 1 The indoor fan does not rotate or the tuyere is blocked.

    2 The indoor ambient temperature is lower than 18 degrees.

    3. The temperature sensing head of the tube is broken.

    4. The plug of the thermometer plug is not plugged in properly.

    5 The control loop is constant.

    6 Capacitor C7 leakage Gree air conditioner fault ** Gree: inverter cabinet E1-E5

  22. Anonymous users2024-01-17

    What is the reason for the appearance of E2 in the air conditioner.

  23. Anonymous users2024-01-16

    Do the math how much it will cost you to renovate your home

    Gree air conditioner brand is loved by consumers on the market, Gree air conditioner will inevitably have problems after a long time, and various letters will generally be displayed when there is a problem with the air conditioner**, so what does it mean that Gree air conditioner displays e2? Let's find out together.

    What does the Gree air conditioner mean when it shows e2.

    1. When the "E2" letter is displayed on the display screen of Gree air conditioner, it means that the air conditioner has entered the state of anti-freezing protection, and the air conditioner will automatically enter the state of self-protection in order to protect itself and avoid freezing damage. There are many reasons why Gree air conditioner enters the state of anti-freezing protection, and the treatment methods will be different if the reasons are different.

    2. When the "E2" letter is displayed on the display screen of the Gree air conditioner, we should first check whether the filter screen of the air conditioner is blocked, if the filter screen of the air conditioner is blocked by dust, sundries and other dirt, it will cause the "E2" letter to be displayed on the display screen of the Gree air conditioner, and then the problem can be solved as long as the air conditioner filter is cleaned up.

    3. If the filter of the air conditioner is not dirty, then you should check the evaporator of the air conditioner in detail, when the temperature of the air conditioner evaporator is very low, the air conditioner will automatically enter the state of self-protection in order to protect itself from freezing damage, then the display screen of the Gree air conditioner will naturally display the letter "E2". At this time, you only need to clean the evaporator of the air conditioner.

    4. If the evaporator of the air conditioner is still frosting when the air conditioner is in normal operation, then it means that the system of the air conditioner is faulty, resulting in the "E2" letter displayed on the display screen of the Gree air conditioner. We can take the room tube temperature pack out of the evaporator of the air conditioner, if the air conditioner does not show the letter "E2" on the display, it means that the system is faulty.

    5. If there is no frost in the evaporator of the air conditioner, and the pressure display is also a normal value, then it means that the pipe temperature sensor in the air conditioning control system is faulty, resulting in the display screen of the Gree air conditioner showing the letter "E2".

    6. If it is determined that there is no problem with the temperature sensing head of the air conditioner, then it may be because the evaporator of the air conditioner is dirty or the wind speed of the air conditioner is too low, causing the Gree air conditioner to automatically enter the state of self-protection, and the "E2" letter will naturally be displayed on the display screen of the Gree air conditioner. At this time, as long as the evaporator of the air conditioner is cleaned, the problem can be solved.

    The above is a detailed introduction to what the E2 air conditioner means when it is displayed, I hope it can help you better understand the Gree air conditioner. When the Gree air conditioner shows E2, the cause should be found first, and then the method suitable for fierce sales should be taken according to the actual situation.

    Enter the area and get the decoration for free**].

Related questions
12 answers2024-03-23

Gree air conditioner display E2 is anti-freezing protection, plate heat exchanger anti-freezing protection, evaporator anti-freezing protection, anti-low temperature, the specific cause of the fault needs professional service personnel to come to the door to detect and troubleshoot, please click on the self-service report or call Gree national unified after-sales service**4008365315 feedback your needs and suggestions.

15 answers2024-03-23

The e-share mode of Gree air conditioner automatically sets the temperature between 26-28 degrees, which can avoid setting too low and running all the time. 1.The e-share mode of Gree air conditioner is based on the environmental sensor of the air conditioner, which will automatically change according to the ambient temperature, which can well avoid low temperature settings and keep running, reduce noise and airflow, and make sleep more comfortable. >>>More

17 answers2024-03-23

When the air conditioner is heating, there will be a buffer time when it is just turned on, and the internal fan will not be turned on immediately, which is to prevent the cold air from blowing out. This time is about 3-5 minutes. >>>More

12 answers2024-03-23

It may be a problem with the air conditioning line or your home circuit, this situation requires Gree professional service personnel to come to the door for inspection and troubleshooting, please click on the self-service report or call Gree National Unified After-sales Service **4008365315 feedback your needs and suggestions.

10 answers2024-03-23

What does it mean when the air conditioner shows E1.

After about 8 to 10 minutes of cooling of the open machine, E1 is the fault of the air conditioner (compressor current protection, compressor overheating protection, outdoor unit exhaust temperature too high protection, outdoor unit phase sequence current protection circuit board is broken). >>>More