Does low water pressure and air pressure affect the use of wall hung boilers

Updated on home 2024-04-16
12 answers
  1. Anonymous users2024-02-07

    The working pressure of the wall-hung boiler is generally above, and this number refers to the minimum working pressure of the heating pipe. If the furnace you buy has a pressure switch, when the water pressure is lower than the minimum working pressure, the wall-hung boiler will not work (as long as the water is replenished to the heating pipe when the water pressure is normal, the wall-hung boiler can work normally); For the wall-hung boiler with domestic hot water function, the water pressure is small and the domestic hot water may not be produced, because the pressure is small, the water flow is small, and the water flow sensor on the wall-hung boiler of many brands is flow-type, and the signal value does not meet the requirements, and the control system will not control the ignition of the wall-hung boiler, which is mainly to prevent overheating and dry burning. If the flow rate can be reached, it will almost work.

    Gas pressure is not a problem, the rated pressure of the civil natural gas pipeline is 2000Pa (20cmh2O), 1000Pa wall-hung boiler can be burned, the low pressure will only affect the size of the fire, the output power is insufficient, resulting in the heating temperature can not go up, but the low pressure is mainly in the peak of gas consumption, such as afternoon meal time. For the heating of the room is basically unaffected. Unless the pressure in your home is low 24 hours a day, which is a common phenomenon, then you have to let the natural gas company increase the pressure.

    Besides, your house is on the 7th floor, and the specific gravity of natural gas is greater than that of air, and the pressure upstairs must be a little greater than the pressure downstairs.

  2. Anonymous users2024-02-06

    Water pressure: the minimum required action pressure of the wall-hung boiler is bar (kg, that is, kilograms), as long as the water pressure of the wall-hung boiler is increased to , that is, kilograms during the initial commissioning), the tap pressure is not enough, the manufacturer usually uses a self-priming pump to assist the user to pressurize, the initial stage of commissioning within 3 days to a week, the water pressure may be unstable, you can use the pump to pressurize at any time, after the water pressure is stable, the pressure of the wall-hung boiler heating system will be maintained at this water pressure, which can usually be maintained for 2 months to a heating season, if the water pressure shown by the wall-hung boiler water pressure gauge has been 1——, No matter how much external pressure is, the wall-hung boiler can be heated normally, but if the water volume is too small, it is more problematic to use hot water. Usually, the wall-hung boiler has a minimum water flow rate of 3L minutes, that is, when the water flow is less than 3 minutes, the wall-hung boiler cannot provide hot water.

    Gas pressure: usually the proportional combustion wall-hung boiler has higher pressure requirements, when the natural gas pressure is lower than 1500pa (equivalent to 150mmh20, that is, 150 mm water column), it can not be used normally, if it is a sectional combustion wall-hung boiler, as long as there is more than 400pa (equivalent to 40 mmh20, that is, 40 mm water column) above the air pressure, as for the air pressure in your home, you can let the natural gas company to test, you can also let the service staff of the wall-hung boiler after-sales outlets test. Then make a decision on whether to buy and what configuration to buy a wall-hung boiler.

    To sum up, the impact of water pressure on the wall-hung boiler is not fatal (as long as it can reach the above, the minimum can not be lower, and then it will affect the life), the key is the gas pressure, which determines your winter warmth!

  3. Anonymous users2024-02-05

    The flow stabilization device is specially designed inside the wall-hung boiler system, and when the water flow rate changes due to the fluctuation of water pressure and air pressure, the water flow rate can be adjusted according to individual needs. It will not affect the use of wall-hung boilers! More knowledge of wall-hung boilers can be reached.

    Let's take a look.

  4. Anonymous users2024-02-04

    You have to find a professional to test it.

  5. Anonymous users2024-02-03

    When wall-hung boilers. When the water pressure pointer is lower than the red warning line, it is particularly prone to dry burning, and after a long time, the wall-hung boiler will be seriously damaged by loose skin, and even need to replace the wall-hung boiler. At the same time, users should pay attention to the fact that when there is no one at home for a long time, they should do a good job of anti-freezing measures for the wall-hung boiler to prevent the wall-hung boiler from being frozen due to the freezing of warm water, which will affect the daily life needs.

    In the face of the low water pressure of the wall-hung boiler, the wall-hung boiler should be turned off, the power supply should be cut off, and then the heating system should be checked for water leakage to ensure that the inside of the system is completely sealed, and then rotate the handle of the water injection water replenishment valve counterclockwise for a circle, and at the same time observe the change of the water pressure gauge, when the water pressure gauge pointer falls between, clockwise.

    Tighten the handle of the water filling valve, and finally turn on the wall-hung boiler.

  6. Anonymous users2024-02-02

    Most of the wall-hung boilers (including different brands) are used in kilograms (that is, the pressure gauge on the pressure gauge as the protective pressure value of the machine operation, as long as the water pressure is higher, it can be used with confidence, and the machine will be shut down if it is lower; There are also a few models that are protected by differential pressure, and the pressure value is slightly lower.

  7. Anonymous users2024-02-01

    As long as the boiler is operating normally, there is no shortage of water, the water pressure gauge is to remind the user of the size of the water pressure in the boiler system, which is convenient to confirm when replenishing water, the boiler has water shortage protection, if there is a lack of water, the boiler does not work.

  8. Anonymous users2024-01-31

    If there is no error, you can use it. Some manufacturers add a water pressure switch to the system, and if it is below a certain pressure, it will directly stop the fire and report the error.

  9. Anonymous users2024-01-30

    It doesn't matter, as long as the water pressure is higher, you can use it with confidence.

  10. Anonymous users2024-01-29

    Summary. Dear We will be happy to answer your <>

    The air pressure of the wall-hung boiler will drop. The wall-hung boiler has a heating function, and the wall-hung boiler can be depressurized by discharging water to the heating system and reducing the pressure. Close the water supply valve of the wall-hung boiler first, then open the exhaust valve on the floor heating water separator or the exhaust valve above the radiator, and wait until the pressure of the wall-hung boiler is reduced, and then close the exhaust valve.

    salute [than heart] <>

    <> will the air pressure drop when the water is discharged from the wall-hung boiler?

    Dear We will be happy to answer your <>

    The air pressure of the wall-hung boiler will drop. The wall-hung boiler has a heating function, which can be used to depressurize the wall-hung boiler by discharging water and lowering the pressure of the heating system. First close the water supply valve of the wall-hung boiler, then open the exhaust valve on the floor heating water separator or the Zaona exhaust valve above the radiator, and wait until the pressure of the wall-hung boiler is reduced, and then close the exhaust valve and answer the stool.

    salute [than heart] <>

    <> extended information: wall-hung boiler is the abbreviation of gas wall-hung boiler, the full name is gas wall-hung heating furnace, is a kind of water heater with natural gas as energy, with anti-freezing protection, anti-dry burning protection, accidental flame-out protection, high temperature protection, pump anti-jamming protection and other safety protection measures. The gas wall-hung boiler has a strong home heating function, which can meet the heating needs of multi-bedrooms, and each room can be set at will to set a comfortable temperature according to the needs, and the high slag can be decided to turn off the heating in a room separately according to the needs, and can provide large flow of constant rotten coarse temperature sanitary hot water, which is used in family bathing, kitchen and other places, which is economical and practical.

    salute [than heart] <>

  11. Anonymous users2024-01-28

    Hello dear <>: The air pressure of the wall-hung boiler will decrease, which may lead to a decrease in water pressure, and there are three main reasons. 1. If the sealing of the pipeline is not tight, it is easy to cause water leakage and cause the water pressure to drop.

    Therefore, it is necessary to check whether the pipe of the wall-hung boiler is leaking, and if there is water leakage, it is necessary to make up the leakage in time. 2. There is gas inside the wall-hung boiler, which will cause the water pressure to drop. In the process of replenishing water, it is easy to mix some gas, so it is necessary to open all the exhaust valves that are flushed by Tongyin, and then close after the gas is discharged.

    3. If there is no timely replenishment of water, it will lead to water shortage and water pressure drop. You need to open the water replenishment valve of the wall-hung boiler, and add the appropriate water to carry the crack, and wait for it to be added.

  12. Anonymous users2024-01-27

    Without any impact, there is now a protective structure design.

    When the ignition switch of the wall-hung boiler enters the working state, the fan starts first to form a negative pressure difference in the combustion chamber, and the wind pressure switch sends the finger to the pump, and after the pump starts, the water flow switch sends the instruction to the high-pressure differential punch electrical appliance and sends the instruction to the gas proportional valve after starting, and the gas proportional valve starts to start.

    The gas proportional valve and the wind pressure switch and the flue gas induction switch are interlocked, the combustion chamber has a certain negative pressure gas, the proportional valve can work, when the flue gas induction switch can not detect the exhaust gas discharge in 5 seconds, the gas proportional valve will be cut off to stop the gas supply, so as to ensure the safe use of gas.

Related questions
14 answers2024-04-16

Advantages of wall-hung boiler heating.

1.The advantage of Anerrui wall-hung boiler heating is that it is energy-saving and environmentally friendly, because it does not waste a lot of heat on the pipeline like central heating. Comparatively speaking, wall-hung boiler heating improves heating efficiency. >>>More

12 answers2024-04-16

1.The difference between condensing wall-hung boiler and ordinary wall-hung boiler - comparison of energy saving: >>>More

12 answers2024-04-16

Made of copper and aluminum composite material.

Self-heating users are higher demand for heating, and the demand for maximum savings, self-heating is self-burning, when the temperature reaches a certain time, the heating will not burn, the wall thickness of the copper-aluminum composite radiator is thin, the heat dissipation is fast, relatively energy-saving, good corrosion resistance. Compared to the old saying of the community that gathers heating, it is recommended that you choose steel heating. >>>More

7 answers2024-04-16

1) In order to facilitate the inspection and maintenance of the product, keep more than 200 300mm space on the left and right of the product, and more than 600mm space on the front of the product. >>>More

7 answers2024-04-16

The switch of the wall-hung boiler always jumps by itself because the electrical load is too large. >>>More