What should I do if the pulse smoke fog machine does not come out of the fog

Updated on military 2024-04-13
8 answers
  1. Anonymous users2024-02-07

    The pulse smoke mist machine does not fog, most of which is due to the blockage of the nozzle or the problem of the secret closure of the fog.

    Cause. 1. The nozzle of the fog machine is blocked.

    The key channel through which the mist machine can spray fog is the nozzle of the spray bottle. Moreover, the nozzle of the mist machine is composed of a plurality of extremely small holes, if the liquid in the mist machine contains a certain amount of solid particles, in the process of spraying the mist machine, these solid particles will inevitably be blocked at the nozzle of the mist machine. This directly causes the occurrence of the phenomenon that the fog machine cannot spray fog.

    Solution 1: Open the spray bottle and clean the nozzle of the spray bottle to make the small hole of the nozzle of the spray bottle unblocked.

    Reason 2: There is a problem with the airtightness of the mist machine, resulting in the pressure in the bottle not meeting the spray requirements.

    The reason why the mist machine can spray is because a high-pressure system is formed in the mist machine, and the high internal pressure makes the liquid in the bottle spray out in the form of a mist. The key to ensuring that a high-pressure system can be formed inside the fog machine is the airtightness of the fog machine. If there is a problem with the tightness of the mist machine, the pressure inside the bottle will be the same as the outside, and then the phenomenon of no spray will occur.

    Solution 2: Open the fog machine, check the fog body and gasket and other components, and replace the damaged device. Under normal circumstances, the reason for the poor sealing of the fog is that the gasket is damaged, and the body will not be damaged.

    Working principle of pulse smoke fog machine:

    When the mist machine is working, the high-temperature and high-pressure airflow generated by the pulse engine (60 times per second) is sprayed out at high speed from the outlet of the nozzle, after opening the medicine valve, the air pressure in the medicine box (the engine medicine box is inflated 60 times per second to form air pressure) will hydrate the medicine into the burst tube, mix it with the high-temperature and high-speed airflow, at the moment of encounter, the liquid medicine is crushed into micron particles within 1 60 seconds and discharged into the air to cool to form a mist (smoke) high-speed spray from the nozzle, and quickly diffuse and diffuse, When the object to be controlled comes into contact with this fog or smoke, it plays a role in prevention or treatment.

  2. Anonymous users2024-02-06

    Carburetor problem, to replace it with a new one, look for Huayu intelligent fog machine accessories.

  3. Anonymous users2024-02-05

    There are two main problems with the pulse smoke fogging machine.

    The outlet of the carrier for making smoke is blocked, or the flow rate is too large or too small.

    The temperature did not reach the rated temperature.

  4. Anonymous users2024-02-04

    This should be repaired with a little better e-liquid.

  5. Anonymous users2024-02-03

    The person riding a horse is not necessarily Tang Seng, but it may also be a patrol officer.

  6. Anonymous users2024-02-02

    1.Inspect the carburetor diaphragm for damage and replace it if it is damaged. 2.

    Check whether the one-way throttle valve of the oil circuit is leaking, cracking or impurities entering, and the one-way throttle valve should be replaced or removed for cleaning in the above situations. 3.If you can't avoid the ignition or insufficient power after checking all of the above, please adjust the throttle appropriately.

  7. Anonymous users2024-02-01

    There are mainly the following two face-to-face problem reasons, one is to improve the gasoline marking information is not enough, can not meet the design requirements of the explosive power, when the liquid and the spray of the liquid contact, the instant gas generated will turn off the recoil of the machine, to replace the 93 or more standard gasoline, the second is through the nozzle and the combustion chamber tube carbon deposits caused by different exhaust pin keys are not smooth so that the machine automatically turns off, Because we have a part of the powder adhered to the inner wall of the nozzle when we spray the powder, which affects the narrow pipeline and can also make the national machine go out, we must use the development of a supporting wire brush to clean up the environment.

  8. Anonymous users2024-01-31

    Summary. Difficult to start 1: Pressing the oil bubble too many times or shutting down the machine in the wrong order causes gasoline and potion to remain inside the machine.

    Exclusion method: Before the machine is used, after adding gasoline to the mist machine sprayer, pay attention to the use of gasoline with No. 92 or above oil number, the better the quality of gasoline, the smoother the operation of the machine, press the gasoline in the two oil bubbles to about 2 3, after completion, tilt the mist machine outlet to the ground to see if there is gasoline or excess liquid flowing out, if there is a clean flow, and then try to restart. If the machine still does not start, please refer to Reason 2 for difficulty starting.

    Please note that as long as both bubbles have oil, do not press the bubbles at the same time in the future].

    What should I do if the fog machine can't start?

    Hello, happy to answer for you! 

    Difficult to start 1: Pressing the oil bubble too many times or shutting down the machine in the wrong order causes gasoline and potion to remain inside the machine. Exclusion Method:

    Before the machine is used, after adding the number of gasoline to the mist machine, pay attention to the use of gasoline of No. 92 or above, the better the quality of gasoline, the smoother the operation of the machine, press the gasoline in the two oils which Bi Jian Li brews to about 2 3, after the completion of the fog machine outlet to the ground, to see if there is gasoline or excess liquid flowing out, if there is a clean flow, and then try to restart. If the machine still does not start, please refer to Reason 2 for difficulty starting. Please note that as long as both bubbles have oil, do not press the bubbles at the same time in the future].

Related questions
14 answers2024-04-13

If you are using a Huawei phone and there is no sound when the phone is played, you can use the following methods to troubleshoot the problem: >>>More

16 answers2024-04-13

Brother, there is nothing that cannot be passed, and time is the best healing medicine. When you're in a bad mood, find a few good brothers, have some wine and chat, and when you're unhappy, find someone to talk to, and you'll be in a better mood. After a while, things will pass.

11 answers2024-04-13

There are many reasons why stool cannot be pulled out, mainly because modern people's diet is too fine, resulting in insufficient dietary fiber intake, which leads to various constipation problems such as not being able to pull out stool. At this time, it is recommended to supplement dietary fiber and active enzyme rich in Changla fruit enzymes, which is particularly good for improving stool, which is rich in dietary fiber, promotes intestinal peristalsis digestion, and softens and discharges the accumulated stool in the intestines, the effect is quite obvious, and there are active enzymes to repair the intestines, which is also very good for restoring normal bowel movements.

9 answers2024-04-13

There are many reasons for the information to be released, first of all, you can start the phone again to see if it is back to normal, whether the sending function is blocked, and it is blacklisted.

12 answers2024-04-13

When it rains, it is easy to fog up the windows when driving, and the front windshield is fogged together, which affects the driver's vision, and if it is serious, you may not be able to see anything clearly, which is very dangerous. So is there a better solution to the problem of fogging up the windows? >>>More