How many meters is the distance between the tailings pond and the house

Updated on society 2024-04-01
10 answers
  1. Anonymous users2024-02-07

    Case Status: What is the Termination of Unpaid Annual Fees [Economic Law] What is the distance between the tailings pond and the house [Property Law].Fast already. 1, 1 hour ago. The retirement age is based on the file or the ID card.

  2. Anonymous users2024-02-06

    We live under the large tailings pond above the head of Hengsheng Mining in Kuancheng County, Chengde, which is only 100 meters away from our residential area, and the house and concentrator are within the impact range of the downstream of the tailings pond.

  3. Anonymous users2024-02-05

    This is the groundwater polluted by the tailings pond, which has caused the well water in the villagers' homes to seriously exceed the standard, and we dare not drink it Because the underground mining area is very close to the villagers' houses, some of the villagers' houses are underground.

  4. Anonymous users2024-02-04

    How many meters should be the closest distance between the gold mine tailings pond and the residential area.

    1. Debris flows, washed away 10,000 acres of farmland, 2,961 houses, 429 reservoirs, ponds and dams, and 195 bridges and culverts; Twenty-nine people died, and the losses were terrible.

  5. Anonymous users2024-02-03

    The tailings pond is safe for how many meters from the house.

  6. Anonymous users2024-02-02

    Summary. The safety distance between two open pit mines is the blasting safety distance.

    The safety distance between the underground mine and the open-pit mine mining range should be calculated by a special intermediary research institution, and calculated according to the underground roadway, stope and mining area of the underground mine combined with the underground position of the open-pit mine and the mining mode of the open-pit mine.

    I have not heard of any requirements for the distance between the tailings pond and the mine, and according to the geographical location and environmental impact, the tailings pond will be specially designed in the general mine design.

    The safety distance between the tailings pond and the mine.

    Recently, the National Safety Committee has documented that the minimum safety distance between adjacent open-pit mine mining areas is less than 300 meters.

    The safety distance between two open pit mines is the blasting safety distance. The safety distance between the underground mine and the open-pit mine mining range should be calculated by a special intermediary research institution, and calculated according to the underground roadway, stope and mining area of the underground mine combined with the underground position of the open-pit mine and the mining mode of the open-pit mine. I have not heard of any requirements for the distance between the tailings pond and the mine, and according to the geographical location and environmental impact, the tailings pond will be specially designed in the general mine design.

  7. Anonymous users2024-02-01

    Summary. However, it is strictly forbidden to take soil and dig indiscriminately on the dam surface. The scope of soil extraction takes into account the specific local topographic conditions and the difficulty of the project. In addition, the soil extraction should not affect the stability of the dam body, the stability of the monitoring facilities and auxiliary works, such as the permeability hole.

    How many meters around the tailings pond can no soil be taken? Urgent!

    However, it is strictly forbidden to take soil and dig indiscriminately on the dam surface. The scope of soil loss and disturbance takes into account the local topographic conditions and the difficulty of the project. In addition, the soil extraction should not affect the stability of the dam answering body, the stability of the monitoring facilities and auxiliary works, such as the drainage holes.

    There are no clear provisions on the safety technical regulations of tailings ponds on how many stalls around the tailings pond can not be taken within meters, but it is strictly forbidden to dig soil on the dam surface if it is strictly forbidden to do so. The scope of soil extraction takes into account the specific local terrain conditions and the difficulty of the project.

    No specific values were found.

    But I think it's dangerous if it's less than 10 meters.

    3km is not a hard rule, generally will not choose the village Danqi upstream to build tailings pond, non-major industrial facilities, 500 or more, if there is a drinking wheel bright water source mold tung if you need to be 1km upstream, there are facilities or villages downstream, in the design of the dam failure calculation, to ensure that the dam collapse range above the range. Otherwise, you have to relocate.

    This is the distance from the village from the tailings.

    That is, if you take soil, you should choose to be 500 meters away, which is relatively safe.

  8. Anonymous users2024-01-31

    The specific distance is really not available, however, about the tailings pond, the following eighth article gives some answers.

    1. When selecting the site, there should be complete information on topography, engineering geology, hydrogeology, meteorology and other aspects.

    2. The site should avoid undesirable geological sections such as Kajite, quicksand, silt, collapsible loess, faults, landslides, debris flows, landslides, etc. Otherwise, reliable security measures must be taken.

    3. The allowable bearing capacity of the foundation of the general building and structure of the concentrator plant should be greater than; The allowable bearing capacity of the foundation soil of the main buildings and structures should be greater than.

    4. The site should not be selected in the area of seismic faults and basic cracks higher than 9 degrees.

    5. The site should avoid flooding and should be higher than the local calculated water level.

    6. The plant site shall not be arranged in the open-air blasting danger area of the underground goaf collapse boundary.

    7. The factory site should be located in the upwind side of the perennial minimum wind frequency direction in the residential area, and should avoid mutual pollution with other business units.

    8. The tailings pond should be located away from the densely populated place.

    Therefore, the establishment of tailings ponds should be far away from factories and residential areas, and at the same time, there should be staff to strengthen the patrol and management of tailings ponds to avoid accidents. At least 300m.

  9. Anonymous users2024-01-30

    1. According to the stacking method of tailings, the types of tailings ponds are divided into upstream type, middle line type and downstream type.

    For the middle line type and downstream type, the height of the tailings pond is the height difference between the dam crest and the dam bottom at the dam axis.

    For the upstream type, it is the height difference between the top of the stacked dam and the bottom of the dam at the axis of the initial dam.

    Note: 1The crest of the accumulation dam is the top of the sedimentary beach, and should not include the retaining sub-dam at the top of the beach that is higher than the beach surface.

    2.The bottom of the dam at the axis of the initial dam is not the bottom of the dam at the foot of the initial dam, and the two cannot be confused!

    Second, the tailings dam is composed of an initial dam and an accumulation dam. When the accumulation height of the tailings pond has not exceeded the initial dam, at this time, the accumulation height of the tailings pond is the height of the initial dam. That is, the height difference between the initial dam crest and the dam bottom at the dam axis.

    For details, please refer to the Technical Regulations for the Safety of Tailings Ponds (AQ2006-2005).

  10. Anonymous users2024-01-29

    This should refer to the design code of the mineral, and it is recommended to take a look.

    Code for Design of Tailings Facilities in Concentrators (ZBJ1 90).

    Regulations for the construction and acceptance of tailings facilities (YS5418 95).

Related questions
7 answers2024-04-01

According to the building design fire code.

GB 50053-94), technical specification for the design of high-voltage distribution devices (GB50062-92): >>>More

11 answers2024-04-01

In addition to projection,The reasonable **distance of various other TVs is about 4 times the size of the color TV。 For example, if it is a 20-inch (cm) TV, the distance is best 4 times that of 20 inches, that is, a little more than 2 meters away from the TV screen. For example, for a 21-inch color TV, the best** distance is meters; 29-inch color TV,**The distance is the best meter。 >>>More

8 answers2024-04-01

Jupiter's orbital radius is about.

Kilometer. The radius of the Earth's orbit is about. >>>More

10 answers2024-04-01

The gauge of the railway.

It refers to the shortest distance 16mm below the top surface of the inner rail of the two rail heads on the track. The gauge used by countries in the world is different, China uses the international standard gauge of 1435mm, greater than 1435mm for broad gauge, Russia is using broad gauge, and Vietnam uses less than 1435mm narrow gauge. >>>More

6 answers2024-04-01

The Earth's orbit around the Sun is not circular, but elliptical, so it produces perihelion and aphelion, which are taken as the average distance of 150 million kilometers Astronomical means that the average distance of the Earth from the Sun is about 150 million kilometers, and if the eccentricity is equal to zero, it represents a circular orbit (e = 0). >>>More