How to choose the location of 800kw diesel generator installation?

Updated on Car 2024-05-04
7 answers
  1. Anonymous users2024-02-09

    Choosing a good place to install an 800kw diesel generator is the most important of all the steps of installation, and the following factors are very important for site selection.

    1. Adequate ventilation.

    2. It can protect parts from rain, snow, hail, flood, direct sunlight, and overheating at freezing temperature.

    3. Do not expose the machine to polluted air, such as dust, fiber shavings, smoke, oil smoke, evaporation gas, acid, alkali, corrosive gas, smoke emitted by the engine or other pollution.

    4. Assemble the generator in a place where it will not be overwhelmed by fallen trees or electric poles, or where objects fall due to vehicles and cranes.

    5. There should be space around the 800kw diesel generator, one is for cooling, the other is for easy maintenance, at least 1 meter around, and there can be no other objects 2 meters above it.

    6. There should be a passage that allows the whole machine to pass through to the installation room. The air inlet and outlet pipes should be easy to load and unload so that they can be used as handling ports.

    7. Restrict non-management personnel from entering the computer room.

    If the generator must be assembled outside the building, it needs to be equipped with an all-weather enclosure or a container type. It is very useful for enclosure installations such as generator sets that need to be temporarily installed inside or outside the building.

  2. Anonymous users2024-02-08

    Don't be so troublesome, either build a computer room, or order a silent speaker directly from the manufacturer. It not only reduces noise, but also plays a protective role such as waterproofing. You can go directly to the manufacturer, and most manufacturers will make a plan for you.

  3. Anonymous users2024-02-07

    It is mainly composed of diesel engine and generator, and there are other accessories (battery, fuel tank) Make a bracket (girder) to fix the two, pay attention to the height of both! The rotor of the generator must be concentrically parallel to the crankshaft of the diesel engine! You can choose whether to install the clutch, and it is recommended that you buy a separator box if you install it, and you can go straight through without installation!

    Diesel generator is a kind of small power generation equipment, which refers to the power machinery that uses diesel as fuel and diesel engine as the prime mover to drive the generator to generate electricity. The whole unit is generally composed of diesel engine, generator, control box, fuel tank, starting and control battery, protection device, emergency cabinet and other components.

    It can be used for all kinds of homes, offices, large, medium and small enterprises for daily power generation and emergency power generation.

    A generator is a mechanical device that converts other forms of energy into electricity.

    A diesel generator is a combination of a diesel engine with a generator (usually an alternator) to produce electrical energy. Diesel compression-ignition engines are typically designed to run on fuel, but there are some types that are suitable for other liquid fuels or natural gas.

  4. Anonymous users2024-02-06

    There are many brands of generator sets, such as Yanan diesel generator sets, with stable performance and low fuel consumption, which are used in public utilities, education, electronic technology, engineering construction, industrial and mining enterprises, animal husbandry, communications, biogas engineering, and other industries. Different industries and different jobs require different generator sets in terms of power and performance. Therefore, the brand of the unit selected by the user is also different.

    There are many standard configurations of diesel generator sets, the common ones are:

    1. Suitable for the environment 40 50 lift Xunsou radiator water tank, belt driven cooling fan, fan safety cover;

    2. Direct injection internal combustion engine (diesel);

    3. AC synchronous generator (single bearing);

    4. Power generation output air switch, standard control screen;

    5. The steel common calendar base of the unit (including: the vibration damping rubber pad of the unit);

    6. Dry air filter, fuel filter, lubricating oil filter, starting motor, and self-charging generator;

    7. Starting the battery and the battery starting connection cable;

    8. Industrial 9db silencer and standard parts for connection.

    9. Random data: diesel engine and generator original technical documents, generator set manuals, test reports, etc.

    Note: The optional configuration cost of diesel generator set is charged separately, and the appropriate configuration should be selected for the unit according to the work needs!

  5. Anonymous users2024-02-05

    There are many configurations of diesel generators, there are standard configurations, there are optional configurations (additional billing), the configuration of the generator should be selected according to the working needs, working environment and working conditions of the unit.

    Such as anti-condensation heater, split daily fuel tank, integrated base fuel tank, battery float charger, rainproof unit (cabinet), self-protection, self-starting unit control screen, silent unit (cabinet), unit control screen with "three remote" function, mobile trailer power station (cabinet trailer), ATS automatic load conversion screen, silent mobile power station (cabinet trailer) and so on.

    There are so many optional configurations for the unit, and it is impossible to choose them all. When the unit or code needs to be easy to move, choose the mobile trailer configuration, when the unit needs sound insulation, choose the silent box configuration, and choose the four protection if the unit needs the protection function, etc., so that the diesel generator shirt orange which group chooses the compatibility bright set to meet the work requirements!

  6. Anonymous users2024-02-04

    Hello dear! We are glad to answer your question for cavity leakage: how to install and connect 200kw diesel generator set? A: Hello kiss<>

    First of all, the neutral wire is the live part, and the ground wire is the uncharged part; If the neutral wire is connected to the ground wire, it will only burn the neutral wire (or ground wire) directly. Second, the neutral line is the zero potential point on the generator, not the zero potential point; Its zero potential is based on the other three phases of the generator; If the three-phase winding is unbalanced, or the three-phase load distribution is different, this zero potential of the zero line will drift, that is, it will not become a zero potential; The point connected to the ground wire is always a zero potential point, not necessarily a zero potential point. The third thing to note is that three-phase generators are generally connected to a Y-shape, and compared with the triangular connection, it is impossible to form a circulation in the winding; And to connect the neutral wires, the main consideration is the output of the single phase.

    Fourth, if a three-phase generator has both a neutral wire and a ground wire, then this generator is a three-phase lead-infiltrated five-wire generator. Three-phase generators with neutral wire but no ground wire, or ground wire but no neutral wire are three-phase four-wire generators, thank you for your patience. The above is all the replies that I shouted rotten, if you are satisfied with my service, please give a thumbs up, and I wish you all the best!

    Peace and joy!

  7. Anonymous users2024-02-03

    1. The installation site should be well ventilated, there should be enough air inlet at the generator end, and there should be a good air outlet at the diesel engine end. The area of the air outlet should be more than multiple times the area of the water tank.

    2. The surroundings of the installation site should be kept clean, and items that can produce acidic, alkaline and other corrosive gases and vapors should be avoided nearby. If conditions permit, fire extinguishing devices should be configured.

    3. For indoor use, the smoke exhaust pipe must be channeled outdoors, the pipe diameter must be the diameter of the smoke outlet pipe of the silencer, and the elbow of the connected pipeline should not exceed 3 to ensure the smooth flow of smoke exhaust, and the pipe should be tilted down 5-10 degrees to avoid rainwater injection; If the exhaust pipe is installed vertically upward, a rain cover must be installed.

    4. When the foundation is made of concrete, the levelness must be measured with a level ruler during installation, so that the unit is fixed on the basis of the level. There should be a special anti-vibration pad or foot bolts between the unit and the foundation.

    5. The shell of the unit must have reliable protective grounding, and for the generator that needs to have a neutral point direct grounding, it must be neutrally grounded by professionals, and equipped with lightning protection devices, and it is strictly forbidden to use the grounding device of the mains power to carry out direct grounding at the neutral point.

    6. The two-way switch between the generator and the mains must be very reliable to prevent reverse power transmission. The wiring reliability of the bidirectional switch needs to be inspected and approved by the local power supply department.

Related questions
6 answers2024-05-04

Output common spare capacity (kva): 1000 1100 output common spare power (kw): 800 880Output common standby current (a): >>>More

11 answers2024-05-04

The 500kw of diesel generator should not be idle for a long time, which will reduce the quality of fuel injection atomization and accelerate the early wear of the cylinder wall of the diesel generator set. Because the quality of atomization is mainly directly related to the injection pressure, injector bore diameter and camshaft speed. Since the injector bore size is constant, the quality of the fuel atomization depends on the injection pressure and camshaft speed. >>>More

3 answers2024-05-04

There are many brands of 100kw silent diesel generators, including imported units, domestic units and joint venture units. Which industry is the purchase of diesel generator sets used in? Is it a common power supply or an emergency backup power supply? This is also a factor that influences the choice of unit brand! >>>More

7 answers2024-05-04

Treatment: Check and correct according to the wiring diagram. >>>More

6 answers2024-05-04

What are the things to pay attention to when buying a diesel generator? >>>More