What should I do if the noise of the newly bought Chigo air conditioner is so loud, 10

Updated on number 2024-05-16
16 answers
  1. Anonymous users2024-02-10

    Suggested approach:

    1. Find another air conditioner of similar size, compare and listen to the noise, in order to determine whether your air conditioner is really noisy and whether there are other abnormal sounds;

    2. Call Chigo after-sales service ** to complain, you can call many times;

    3. When after-sales personnel come to deal with it, whether it is handled well or not, they should clearly tell you the real reason for the noise.

  2. Anonymous users2024-02-09

    I bought a Supreme Air Conditioner and now want to return it.

    Do you know? The salary of a Supreme Air Conditioner salesman is twice that of a first-tier brand salesman.

    Any idea why?

    The salary after the sale is also twice that of other brands.

    Any idea why?

    Said very well, take it back and actually don't make heat, hit ** in the past, after-sales only said that I bought a small one, I just 10 square horses, the same area of 1 horse is done, he suggested that I put a cabinet machine in the bedroom.

    There is a noise in the air conditioner, he said it is normal, and it is normal to have a noise in the outside machine, I want to ask what is abnormal, is it not normal for the air conditioner to work normally?

    After the sale said that it would come immediately, I waited for three days, came twice, and left each time perfunctory, saying that I would go to another house, I was speechless.

  3. Anonymous users2024-02-08

    I bought the air conditioner on Double 11, I only started to use it last night, I don't need to know, I was shocked when I used it, and the foreign plane was like a bomber, and I didn't sleep all night.

  4. Anonymous users2024-02-07

    The first is the quality problem.

    Solution: 1. Find another air conditioner of similar size, compare and listen to the noise, in order to determine whether your air conditioner is really noisy and whether there are other abnormal sounds; 2. Call Zhigao after-sales service ** to complain and let the after-sales personnel come to deal with it.

    The second is the installation issue

    Causes and solutions:

    1. The reason for the noise of Chigo air conditioner - uneven placement.

    The bracket installation level of the external unit is unstable or the fixing screws of the combined bracket are not tightened and deformed, which will cause the uneven placement of the air conditioner outdoor unit, and the noise will occur during the operation of the air conditioning outdoor unit. Rearrange the bracket of the air conditioner unit, adjust the position of the air conditioner unit to ensure that it is placed horizontally, and tighten the screws of the air conditioner fixing bracket.

    2. The reason for the noise of Chigo air conditioner - air outlet noise.

    The greater the wind speed of the air conditioner, the greater the speed of the air conditioner's air outlet, and the corresponding expansion of its noise. When the indoor temperature reaches the set value, the wind speed of the air conditioner will be reduced accordingly, and the workload of the air conditioning tuyere operation will be reduced.

  5. Anonymous users2024-02-06

    When it comes to air conditioning, we must be familiar with it anymore, air conditioning is a very durable electrical appliance, it is easy not to have any problems, but there will also be problems, when there is a problem, we must find out what causes it, in order to prescribe the right medicine, today let's learn about the noise of the Chigo air conditioner.

    Product model: Chigo Air Conditioner KFR-35GW

    Reason 1The noise of the air conditioner may be due to the poor performance of the air conditioning compressor or aging, which will produce low-frequency vibration sound during the working process, which will also affect people's rest.

    Workaround:Adjust the compressor or replace the compressor for the air conditioner.

    Reason 2The greater the wind speed of the air conditioner, the greater the speed of the air conditioner's air outlet, and the corresponding expansion of its noise.

    Workaround:When the indoor temperature reaches the set value, the wind speed of the air conditioner will be reduced accordingly, and the workload of the air conditioning tuyere operation will be reduced.

    Reason threeThe reason for the high noise of the external unit of the air conditioner may also be the noise caused by the fan rubbing against the outer wall of the external unit during operation, or the noise caused by the friction between the external unit and the external unit fan due to excessive debris.

    Workaround:Adjust the distance between the fan and the outer wall of the air conditioner in time, if the air conditioner is stuck, add a little lubricating oil to the fan shaft to ensure that the fan rotates smoothly, and clean up the air conditioner in time if there is too much debris.

    If you can't handle it yourself, get a professional to have it inspected and repaired to avoid more damage.

    This article is based on the Chigo Air Conditioner KFR-35GW brand.

  6. Anonymous users2024-02-05

    Summary. Hello dear. <>

    The air conditioner may vibrate during operation, resulting in noise. Check that the air conditioner is securely installed, make sure it is in a stable position, and use rubber pads or anti-vibration pads to reduce vibration transmission. Fan Issues:

    The fan in the air conditioner may cause noise due to debris entering or damage to the parts. Check that the fan is working properly, remove any obstructions that prevent the fan from rotating, and make sure the fan blades are secure. <>

    What's going on with the loud sound of the air conditioner in the <>.

    Hello dear. <>

    The internal unit of the air conditioner may vibrate during operation, resulting in noise. Check that the air conditioner is securely installed, make sure it is in a stable position, and use rubber head-center pads or anti-vibration pads to reduce vibration transfer. Fan Issues:

    The fan in the air conditioner may cause noise due to debris entering or damage to the parts. Check that the fan is working properly, remove any obstructions that prevent the fan from rotating, and make sure the fan blades are secure. <>

    Hello dear. <>

    <> am honored to answer for you, thank you for your patience, and for you to inquire about the reason for Peihong: air duct problem: the air duct of the air conditioner may have air leakage or bad reputation, resulting in air flow through narrow or incorrect channels, resulting in noise.

    Check whether there is any looseness in the air duct connection, and close all the air ducts in the first and middle sections. Foreign Matter Ingress: Foreign objects such as dust and insects may enter the air conditioner and cause noise.

    Check whether there are foreign objects in the inner unit, and you can clean the inner unit with a vacuum cleaner or cleaning brush. <>

  7. Anonymous users2024-02-04

    Find the factory to send someone to check, they will help you, my home Chigo air conditioner, good.

  8. Anonymous users2024-02-03

    The first is that the machine is a quality problem, the second is an installation problem, and the third is an installation location problem, which can be checked and dealt with by professionals

  9. Anonymous users2024-02-02

    I only bought a Chigo air conditioner for less than 1 month, and the noise of the external unit is like an electric current. Hit ** to Suning. Here it is, and that's it. It is also said that the same goods as the air conditioner I bought are good and bad. Depressed. It seems that the next time you buy something, you will have to burn incense.

  10. Anonymous users2024-02-01

    It's possible, it's better to ask the manufacturer to get it.

  11. Anonymous users2024-01-31

    After the air conditioner is turned on, it is very loud, don't worry, you can see if it is the following reasons:

    1.When the air conditioner is started or stopped, it is normal for the plastic parts of the internal unit to make a sound due to the expansion and contraction of the internal unit due to temperature changes. There are also some pipelines that are deformed due to thermal expansion and contraction and are attached to the compressor or metal shell to cause resonance, so don't be too anxious at this time.

    2.Whether the fixed wall of the internal and external machine is strong, and the loose or deformed wall fixing screws are easy to lead to this situation.

    3.Check whether the indoor and outdoor connecting pipes are fixed and whether there is any collision with the outdoor unit or other objects.

    4.When the air conditioner is started or stopped, it is normal for the refrigerant in the system to make a loud flow sound before reaching equilibrium.

    5.If the outdoor unit is too dirty, clean it with water after the power is off.

    6.When the fan is running, it rubs against the outer wall, so adjust the distance between the fan and the outer wall in time. In addition, it is also possible that the fan is stuck, add some lubricating oil to the fan shaft of the air conditioner to ensure that the fan rotates smoothly.

    7.It is unlikely that the compressor gasket will resonate due to the aging of the gasket due to the stiffening of the gasket, or that the compressor itself will be noisy.

  12. Anonymous users2024-01-30

    Cause of failure: wall-mounted installation fixed wall-mounted wall panel is not firm and loose or the wall surface is uneven.

    Repair method: Re-fix the wall-hung panels, or treat the wall surface to keep the wall-mounted panels flat.

    Cause of failure: The wall-mounted indoor fan motor is not assembled in place with the through-flow wind wheel and fan bearing, which produces friction sound and causes the air conditioner indoor unit to be loud.

    Maintenance method: readjust the assembly position of indoor fan motor, cross-flow wind wheel and fan bearing.

    Cause of failure: Poor assembly of indoor fan motor and through-flow wind wheel.

    Maintenance method: Separate inspection and judgment. First of all, remove the cross-flow wind wheel to eliminate noise. That is, to replace the cross-flow wind wheel (the reason is mostly that the cross-flow wind wheel is unbalanced or deformed); Otherwise, the internal fan motor is faulty, and the internal fan motor is replaced.

    Cause of failure: The air flow is very loud.

    Maintenance method: a, first of all, judge clearly, just start a few minutes, the air flow sound is very loud, gradually and slowly reduce to normal, this phenomenon should be normal, to explain to the user that the phenomenon is just started, when the high and low pressure difference of the refrigeration system is not established normally, there will be a more obvious air flow sound, and then it will gradually become less normal.

    b. Improper installation causes the connecting pipe to bend and flatten and produce secondary throttling.

    c, the indoor unit evaporator interface welding slag plugging, replace the evaporator.

    Cause of failure: The air duct system is blocked.

    Maintenance method: clean the air duct system.

  13. Anonymous users2024-01-29

    It is caused by thermal expansion and cold contraction, and the evaporator of the internal machine should be lined with a rubber pad to avoid noise.

  14. Anonymous users2024-01-28

    It is not necessarily a problem with a rubber pad, I also have a Zhigao air conditioner, no case, it is recommended to contact the local after-sales service directly to see, anyway, you use their products to they get it until it is good.

  15. Anonymous users2024-01-27

    It is recommended not to do it yourself, find a professional to take a look.

  16. Anonymous users2024-01-26

    This problem is better for the after-sales service to take a look, there are many reasons for the problem, it may be dusty.

Related questions
14 answers2024-05-16

The air conditioner does not rotate at 17 degrees, and the 25 degrees does not rotate, and the outside unit rotates at 17 degrees, but the speed of its rotation is relatively slow, but you pay attention to it, because it does not rotate when he first starts refrigeration, and he will turn after a while, in fact, whether it is 17 degrees or 25 degrees, it is rotary.

6 answers2024-05-16

1.If the installation stability of the indoor unit is not good, when the outdoor unit of the air conditioner is running, the copper pipe is connected to the indoor unit. If the indoor unit is not stable enough, it will be affected by the compressor, resulting in the resonance of the indoor unit. >>>More

23 answers2024-05-16

The disassembly of the external unit of the air conditioner is to first compress the refrigerant**, use a tool to disassemble the connecting copper pipe and power cord with the internal unit, and then remove the fastening screws of the base and the support frame. >>>More

11 answers2024-05-16

When the ambient temperature is too high, the sun is direct and there is no shading object, the outdoor unit has poor ventilation and a mesh cover or the wall is blocked in front of the outdoor unit, the air conditioning heat cannot be blown out, and the temperature is too high, the compressor will automatically start the protection and stop working to avoid damage to the compressor. >>>More

4 answers2024-05-16

1. The voltage of the power supply is not enough.

Solution: Maintain a normal supply voltage. >>>More