How far is the air conditioning pipe from the wall, what is the distance between the pipes, and the

Updated on home 2024-05-16
4 answers
  1. Anonymous users2024-02-10

    National Building Standard Design Atlas 01K403 "Fan Coil Unit Installation", from the ceiling.

    Not less than 100 mm, generally selected at about 150 mm, there are no specific requirements from the wall, and can be carried out in accordance with the requirements of the ceiling.

    Key points of construction and installation:

    1.A filter should be installed at the water supply inlet of the unit. rinse in refrigerant.

    When the water system is main, the sewage is not allowed to pass through the coil. The highest point of the coil pipe should be provided with an exhaust device, and the lowest point should be provided with a water discharge device.

    2.Fan coil unit.

    The condensate discharge pipe must have a certain slope, and it should be ensured that there is no water accumulation in the drip tray.

    3.For the installation of the fan coil unit, please refer to the National Building Standard Design Atlas 01K403 "Fan Coil Unit Installation".

  2. Anonymous users2024-02-09

    The distance from the wall depends on the cooperation with other professions, such as whether there is a high-voltage trunking between the pipe and the wall, a fire pipe, a rain drainage system on the façade, etc., and it also depends on your own construction space and maintenance space. The spacing of the tubes is generally 50-150. As long as the installation position of the wind plate is reasonable, it doesn't matter.

  3. Anonymous users2024-02-08

    The water pipes of the air conditioning water system are generally not less than 200mm away from the wall, and the pipe spacing is generally 200mmBut it is not so rigid and can be appropriately floated according to the actual situation. The wind tray is generally arranged according to the building span, and the horizontal and cassette wind trays can be selected according to the shape of the room, the length and width of the wind tray (sometimes there are vertical and wall-mounted, but the use is relatively rare).

    The positioning size is also more flexible, based on the principle of reasonable airflow organization, no dead angles as much as possible, and convenient connection and balance of the water system. Among them, the horizontal concealed air tray is suitable for full ceiling and partial ceiling installation, and the full ceiling installation tuyere should be evenly arranged, and the local ceiling should pay attention to the air supply distance. The cassette wind tray is suitable for the installation of the full ceiling of the more square room, and the distance from the wall should not be less than 2 meters, and the spacing is 5 7 meters.

  4. Anonymous users2024-02-07

    The height is generally 230 left, depending on your family and your hobbies.

    Because of the back-out type, the copper pipe is envied in the lower right corner of the air conditioner.

    Mounted on the left side of a wall, the hole is 30-50 cm away from the corner. Mounted on the right side of a wall, at a distance of 100-120 cm from the corner.

    Be careful not to obscure the outlet.

    The position of the copper pipe is: the red dot position has been extended backwards, and the size of the air conditioner is appropriately enlarged, the size of different brands is different, basically the same, and the length and width are added by 150mm. Note: There can be no socket in the rectangular position of the entire back of the air conditioner.

Related questions
12 answers2024-05-16

It's not that inverter air conditioners are like this, and the two Midea inverter air conditioners in my room at home don't have this problem!! The air conditioner in my hometown was damaged a few days ago, and then someone replaced the pipe and added cold silence, and there was a sound when it was turned on, and the noise was quite loud! It's like a lonely and flowing voice in the tube! >>>More

10 answers2024-05-16

If only water enters the pipeline, the angle valve of the external unit is not opened, and the refrigerant is not discharged into the pipe. Then it's easier to deal with this way. Just use nitrogen to blow off the pipe, and then use a vacuum pump to vacuum to remove the water, the vacuum time is a little longer, and the water removal effect is better when the temperature of the pipeline is high. >>>More

13 answers2024-05-16

When you choose the toilet, you have to measure the size first, or it will be more troublesome to choose the installation at that time, you must know that you must measure its wall distance, these distances are determined when doing water and electricity. >>>More

9 answers2024-05-16

You can wash the air conditioning pipes in the auto repair shop, it is too troublesome to do it yourself, and it may not be clean. Including this oil circuit cleaning can actually be done without need, this oil sludge is mainly because of the poor quality of the oil, I used GT magic red maintenance has not been cleaned, after running more than 10,000 kilometers of replacement cycle engine is still very clean, usually the car runs without abnormal noise and shaking. Before, it was not possible to use the original engine oil, and the oil sludge produced by mineral oil was more, and the engine shook and made a large abnormal noise, and it basically had to be replaced in less than 5,000 kilometers.