Further judgment is as follows: 1. The flame-out needle must be combined with the solenoid valve, pulse igniter and other components, if it is only an independent flame-out needle, it is only a decoration. 2. If the gas stove disconnects the gas within 60 seconds, it means that the gas stove is protected by flame-out. Classification of flame-out protection devices for gas stoves Flame-out protection devices are mainly divided into:
There are two types: thermoelectric and ion-inductive. Thermoelectric: Safety factor.
High, even if a common fault occurs on one side, it will not interfere with the normal operation of the other burner. Ion induction: A common failure of one burner will result in the failure of all hobs.
The second is high power consumption, and the battery usually needs to be replaced once every 1-2 months.
Common sense of gas stove maintenance: be sure to open the window or exhaust fan to ensure the flow of indoor ventilation during the whole application process, if the gas stove is not used for a long time, the battery needs to be removed and the battery should be replaced regularly, and the flamethrower should be cleaned regularly with a soft brush or steel needle.
After cleaning, be sure to dry before installing, and the rubber hose should not be used for more than 18 months.
-
1.Check if there is a flame-out pin on the gas stove. There are usually two pointers on a gas stove, one is an ignition needle and the other is a flame-out needle. If there is only one ignition pin on the furnace, there is no flameout protection. You can't choose this one at the time of purchase.
2.Whether the gas stove can be automatically cut off within 60 seconds after it is turned off. The difference between having flame-out protection and not having flame-out protection is whether the gas can be automatically cut off.
3.When purchasing, you should check whether there is an induction probe on the burner, and there should be a flame-out protection device under the induction probe. When the flame is extinguished, the gas furnace is qualified if it can automatically cut off the gas within 60 seconds.
4.If the store doesn't provide an ignition, you'd better check it yourself after you get home. First, light the gas stove and then blow the fire out.
If you hear a "pop", it means that the automatic flame-out protection device has been activated and the valve has been closed. This is a qualified flame-out protection device.
-
The gas stove flameout protection is to close the gas channel when the gas stove is not working, or when the gas is accidentally turned off in the middle of the use process (the wind blows out, the soup is extinguished, and the ignition is unsuccessful), so as to avoid gas leakage accidents. Common gas stove flameout protection devices, mainly thermocouples.
flame-out protection device and self-priming valve flame-out protection device.
At present, there are basically two types of flame-out protection devices of gas stoves, one is to use thermocouples to generate electric potential by heating, through electromagnetic induction, so that the solenoid valve is in the state of opening the valve, if the thermocouple can not sense the flame, the solenoid valve is closed, so as to achieve the effect of flame-out protection; There is also the use of ion induction, through the pulser to control the closure of the solenoid valve, so as to achieve the purpose of flameout protection.
This answer applies to Fotile.
Most brands of gas stove models such as Vantage and Haier.
-
The flame out protection device of the gas stove is very simple, it can detect the flameout state of the gas stove in real time, when the flame of the gas stove is extinguished due to accident, the flameout protection device can cut off the gas source in time, avoid gas leakage, and avoid gas accidents.
The flame-out protection device is installed in **?
The flame-out protection device of the gas stove is installed in the burner head of the gas stove. There are generally two needles in the stove head of a gas stove, one is an ignition device used for ignition, and the other is a flame-out protection device.
Therefore, if you find that there is only one needle on the stove head of the gas stove when you buy a gas stove, it means that it must not have a flame-out protection device.
In addition, we can also test whether the gas stove has a flame-out protection device through the method of ignition test: light the stove, burn for 1 minute, adjust the flame to the minimum fire, artificially blow out the flame, you will hear the gas "Zizi" gas sound, and then start the timer, within 60 seconds the knob makes a "click" sound, indicating that the flame-out protection device has been activated, if there is no leakage, it proves that the flame-out safety device is effective.
-
Identify the gas stove used with automatic flame-out protection device:
1. Douse the gas stove with water, if the gas stove automatically cuts off the gas within 60 seconds, it is a qualified product. Otherwise, it is a substandard product.
2. Merchants confuse the concept of alarm device and automatic flame-out protection device, the main function of the alarm device is to test whether the gas is leaking, and the automatic flame-out protection device is to cut off the gas immediately after the gas leakage is found. Therefore, the simple alarm device can not effectively eliminate potential safety hazards, but only plays a warning role.
-
The reason may be that the ion induction extinguishing starts to extinguish the fire, and the current gas stove even has the OEM flame extinguishing protection. Because the state is mandatory. Generally, there are two types of flame-out protection.
1. Thermocouple extinguishing: using the physical properties of metal, it belongs to temperature difference induction, and the flame-out protection action is controlled by temperature induction. When the temperature is lower than a certain temperature, the air supply is immediately cut off, which is an immediate reaction, and the general extinguishing time is about 5 to 10 seconds.
2. Ion induction extinguishing: Using the photoelectric properties of the flame, when the flame deviates from the induction needle, it will immediately make a judgment in seconds and cut off the gas source within 5 to 8 seconds. The problem of poor circuit contact, which is easy to ignore, but often encountered in many old users, is mainly to check whether the positive and negative poles of the battery box are rusty, whether the line has poor contact, if there is, the rust needs to be removed, and the line is accurately connected.
Overvoltage protection, many gas stoves have overpressure protection function, once the overpressure is not started, then it is necessary to change a pressure reducing valve to try it, and the pipeline is blocked, which is a very common problem, once the pipeline is blocked, it is necessary to check the gas valve, generally speaking, you can smell the smell of coal and the gas stove is not on fire, it is likely to be gas blockage, and then it needs to be sparse. Or the micro switch is damaged, this is a very small place in the gas stove, but it is more difficult to repair than the usual fault, generally speaking, it is not recommended that the owner repair it himself, this is a fine, professional work, so please ask a specialist to solve. The last is that the ignition needle is dirty, the kitchen is a place that is easy to get dirty, it is easy to be contaminated with oil, etc., the gas stove is placed for too long, the ignition needle is easy to be stained by oil, then you need to clean the ignition needle of the grease, and then try to ignite.
-
Hello, gas stove flameout protection is when the gas stove flame is accidentally extinguished by wind, soup and other reasons, the flameout protection device will automatically turn off the gas source, so that there will be no gas leakage caused by the gas stove. Gas stoves refer to kitchen utensils that are heated by direct fire with gaseous fuels such as liquefied petroleum gas (liquid), artificial gas, and natural gas. Gas stoves, also known as stoves, are known to everyone about their popularity, but it is difficult to see a common concept.
-
"Gas stove flame-out protection" means that when the flame of the gas stove is extinguished by wind or soup, the gas stove will turn on the flame-out protection to prevent the gas from continuing to leak.
Precautions for the use of equipment: 1. Clean up the traces of the gas stove in time after use, and you can use a clean soft cloth to wipe the surface to avoid the accumulation of oil stains.
2. The equipment cannot be used, it may be caused by the gas running out, it needs to be recharged in time, it may be the hardware failure of the equipment, it is recommended to ask professionals to repair it; It may be that the ignition device is out of power and needs to replace the battery.
3. The equipment should be installed on a flat desktop to avoid affecting the use effect.
4. After the equipment is used, the valve should be closed in time to avoid gas leakage, and during daily use, professionals should be asked to regularly check the air tightness of the pipeline.
Be sure to choose a gas stove with stainless steel panels, and at the same time know the thickness of stainless steel, and the thicker the better. The burner must be made of pure copper, and only this material is the best. The higher the heat flow rate on the manual, the better, generally in between. >>>More
The reason why the gas stove does not ignite and the maintenance method. >>>More
There are five common reasons, the first is that the pulse igniter has no battery, the switch of the air source is not turned on or the air pressure is insufficient. The second is that the induction electrode in the ignition electrode is not far away or the top is contaminated. The air pressure is too high and the speed of the air flow is too fast, and it hits the spark. >>>More
The tempering of the gas stove, also known as "discharge", is the combustion phenomenon of the flame retracting into the inner cavity of the stove and the "deflagration" of the stove spray. >>>More
Teach you why the gas stove won't catch fire.