-
Installation standards and requirements for fire doors:
1. When installing the door leaf and door frame of the fire door, it is necessary to install it in accordance with the opening direction of the door, and the opening direction of the fire door must be the evacuation direction, and the distance between the door frame and the surrounding wall should not be too far, and rock wool can be filled if necessary.
2. When installing the wooden fire door, the door frame should be firmly fixed with the surrounding wall, the size of the door frame should be less than 20 mm of the opening, and the fixing points on both sides should be more than three.
3. When installing the steel fire door, the lower foot of the door frame needs to be buried in the ground for 20 mm, and then the embedded parts of the door frame and the wall.
Weld with a gap of less than eight millimetres between the door leaf and the door frame.
Precautions for installing fire doors.
1. Pay attention to the fire resistance limit, the fire resistance limit of each grade of the fire door is different, and the installation process should pay attention to whether the fire resistance limit of the fire door meets the design requirements, such as the design requirements of the Class A fire door.
However, Class B fire doors were installed.
or Class C fire door, the fire resistance limit does not meet the design requirements.
2. Pay attention to whether the middle seam and door crack are too large, the gap is too large during the installation process, easy to ventilate, smoke, and cannot achieve the role of fire prevention and smoke insulation.
3. Pay attention to whether it is necessary to install a door closer.
Fire doors are divided into normally closed fire doors and normally open fire doors.
Fire doors at the entrance of the passage and staircase need to be installed with a door closer, otherwise they do not meet the requirements of normal closure. Therefore, during the installation process, it is necessary to pay attention to whether the door closer needs to be installed, otherwise it does not meet the design requirements.
-
Fire door is a very important passive fire prevention measure in a building, which can protect people's lives and property in the event of a fire. The correct installation of fire doors can ensure that they are used to the fullest extent. The installation process of fire doors needs to be carried out in strict accordance with the relevant technical specifications and operating procedures.
Choosing the right fire door needs to consider factors such as the location of the building, its purpose, and relevant regulations. Buildings with different locations and uses have different requirements for fire doors, for example, in high-rise buildings, it is necessary to choose fire doors with a high fire rating, while in ordinary houses or shops, you can choose general fire doors. In addition, different regions also have corresponding fire protection standards, and fire doors that meet the standards should be selected according to local requirements.
Before installing fire doors, you need to prepare the necessary tools and materials, these tools include measuring tools, screwdrivers, electric drills, wrenches, etc., and the materials include expansion bolts, gaskets, sealants, etc. Preparing tools and materials helps to complete the installation process of fire doors smoothly.
Measuring the size of the door opening is an important step in installing a fire door. Measurements can be taken to determine the size and installation position of the door to ensure that the door will completely cover the door opening. The depth of the door opening also needs to be measured to determine if supports such as door frame reinforcement plates need to be added.
When installing a fire door, you need to install the door frame first. When installing the door frame, you should use expansion bolts and spacers to fix the door frame on the wall, adjust the horizontality and verticality of the door frame, and use tools such as a spirit level to check whether the leveling of the door frame is correct. If the door frame is not installed securely, it will affect the opening and closing performance of the door.
Inserting the door leaf into the door frame is the next step in installing a fire door. After inserting the door leaf into the door frame, adjust the position of the door leaf to ensure that the door leaf fits snugly against the door frame. If there is a gap between the door leaf and the door frame, it will affect the sealing performance of the door, and adding a sealing strip or gasket between the door leaf and the door frame can solve this problem.
Installing a door lock is the last step in installing a fire door. Reserve the keyhole position on the door leaf and use an electric drill to make a suitable keyhole on the door. Then install the lock cylinder and lock body to the door leaf and test whether the lock is functioning properly.
If the keyhole position is not suitable, you will need to re-punch the hole or replace the lock body.
Once a fire door is installed, it needs to be inspected and tested to ensure that the door can be opened and closed properly and that it can meet the corresponding fire rating requirements. At the same time, it is also necessary to check the sealing performance and fire performance of the door to ensure the use effect of the door. In daily use, regular maintenance and maintenance are also required, such as cleaning the door leaf, lubricating the lock cylinder and other operations.
-
Dear Kiss I am happy to answer for you, and my answer is as follows: The installation specifications and standards of the fire door are as follows: 1. When installing, the door frame should be buried 20mm below the elevation of the surface layer, and it shall not be less than the opening direction of the fire door must be the evacuation direction.
3. After installation, cement mortar must be poured between the door frame and the wall, and it can be used normally after curing for more than 24 hours. 4. Installation of fireproof glass: When the fireproof glass is installed, the seams on the four sides must be uniform, and the gaps on the four sides are filled with fireproof cotton after positioning, and then the edge banding strip is sealed.
5. The melting temperature of locks, hinges, bolts and other hardware accessories installed on the steel fire door shall not be lower than 950. 6. After the door leaf and the door frame are assembled, the door leaf and the door frame are attached in the normally closed state, and the gap between the door leaf and the door frame on both sides shall not be greater than 4mm, the gap on the upper side shall not be greater than 3mm, and the gap in the middle of the double door shall not be greater than 4mm.
-
In the process of designing and building buildings, there are very strict requirements for the safety of buildings, and fire doors are products that must be installed in the construction of buildings, because fire doors can provide escape channels for residents when a fire occurs, so what are the installation specifications of fire doors? Where do you need to install fire doors? Let's take a look!
1. What are the installation specifications for fire doors?
1. When installing the door leaf and door frame of the fire door, it is necessary to install it in accordance with the opening direction of the door, and the opening direction of the fire door must be the evacuation direction, and the distance between the door frame and the surrounding wall should not be too far, and rock wool can be filled if necessary. 2. When installing the wooden fire door, the door frame should be firmly fixed with the surrounding wall, the size of the door frame should be less than 20 mm of the opening, and the fixing points on both sides should be more than three. 3. When installing the steel fire door, the foot of the door frame needs to be buried in the ground for 20 mm, and then the embedded parts of the door frame and the wall are welded, and the gap between the door leaf and the door frame on both sides should be less than 8 mm.
2. Where do you need to install fire doors?
1. The fire front room needs to be installed with a water discharge door, and the fire front room refers to the stairwell, the elevator room and the evacuation channel between the place with smoke and fire prevention functions, according to the fire acceptance regulations, the stairwell or elevator room and the evacuation channel must be separated by a fire door, and the use of Class B fire door.
2. The door leading to the outdoor staircase needs to use a fire door, and the opening direction needs to be the evacuation direction, and the fire door in this place must also be a Class B fire door, as a fire door used in the outer staircase, not only to consider the fire resistance, but also to take into account the anti-theft property, so it is best to use a steel fire door.
3. In addition, fire doors need to be installed between the front room and the dredging passage, the stairwell and the front room, and the Class B fire door with a fire resistance limit time of one hour needs to be used, and the fire door between the elevator shaft and the machine room needs to use a Class A fire door with a fire resistance limit time of one and a half hours.
Summary: What are the relevant contents of the fire door installation specifications are introduced here, I hope to help friends in need. The fire door is not too expensive, so when you buy, don't pay too much attention to it, and choose a fire door with qualified quality, so as not to affect the normal use of the fire door.
-
A fire door is an important fire prevention facility used to stop the spread of fire and reduce fire losses. The installation standards and requirements of fire doors mainly include the following aspects:
Size and shape of fire doors: The size and shape of fire doors should be designed according to the requirements of standards and codes to ensure that fire doors can effectively block the spread of fire and smoke.
The material of the fire door: The material of the fire door should have good fire performance, such as steel, aluminum, wood, etc. At the same time, the surface of the fire door should be treated with anti-corrosion treatment to prevent wear and tear and damage to the fire door caused by long-term use.
Opening direction of fire door: The opening direction of fire door should be facing the direction of the safety exit to facilitate escape and rescue.
Where to install the fire door: The fire door should be installed on the firewall or in the location of the fire partition. At the same time, the fire door should match the wall, floor, etc. or royal decoration materials to ensure the overall beauty and coordination.
Tightness of fire doors: The tightness of fire doors should be tested and tested to ensure that fire doors are effective in preventing the spread of fire and smoke.
Quality and reliability of fire doors: The quality and reliability of fire doors should be tested and tested to ensure that fire doors can meet the specified requirements and standards.
In short, the installation standards and requirements of fire doors should be designed and constructed in accordance with relevant national norms and standards to ensure that fire doors can effectively block the spread of fire and smoke and protect people's lives and property safety.
-
The installation of doors is indispensable for the decoration of new houses, and many people will install security doors or fire doors considering the safety issues, but many owners do not know much about the installation standards of fire doors after buying fire doors, so what are the installation specifications and standards for fire doors? What should be paid attention to in the installation of fire doors? Let's take a look!
1. What are the specifications and standards for the installation of fire doors?
1. Before installing the fire door, the size of the opening should be determined, and the size of the opening shall not be less than the size of the door frame of the fire door; 2. After installing the fire door into the hole, it is necessary to adjust the surrounding gaps, and pay attention to whether the door frame and the fire door are fixed firmly; 3. Pour cement mortar around the door frame, so that less filling and more stirring, and do not move the fire door after watering.
2. What should be paid attention to in the installation of fire doors.
1. When installing the fire door, the appropriate installation method should be used according to the type of fire door, as for the door frame of the fire door, it is recommended that you use expansion bolts to fix, of course, you can also use the iron building in the process of building the wall, the iron building is embedded in the hole, and the hole needs to be welded firmly with the door frame connector during installation.
2. No matter which way is used to connect the door frame and the wall, the anchorage points on each side should not be less than three, and it is necessary to ensure that the concealment is firmly fixed. In the process of installing the fire door, the work of straightening and hanging should be completed first, and the correction and adjustment should be carried out to confirm that it is correct before proceeding to the next step.
3. If it is a sliding fire door, after installation, it is necessary to ensure that the sliding fire door is flexible, if it is a casement fire door, you should pay attention to whether it is convenient to open and whether it is tightly closed, etc., and at the same time, the door closer must be installed on the fire door, and the door opening needs to be installed with a sequencer.
Summary: What are the relevant contents of the fire door installation specifications and standards are introduced to you here, I believe you have a better understanding of the installation of fire doors. I hope to be able to help friends in need.
It is not only necessary to pay attention to the installation of fire doors, but also to choose a first-class fire door, so as to ensure the quality of fire doors.
-
The specifications and standards for fire door security inspection and ambush installation mainly include the following aspects: 1Material and specifications of the door:
The material of the fire door should meet the national standard, and the specification of the door should be selected according to the actual situation. 2.Installation of the door frame:
The door frame should be installed firmly, and the wall should be filled with fireproof materials to ensure the sealing of the ridge between the door frame and the wall. 3.Installation of the door leaf:
The door leaf should be installed on the door frame, and there should be a proper gap between the door leaf and the door frame to ensure the smooth opening and closing of the door leaf. 4.Tightness of the door:
The tightness of the door should be in line with the national standard, and there should be a proper gap between the door leaf and the door frame to ensure the tightness of the door. 5.Door Accessories:
The accessories of the door should meet the national standards, such as door locks, door handles, door hinges, etc. 6.Security Identification:
Fire doors should be marked with information such as fire rating, manufacturer, installation date, etc., so as to facilitate management and maintenance. 7.Installation Acceptance:
After the installation of the fire door is completed, acceptance should be carried out to ensure that the installation of the door complies with national standards and relevant regulations.
Fire doors can be consulted by Liandun Door Industry, Shanghai Liandun Door Industry **** is a professional enterprise specializing in the design, sales, installation and maintenance of metal doors and windows. The company's products cover a series of conventional products such as steel doors, steel fire doors, steel fire windows, steel roller shutter doors, steel fire shutter doors, stainless steel glass doors, stainless steel automatic doors, etc., and at the same time sell a series of innovative products such as steel fire and sound insulation doors, steel explosion-proof doors, steel explosion vent doors, steel airtight doors, steel large swing doors, steel large folding doors, steel large sliding doors and so on.
What brand of fire door is good? Become a problem that some procurement personnel need to face, with the modernization of social development, whether the building fire prevention facilities meet the requirements, has become a focus of the project completion testing standards, not only large new buildings must meet this requirement, some old-fashioned building renovation projects are also improving one by one, and as people ordinary small business places must also pass this pass, such as small hotels, restaurants, Internet cafes, nursing homes, cafes and so on; In order to give many people the opportunity to contact fire doors, so how to choose the right brand products? >>>More
Beima Fire Door Company, founded in 1990, is located in Huangcun Town, Daxing District, Beijing, covering an area of 23,000 square meters. For 26 years, we have focused on the R&D and production of fire door series products, and has the production qualification of GFM3030 Class A for super large fire doors. >>>More
The lap size of the door leaf and the door frame should not be less than 12mm; The door leaf has hinges with the door frame. >>>More
First, consider the strength of the manufacturer. High-quality fire door products are the best business card of manufacturers, but the manufacturers who choose to cooperate with Jianlong believe that it is not enough to only look at the product, and it is necessary to comprehensively consider the situation of the manufacturer to help cooperation. To put it simply, it is necessary to choose the most cost-effective fire door manufacturers to cooperate. >>>More