Equipped with Shuhu floor heating, so that you will not be stuffy at the same time, he uses graphene heating materials, the use of advanced technology, so that it produces heat at the same time, will not produce stuffy phenomenon.
-
The choice of carbon fiber electric floor heating, not only the choice of carbon fiber electric floor heating line brand, can determine the effect of carbon fiber electric floor heating, the most important thing is to see the quality of the insulation layer, and the design of the laying line is reasonable, and whether the construction is standardized, in order to choose a good product.
1. Requirements for heat source for carbon fiber electric floor heating:
Generally speaking, as long as it is a heat source that can provide enough hot water, such as wall-hung gas stoves, central heating, electric boilers, air source heat pumps, etc., can be used as a heat source for floor heating (plumbing), but the connection equipment is different.
If you want to use central heating as the heat source of carbon fiber electric floor heating, it is recommended to install a set of temperature control center device at the inlet, which mainly protects the 50-year life of the carbon fiber electric floor heating system and plays a role in cooling and energy saving. (Because to ensure the 50-year life of carbon fiber electric floor heating, the temperature of central heating water generally exceeds 60 degrees under the condition that the temperature does not exceed 60 degrees).
2. The impact of carbon fiber electric floor heating on floors.
The carbon fiber electric floor heating system needs to occupy about 5-6 cm floor height, which has a greater impact on the housing with low floor height. However, if you consider it in combination with the ground decoration, the impact is likely not to be large. For example, sometimes in order to bury water pipes and heating pipes under the floor, it is also necessary to add 4-6 cm of height to the floor structure layer, and this space can be used to install carbon fiber electric floor heating.
If you plan to lay a wooden floor, after installing a carbon fiber electric floor heating system, you need to play a keel on the wooden floor, and the floor can not be nailed, drilled, or drilled, so if you plan to install a wooden floor, it is not recommended to install carbon fiber electric floor heating. Floor tiles are preferred, followed by laminate flooring.
3.Should the geothermal floor be thin or thick?
What type of wood flooring is suitable for geothermal heating?
The two types that are more suitable for geothermal heating should be: laminate flooring and parquet. Geothermal flooring must have the "four" good requirements of good thermal conductivity, good thermal stability, good environmental protection performance and good deformation resistance.
Floor heat is transferred to the surface through the floor, and there is bound to be heat loss, which is minimized by an ideal floor. Therefore, in order to reduce the loss of heat energy and reduce the cost of heating operation and maintenance, the floor heating floor must be "thin but not thick". The thickness of the plate should be controlled within 12 mm.
-
First of all, you have to understand what the heating element of electric floor heating is, the electric heating film also has a name called temporary splicing heating equipment, the heating pad is an N-type separate heating element, and the leakage risk factor of the electric heating film is too high. The main comparisons are as follows:
1. There is no joint in the heating cable electric floor heating ground, and the electric heating film has two joints on average per square meter, a live wire and a zero wire, if you are a 100 house, there are about 40-45 more than 100 wire joints under the ground, and some of the current connected by the wire will be oxidized when it passes, and there will be poor contact and leakage and other dangers.
2. The electric heating film was originally designed to be used on the ceiling 10 years ago, and there was almost no underground installation, which was installed on the ground after processing by our domestic big coffee and cow b characters, why can't it be installed on the ground when electric floor heating is used, that is because the national electrical voltage construction code clearly requires that there are no joints in the concealed works with electricity. Of course, you can also ask an electrician how many joints are needed under the electric heating film floor.
3. Heating cable electric floor heating belongs to the category of high-power household appliances, so the requirements for safety are relatively high, the TV has a ground wire, the washing machine has a ground wire, the air conditioner has a ground wire, and the general household appliances will have a bottom line protection, the role is that in case of leakage, the current can be introduced into the earth through the ground wire, reducing the damage to the human body, but the electric heating film is too good x it has no ground wire, and people say that they don't need it.
4. The heating effect of the electric heating film is worse than that of the heating cable, because there is no way to lay the cement layer on the electric heating film, the professional scientific name is the heat storage layer, the function is that if the floor heating will first heat the ground, and then the cement layer will absorb the heat, store the heat and then dissipate it, even if there is no electricity, the ground is hot. The electric heating film is not unwilling to do the heat storage layer, but the essence of the electric heating film is very thin, and if the heat storage layer is laid, the electric heating film will be damaged.
5. As for the operating costs, they are all the same, because they are all electricity, how much electricity is given to where to put it, how many degrees you use, how much it costs, this is not who said whose materials are good, will save electricity than the other party, that is all nonsense. Hope it helps.
-
Due to the incomparable advantages in the installation of small-area floor heating, electric heating has incomparable advantages in terms of efficiency, use cost and after-sales maintenance, so many customers choose to install electric floor heating when installing floor heating. But what problems do we need to pay attention to when installing electric floor heating?
Carbon fiber underfloor heating wet paving (floor tile use).
1. The electricity load of the house.
1. If we install electric floor heating, it is not recommended to use high-power superwater heat in the home water heater, it is recommended to use an electric water heater with water tank heat storage, an energy-saving air energy water heater or a gas water heater. (The heating area is 75 square meters, and the floor area of the house is about 120 square meters or less).
2. It is recommended that if conditions permit, try to use dry paving, (the floor heating of dry paving can be laid directly on the floor, the heating is fast, the ground begins to heat up in 15 minutes, and the room temperature starts very quickly, and can be switched on and off at any time.) In this way, it can be switched on and off at any time according to the actual use requirements and according to the use time, and the electricity load is small. If floor tiles are used in the living room, then we recommend using at least dry paving technology in the bedroom.
Electric underfloor heating dry paving.
Carbon crystal floor heating dry paving.
3. The total air switch is 125 amperes, and the floor heating air switch is used independently, and the floor heating electricity and domestic electricity are used independently.
Second, the load of the line.
1. The main line of each group of floor heating must be at least 4 square millimeters, and the power of each group of floor heating shall not exceed 3500W.
2. The floor heating power cord cannot be used in parallel, let alone used on other domestic electricity.
3. District heating such as the living room and dining room needs to be divided into multiple groups to control to avoid excessive line load.
3. Stability of power supply circuits.
1. The power cord interface of the electric floor heating must be welded, and the weld joint must be smooth and flat.
2. The welding place of the power cord must be waterproof.
3. A separate junction box must be left at the wiring to facilitate later after-sales maintenance.
4. There is no connector in the middle of a single group of power cables.
Fourth, the configuration of floor heating power.
In the southern region, the recommended installation power of floor heating in the room with floor tiles is 150w square meters, and if it is dry, the power per square meter of floor heating should not be less than 120w square meters. How do you know if the installed power is sufficient? The cables are separated by 10 cm for 150W square meters, 12 cm apart for 120W square meters, and 15 cm for 100W square meters.
Fifth, temperature control size selection:
For electric heating temperature control, it is recommended to use a size of 25A, such as using 16A, the service life of temperature control will be shortened.
Of course, three points of materials, six points of construction, the above five points, just as our consumers in the installation of electric floor heating more basis, the real core role, or a floor heating company professionalism and rigor.
-
Warm city electric floor heating is installed by a professional master.
-
I'm in Yiwu, and I've installed graphene electric floor heating. My house is about 110 square meters, and when installing electric floor heating, you have to apply to the power supply bureau for expansion, and the power supply bureau will help you replace the three-wire (three live wires, one zero wire) meter with peak and valley electricity prices for free. Yiwu's power supply bureau is powerful, and it was replaced in three days.
-
No, as long as the wires connected from the distribution box are exceeded.
-
Like electric floor heating, after all, it is electricity, and there will be a certain amount of radiation, but the radiation to the human body is not large. If you are very concerned about the problem of radiation, it is recommended that you use water floor heating will be better, water heating, heating gas stove can solve the problem of domestic water at the same time, no need to buy a gas stove or electric water heater. Overall, let's compare more.
-
As long as the capacity is expanded, it is actually very simple to apply for electricity expansion, as long as the host of the real estate certificate applies to the local power supply bureau. The three-wire meter of an ordinary residential house is enough, the power of the ordinary meter is 8000W, and the three-wire meter is 24000W, which is definitely enough for you to use. And it can be replaced with a meter with peak and valley electricity prices at the same time, killing two birds with one stone!
-
If your house has been turned on natural gas, it is recommended to use a wall-hung boiler for water floor heating, if there is no natural gas, it is recommended to use an air source for water floor heating, because electric floor heating is relatively too energy-consuming, 100 square meters of electric floor heating, an hour to more than 10 kilowatt-hours of electricity, and you may not be able to afford the surface of the house, and the water floor heating due to the use of low temperature hot water heating, relatively high comfort.
-
It depends on how much area you actually install. Generally, the household inlet line is 10 square meters, the safe pavement area of electric floor heating is within 60 square meters, and more than 90 square meters must use three-phase electricity.
-
Since it is a new house decoration, you can choose water floor heating and radiator heating schemes. If it is a single aspect, small apartment area is recommended electric floor heating.
-
When you wiring, you have to discuss with the decoration master, calculate the total power of your own points, and then wiring, otherwise you will not wiring enough, and it is very easy to cause fire.
-
The floor heating company will help you think about it, you don't have to worry about this.
-
Generally will be more than after all, other places in the house also need electricity design margin.
-
How big you are, the average family wouldn't.
-
It is not recommended that you use electric underfloor heating! Other underfloor heating can be used.
-
The web link introduces the benefits of installing fresh air after installing floor heating.
-
The weather is getting colder and colder, and many homes in the north have installed underfloor heating. Some people feel that underfloor heating is warmer than heating.
62616964757a686964616fe4b893e5b19e31333431376631 and, and does not take up space, does not destroy the layout of the room. Therefore, installing underfloor heating at home is a good choice for cold areas. Which kind of floor heating is better to install?
Let's talk about it.
What do you need to install underfloor heating at home?
1. Determine the heating heat source first, if the heat source used for heating in your home is several heating heat sources, then if you want to install floor heating, it is recommended that you install a temperature control device at the floor heating connection, so that the life of the installed floor heating system is getting longer and longer, and at the same time it can also play a role in energy saving and cooling, because the long-term temperature is too high will reduce the service life of floor heating.
2. If the floor height of your house is not high, it is recommended not to use floor heating. Because the floor heating is installed on the ground, it is necessary to lay pipes and do insulation, so it will occupy part of the thickness.
3. After the floor heating is installed, because it is a lot of pipes installed and laid on the ground, it is not recommended to install the wooden floor when the ground is decorated, because if the wooden floor is laid, it is necessary to drill holes in the ground, and the floor heating has been installed, and on the ground, if the holes are drilled, the floor heating will be destroyed.
What kind of underfloor heating is good to install?
There are water floor heating and electric floor heating, and many people don't know which one is better. In fact, each has its own advantages and disadvantages.
Water floor heating: Generally speaking, the early installation cost of water floor heating is very high, and the maintenance of later problems is more troublesome, and the coil needs to be cleaned once every 2-3 years. However, it heats up smoothly, is suitable for the elderly and children, has a long lifespan, and can provide domestic hot water.
Water underfloor heating is suitable for areas with a heating area of more than 50 square meters, such as villas, townhouses, etc.
Electric underfloor heating: it does not provide domestic hot water, there is radiation;The circuit requirements at home are relatively large, and at the same time, it is not suitable for large-area installation. However, water underfloor heating does not require maintenance or cleaning, and the follow-up maintenance cost is also very low.
Electric underfloor heating is suitable for small and medium-sized apartments with a heating area of less than 50 square meters.
-
The heating method of electric floor heating is similar to the principle of an oven, the heating cable is buried under the floor, and the current is returned to the heating cable, which converts the electrical energy into heat energy, and the heat is transmitted to the floor and then to the room to heat up the room. Many times, homeowners also choose to install underfloor heating in rooms with cold floors, such as kitchens and bathrooms. When you wake up in the morning and everything is cold, the underfloor heating system will make you feel very comfortable.
Plumbing heats the water in the floor pipes, and then the hot water transfers the heat to the room, and the hot water will circulate under the floor, and the hot water will be continuously output through the boiler heating. Due to the large number of accessories in such a floor heating system, the installation is complicated, and it also increases the incidence of failure.
The boiler of plumbing will generally be replaced after ten years, and there will be more maintenance in the later stage, the thermostat is the same as electric heating, it will be broken after a few years, but the plumbing can also be used for domestic water, the advantages and disadvantages are everyone, it is recommended to use water heating if the area is large, and it is recommended to use electricity heating if it is small.
Generally speaking, there are three kinds - chemical soaking, projectile cleaning, and pulsed wave physical cleaning. Among them, the pulse cleaning method is the most used for floor heating, which can clean the scale and impurities of the floor heating pipe and water separator at one time. >>>More
When installing electric floor heating, it should be designed according to the actual situation, such as the insulation and heat dissipation of the room, or the function of the room, or the function of the room, of course, the placement of furniture should also be considered in the design of electric floor heating. After designing the installation plan of electric floor heating, it is necessary to lay the pipes of electric floor heating, when laying pipelines, we should pay attention to the quality of the pipes, and also pay attention to the quality of laying, because this will affect the effect of using electric floor heating. It should be noted that there should be a gap between the electric floor heating and the wall, so that the electric floor heating will not crack when heating. >>>More
As the world's most cutting-edge technology in the field of carbon fiber, Japan has a leading advantage in the development and production of carbon fiber technology, and the United States cannot compete with Japan in many aspects. Relying on the strong technical support of Shell Local Heating Japan Technology Center, Shell Local Heating focuses on the R&D and production of carbon fiber floor heating. In line with the concept of "paying attention to cutting-edge technology and arming products with science and technology", Shell Local Heating closely follows the world's most cutting-edge carbon fiber technology and draws on the new technology used in the field of global carbon fiber floor heating. >>>More
The whole process of electric floor heating system is based on electricity as energy, does not produce any harmful substances to the human body, and is recognized as a healthy and comfortable heating all over the world. As early as more than 30 years ago, Western countries fully used electric heating with heating cables as the heating element, and only Russia and China are still using traditional boiler heating in the world today. Coal heating is not only a waste of resources and not environmentally friendly, but also produces a lot of harmful gases, and electricity is a renewable energy source, which can be obtained by using hydropower, wind power, nuclear power and other means. >>>More
Floor heating thermostat has a week programming function, when the new product is first used, if you need to use a week of programming control, then you have to set the time parameters and temperature values of each period, generally a week of programming is divided into two cycles, respectively, "12345", "67" 5 + 2 programming mode, each day is divided into 6 periods, after setting a week of programming parameters, the thermostat will be controlled according to the parameters you set, if you do not need to use programming mode control, All you need to do is set the thermostat programming mode to manual mode (how to do it: press the mode button to change the working mode). >>>More