-
Guangzhou Beiyue Machinery] professional answer for you:
There are many reasons why you have to check step by step, and here are the reasons why the air compressor trips:
1.If the voltage is too low, it can be detected with a voltmeter.
2.Whether the transformer capacity is large enough, due to the use of air conditioners and electrical appliances in summer, the transformer capacity may be insufficient.
3.If the air compressor temperature is too high, it will also cause tripping.
4.Check the current of the main engine, generally the air compressor will have the main motor protection function.
5.The main engine does not run smoothly (caused by poor environmental maintenance or bearing problems) 6Check the lubricating oil level of the air compressor.
The above is the Beiyue mechanical engineer summarized several reasons why the air compressor tripped, our customer's problem is due to the voltage in their factory is too low, and then we suggested that he install a voltage regulator, and now the air compressor is running very stably! However, this kind of problem is best tested by air compressor professionals! In order to determine the specific cause, we will provide the most suitable solution!
-
Measure the actual current to see if it exceeds the rated value of the motor, if it exceeds the motor, it is the cause of the motor, or the load is too heavy. If it does not exceed the rated value, then the characteristics of the switch are not good or broken, and it can be replaced with a switch of the same model or a larger current model.
-
The air compressor tripped after a while, and the old electrician found the problem at noon.
-
There can be a variety of reasons why the old compressor protection switch trips.
1) First of all, it is necessary to determine whether the trip refers to the overload protector bouncing or the air switch in the power supply circuit bounceding. (2) If it is an empty opening, first determine how big the specifications of this empty opening are, judge whether it can bear the load of the machine, and convert whether it is overloaded as follows: 20A air opening, the machine power is 6KW, 6000W 220V=27A, the selected air opening is small, and you need to change to a large air switch.
3) If the specifications of the empty opening are sufficient, it may be a short circuit in the machine, and it is necessary to check the circuit of the machine to determine whether there is a short circuit. (4) Another possibility is the leakage of the machine, at present, some air open on the market is with leakage protection switch, such as the insulation layer of the live parts on the machine is damaged, it will lead to the leakage current will become larger, once the leakage current to the ground is greater than 30mA air open will jump open. It is necessary to use professional equipment to detect which electrical components are resistant to voltage, or replace them one by one to check and confirm.
If you want to know more about air compressors, it is recommended to consult Tianshui Jufeng. Tianshui Jufeng with strong technical force, advanced production technology, scientific testing methods, standardized management process, in the fierce market competition to achieve leapfrog development, pay close cooperation with international customers, in the dedicated service for every customer has won the trust and praise, the products sell well all over the country and Japan, the United States and other countries; At the same time, it is affordable, abundant, high quality, and fast delivery. [Click to learn more about the model rock drill**, the strength of the manufacturer fast delivery.
-
Summary. What is the cause of the air compressor trip problem? Hello dear, there may be the following reasons:
1.Because the starting current of the air compressor is relatively large, the setting current of the power switch is relatively small, and the starting current of the motor is not avoided; 2.The motor has faulty grounding or phase-to-phase fault short circuit; 3.
If the air compressor temperature is too high, it will also cause tripping. 4.The main engine does not run smoothly (caused by poor environment and poor maintenance or bearing problems); 5.Check the lubricating oil level of the air compressor.
Air compressor is the basic product of industrial modernization, and it is often said that electrical and automation has the meaning of full pneumatic; The air compressor is to provide air source power, is the core equipment of the pneumatic system electromechanical air source device in the main body, it is the original mover (usually the motor) of the mechanical energy into gas pressure energy of the device, is the compressed air pressure generation device. Hope it helps.
What is the cause of the air compressor trip problem?
Tripping on the way to work.
What is the cause of the air compressor trip problem? Hello dear, there may be reasons as follows:1
Because the starting current of the air compressor is relatively large, the setting current of the power switch is relatively small, and the starting current of the motor is not avoided; 2.The motor has faulty grounding or phase-to-phase fault short circuit; 3.If the air compressor temperature is too high, it will also cause tripping. 4.
The main engine does not run smoothly (caused by poor environment and poor maintenance or bearing problems); 5.Check the lubricating oil level of the air compressor. Air compressor is the basic product of industrial modernization, and it is often said that electrical and automation has the meaning of full pneumatic; The air compressor is to provide air source power, is the core equipment of the pneumatic system electromechanical air source device in the main body, it is the original mover (usually the motor) of the mechanical energy into gas pressure energy of the device, is the compressed air pressure generation device.
Oil-free. Hello dear, please follow the above description.
-
Hello, dear, what is the cause of the air compressor trip problem? 1.Because the starting current of the air compressor is relatively large, the setting current of the power switch is relatively small, and the starting current of the motor is not avoided; 2.
The motor has faulty grounding or phase-to-phase fault short circuit; 3.If the air compressor temperature is too high, it will also cause tripping. 4.The main engine does not run smoothly (caused by poor environment and poor maintenance or bearing problems); 5.
Check the lubricating oil level of the air compressor. Air compressor is the basic product of industrial modernization, and it is often said that electrical and automation has the meaning of full pneumatic; The air compressor is to provide air source power, is the core equipment of the pneumatic system electromechanical air source device in the main body, it is the original mover (usually the motor) of the mechanical energy into gas pressure energy of the device, is the compressed air pressure generation device.
-
1. The voltage of this line connected to the air compressor is not stable or the voltage is insufficient. For example, there are other devices connected to this lying line.
2. When the unit starts, the inlet valve is originally closed, but it is not closed, resulting in the air entering the main engine in advance and increasing the load at start-up. 3. The failure of the motor or the host itself, such as the damage of the bearing, can be manually rotated to try. 4. According to the landlord's question in this period, it can be considered that in winter, the decrease in ambient temperature will lead to the increase in the viscosity of the lubricating oil inside the unit, and the tripping phenomenon will occur when the unit is cold.
-
Summary. Hello, it is a pleasure to have your question, and according to the situation you have described, it is generally recommended that you refer to it at this time.
The first reason: because the heavy load exceeds the rated load, it is an overload protection trip. The second reason:
Because some electrical appliances have grounding phenomenon, tripping due to leakage protection You can gradually plug in or open the electrical appliances, when opening a certain electrical appliance tripping, you must first check whether this piece is suspected of leakage, or high-power electrical appliances, the load has accumulated to exceed the rated load. The third reason: check whether there is leakage can turn off or unplug other electrical appliances, open this piece separately, if it is turned on normally, it means that it does not leak, if it will also trip, it means that the problem is on this equipment.
I hope to help you and wish you a happy life
The air compressor protection switch is old tripped.
Hello, I'm glad to be able to ask you about your question, according to the situation you described, it is generally recommended that you refer to it at the moment The first reason: because the heavy load exceeds the rated load is an overload protection trip. The second reason:
Because some electrical appliances have grounding phenomenon, tripping due to leakage protection You can gradually plug in or open the electrical appliances, when opening a certain electrical appliance tripping, you must first check whether this piece is suspected of leakage, or high-power electrical appliances, the load has accumulated to exceed the rated load. The third reason: check whether there is leakage can turn off or unplug other electrical appliances, open this piece separately, if it is turned on normally, it means that it does not leak, if it will also trip, it means that the problem is on this equipment.
I hope to help you and wish you a happy life
Hello, I hope to help you, I wish you a happy life, and you can consult me if you have any questions
The current and voltage are normal, and there is no short circuit, jump the air switch.
Hello, that is to say, you have excluded the above situations, right?
Are you sure that your environment is not overloaded?
-
1.If the voltage is too low, it can be detected with a voltmeter.
2.The transformer capacity is judged to be large enough due to the use of air conditioners and electrical appliances in summer, which may lead to insufficient transformer capacity.
3.If the temperature of the air grinding press is too high, it will also cause tripping.
4.Check the current of the main engine, generally the air compressor will have the main motor protection function.
5.The main engine does not run smoothly (caused by poor environmental maintenance or bearing problems) 6Check the lubricating oil level of the air compressor.
Hope it helps!
Viltek-Beijing Changfeng Tiancheng Engineering Technology ****.
Radish and cabbage have their own love This depends on what you think of it Now there are too many air compressors on the market But there are few companies that really have the ability to produce air compressors There are only a few real brands Most of the rest are OEM or small factory assembly There is no ability to develop the most core components The main engine is purchased, the quality of an air compressor mainly depends on whether its gas production is sufficient, and whether the design of its internal components is reasonable, rather than whether it is cheap, and the price of a good machine will not be cheap. If you blindly value the price, then you are destined not to buy good equipment, I have been engaged in the air compressor industry for more than 10 years, all kinds of air compressors have been contacted, have been maintained, at present, there is no brand of ordinary screw air compressor in China can give Atlas Ingersoll Rand gas production and reasonable internal design, but their price can throw Atlas Ingersoll Rand several streets, so they can only use ** to determine the market. Therefore, at present, all domestic manufacturers are producing energy-saving air compressors, so as to improve the efficiency of air compressors, but the gap is always a gap Domestic air compressor manufacturers blindly kill the first day and do not pay attention to machine research and development, as far as I know, there are currently one or two air compressor manufacturers are investing heavily in the research and development of air compressor hosts, one is the giant wind in Guangdong
Domestic nose! **Lower!
It is suitable for private enterprise users with limited investment in air compressor equipment. >>>More
The difference between oiled air compressor and oil-free air compressor is: different materials, different final discharged gases, and different service life. First, the material is different 1, there is an oil air compressor: >>>More
There are two knobs on the pressure switch, one is the upper limit of pressure regulation, and the other is the lower limit of pressure regulation. The clockwise hand is addition, and the counterclockwise is subtraction. It is best to have a pressure gauge on the air compressor, so that you can know which button you adjust is the upper limit, which is the lower limit, and how much. >>>More
Caused by the compressor temperature being too high. or caused by poor lubrication of the compressor. >>>More