    Non-sunken toilets are off-floor drainage toilets. In principle, it is not possible to change some of the branch pipes in the room. However, when the next floor residents agree to allow the change, appropriate changes can be made.

    After the change, a irrigation test should be done. This is done by preparing more than 20 litres of water and pouring it from the toilet quickly at one time, so that whoever is in the toilet is close to full. Then check the next layer of modified pipes for leakage.

    Don't look at it, but use a paper towel to press the sassafras test at each interface, as long as the paper towel has no traces of yes, it is qualified

  2. Anonymous users2024-02-11

    Villa basement, townhouse basement, ground floor duplex and other room types, in the basement is lower than the outside, the domestic sewage and wastewater generated cannot be naturally discharged outside. So what should I do if the basement is lower than the outdoor and I want to make a bathroom? This is where a lift pump comes in.

    Generally speaking, the lifting pump solves the drainage problem, mainly through the centrifugal force generated by the high-speed operation of the motor to pressurize the sewage and discharge it into the main pipeline on the first floor, and discharge it outdoors with the sewage on the upper floor.

    The basement wants to be used as a bathroom, because the terrain is low, and a lifting pump is needed to solve the drainage, and the specific parameters need to be determined according to the drainage volume and lifting height. Different application scenarios, such as home toilets and public toilets, have different water consumption and need to match different models.

    Household toilet drainage, standard configuration of drainage sanitary ware including toilet, basin, shower, mop basin, etc., for these sanitary ware drainage needs, home toilet lifting pump will be equipped with 3-4 water inlets, including 110 (mainly connected to the toilet mouth 40 mouths (mainly connected to the basin, shower and other sewer).

    In the early stage of water and electricity, the home needs to reserve water and electricity, and the corresponding pipe diameter can be reserved according to 110 50, which can adapt to the water inlet reserved by most of the equipment.

    The situation of commercial public toilet drainage is much more complicated, you need to consider how many pits are set up, how many sinks are used, how many people will use them every day, estimate the approximate drainage volume per hour or day, and then determine the flow parameters of the lift pump.

    Taking the public toilet in the shopping mall as an example, the general LG floor has 1-3 floors, and you can choose to solve the drainage on each floor, or several floors can be gathered to the lowest floor, and then raised from the lowest floor to the ground floor.

    The basement is lower than the outdoor and wants to be used as a bathroom, and there are different solutions according to different usage scenarios, and the specific needs to be matched and selected according to the working conditions. Zhiliu intelligent sewage lifting pump, wifi networking, remote intelligent control and debugging, integrated leakage water monitoring, automatic backcleaning, solve the problem of basement toilet drainage without worries!

  3. Anonymous users2024-02-10

    Do the math how much it will cost you to renovate your home

    The bathroom is a very important part of the renovation, and the sewer pipe is the top priority of the bathroom. If the sewer pipe is not installed well, it is easy to cause pipe blockage and affect the later life. So can the bathroom sewer pipe be changed?

    Can the bathroom sewer pipe be changed.

    Whether the bathroom sewer pipe can be changed depends on the specific situation, if you live on the first floor, then you can change it. If you live on the second floor or above, you will need to negotiate with your neighbor upstairs. It is best not to change the sewer pipe in the bathroom, because it is not only related to the drainage of your own home, but also affects the drainage of users upstairs.

    What should be paid attention to in bathroom decoration.

    1. When decorating the bathroom, the waist flower and size of the tiles should be designed in advance, so that it is easy to calculate the number of tiles. In addition, the tile should be non-slip, the safety factor is relatively high, and the floor tile needs to be aligned with the wall joint when paving, so that it is more neat and beautiful. When using tile caulk, you can debug it first, so that you can know the approximate dosage.

    2. When decorating the bathroom, you should do a good job of waterproofing, the bathroom is the place where water is used most frequently, if the waterproofing is not done well, it will directly affect the future life. The ground and wall are an important part of waterproofing, the ground is not waterproof, there will be water leakage, and the wall is not waterproof, it is easy to mold. After the waterproofing is done, a closed water test is required, and the next step can only be carried out after the test is correct.

    3. When the bathroom is decorated, a shower room can be designed, so that the area can be divided. The shower room can be designed with a window to facilitate ventilation. In addition, the door boundary of the shower room can be designed to be a little higher, so that the water in the shower room can be prevented from overflowing.

    The glass of the shower room should be filmed, which can prevent the glass from breaking and is safer.

    Enter the area and get the decoration for free**].

  4. Anonymous users2024-02-09

    It can be changed, but the following points need to be considered:1Pipeline Location:

    Restroom sewer pipes are usually fixed, and it is important to consider whether the new plumbing can be connected to the existing sewer pipe. 2.Pipe Material:

    The toilet sewer pipe is usually PVC pipe or cast iron pipe, and it is necessary to choose the appropriate pipe material according to the actual situation. 3.Pipeline Construction:

    Altering the sewer pipe requires construction, and the impact of the construction on the use of the restroom, such as noise, dust, etc., needs to be considered. 4.Laws and Regulations:

    Alterations to sewer pipes need to comply with local laws and regulations, such as the need to apply for relevant building permits. Therefore, if you need to change the toilet sewer pipe, it is recommended to find a professional plumbing engineer for consultation and construction.

  5. Anonymous users2024-02-08

    OK. There are 2 ways to do this:

    1. Negotiate with the owner downstairs to change the original pipeline directly from downstairs. This method is not prone to clogging problems. 2. Raise the floor of the bathroom.

    The elevation of the floor is directly proportional to the drain in your toilet. If your room height is enough, you can choose this method, but this method may cause sewer blockage in the later stage, so you need to be cautious.

  6. Anonymous users2024-02-07

    If it is on the first floor, it can be changed, and if it is on the second floor including the second floor or above, it is necessary to consult with the neighbors.

    The bathroom of home decoration often encounters a troublesome problem, that is, the toilet drain of the bathroom is not very suitable, and the decoration design needs to be painstakingly conceived if it is renovated for the convenience of use. Four common ways to remodel your toilet drain teach you how to move your toilet drain pipe.

    Displacement of a small area:

    Use a special shifter for lifting, there is cm, it is recommended not to exceed 10cm shift, it will affect the effect of punching and draining.

    Wide range of displacement:

    Floor elevation (generally 20cm high), discharge pipes, pipes should have a certain slope, but the distance should not be too long, the distance is long, the slope of the pipeline should be larger, the ground elevation will increase, and the flushing effect will also be affected. The drain pipe can be connected to the original pothole, and can also be connected to the sewer main pipe with 3 passes.

  7. Anonymous users2024-02-06

    Key points of secondary drainage design of sunken toilet:

    1. Backfill height.

    Since the sinking height of the bathroom is generally above 400mm, when backfilling, you can use pebbles or ceramsite to backfill, and the backfill height is not less than 100mm and less than 150mm.

    For the bathroom is relatively large house, it is recommended to use red brick or concrete as a partition overhead to divide the caisson into a number of 400 * 400 or so grids, this step many people do not do, one is to save money, the other is to save labor, theoretically there is such a partition for a long time, the concrete above is not so easy to fall.

    2. Backfill material.

    Most of them are backfilled with ceramsite, and too much pebble backfill will increase the load on the bathroom. Ceramsite is light in weight, moisture absorption, easy to maintain, and other characteristics such as strong adsorption and dirt interception capacity, good physical, chemical and hydraulic properties are suitable filling materials for the specific environment of toilets. Remember not to backfill with river sand, stone powder, etc., so as not to block the drainage pipes.

  8. Anonymous users2024-02-05

    Now many family bathrooms are sunken toilets, sunken toilets have more benefits, and many owners also want to do secondary drainage in the sunken bathroom, so that even if there is a leakage, then through the secondary drainage, it can be discharged, to avoid letting the sinking layer become a waterlogged layer, so what should be done about the secondary drainage work of the sunken toilet?

    1. The conditions that should be met for secondary drainage in the sunken toilet.

    1. The height of the sinking layer should be deep enough.

    If the sinking layer is relatively low, there is no need to do secondary drainage, and it is not good to do secondary drainage.

    If you want to do secondary drainage, it is generally required that the depth of the sunken toilet is greater than 30 cm, so that it is convenient to do secondary drainage.

    2. The construction master has the ability to change the main sewer pipe.

    To do the secondary drainage of the sunken bathroom, then the master should have the ability to renovate the main sewer pipe. Therefore, the sunken toilet does secondary drainage, and there are certain requirements for the craftsmanship of the construction master.

    Second, the construction steps and precautions for secondary drainage of sunken toilets.

    1. Lay the pipe on the basis of not damaging the developer's original waterproof layer. If necessary, we can use bricks for support.

    2. At the same time of pipe routing, connect a floor drain on the 50 cross. This floor drain is used as a drain for secondary drainage.

    3. Cement leveling. At the same time, it is necessary to ensure that the floor drain of the secondary drainage is the lowest, and a slope should be made so that the stagnant water can be discharged smoothly.

    4. Make a layer of waterproofing, and then make a 40*40 lattice to support the floor level of the bathroom. It should be noted that the bottom of the lattice should be reserved for water and should not be blocked.

    5. Ceramsite backfill. Generally, the backfill of the toilet is made of ceramsite, which is light in weight and can ensure the smooth flow of stagnant water. Do not use construction waste to backfill, otherwise it will scratch the original water pipe.

    6. Frame steel bars, cement leveling, brush waterproof layer, and paste tiles. In order, the entire backfill of the bathroom is done.

    According to this step, the secondary drainage and backfill of the bathroom will be completed, and under normal circumstances, if the construction project is done well, there will be no water leakage; However, in the event of a water leak, the water in the sinking layer can also flow out through the mouth of the secondary drainage, so there is no need to worry about the accumulation of water in the waterproof layer.

  9. Anonymous users2024-02-04

    This drainage is too bad, and there are too many detours.

  10. Anonymous users2024-02-03

    1. Block the sewer pipe of the original buried bridge foundation, and the sealing must be good.

    2. Pry open the tiles in the bathroom and chisel a hole.

    3. Extend the liquid envy pipe into the hole and connect it to the sewer, which needs to be sealed to prevent water leakage.

    4. Pave the tiles in the bathroom and cover the hole. This ensures that there are no leaks in the pipes.

  11. Anonymous users2024-02-02

    Usually in order to facilitate the use of the bathroom by the family, the waterway will be modified before the decoration, today I want to share with you how to change the sewer toilet on the second floor alone and what are the precautions for changing the sewer pipeline, friends who want to know may wish to take a look at it!

    1. Second, how to change the toilet separately in the building.

    First plug the original sewer joint, then use a sewer pipe with a diameter of more than 40mm to connect a sewer, and install a U-bend anti-odor pipe under the toilet bowl. Because the sewer pipe of the sink and floor drain in the bathroom and kitchen is the same, in order to prevent the water from flowing back when the washing machine is used, it should be carefully arranged.

    2. What are the precautions for changing sewer pipes?

    1. When renovating the sewer pipeline, the glue at the interface must be cleaned up, and the inner circle and outer circle of the pipeline must be coated with glue, which is a very important process.

    2. All sewer pipes should be installed with exhaust outlets, and exhaust holes should be installed at the highest place, otherwise when it comes to summer, the residue in the sewer pipes will ferment, so that the indoor smell is stinky, and it is also very bad for people's health.

    3. Before installing the sewer pipe, it is necessary to grasp the slope of the pipe, usually the water inlet is higher than the water outlet.

    4. When installing the water pipe, the anti-odor elbow must be installed, and the residents downstairs must be negotiated in advance before the transformation.

    5. The installed sewer pipe should not be too long, otherwise it will produce unfavorable drainage, so it is easy to block.

    6. After the sewer is renovated, it is necessary to do sealing work to prevent the cement from accidentally getting on the sewer pipe during floor construction.

    Summary: The above is for you to share how to change the sewer toilet on the second floor alone and what are the precautions for changing the sewer pipe, I believe you also have a corresponding understanding after reading the above sharing, if you need to learn more about relevant information, please continue to pay attention to Qeeka Home**, will answer for you one by one.

  12. Anonymous users2024-02-01

    The sewer pipe is an important part of the bathroom decoration, if the bathroom sewer pipe is not installed well, it will bring a lot of trouble to our life, so when the bathroom is decorated, the installation of the sewer pipe must be done. How to change the toilet decoration? The following are the key points of the toilet sewer pipe construction instructions, I think it must be seen!

    1. After the installation of the water pipe, the pressurization test must be carried out: the pressurization test is generally carried out under the condition of double water pressure, and there should be no water leakage in the test.

    2. A simple test method without pressurization, but it is not completely feasible.

    1) Close the main valve of the water pipe. (i.e. the water pipe switch in front of the water meter).

    2) Turn on the faucets in the room for 20 minutes, making sure there is no more water and turn off all the faucets.

    3) Turn off the water inlet switch of equipment with water storage function, such as toilet tanks and washing machines.

    4) Open the main valve of the water pipe.

    5) 20 minutes after opening the main valve, check whether the water meter is moving, including slow walking. If there is movement, it is a water leak. If you don't move around, you'll probably be fine.

    If there is a problem with the water meter or the water pipe is slightly permeable, it may be difficult to determine. Therefore, it is recommended that the water pressure test experiment must be carried out after the construction, generally 8 kg, and the time is 20-30 minutes.

    3. Water pipe direction: It is recommended that the water pipe go to the top is the safest. The main reason is that most of the waterway reconstruction is done by dark pipes, and the characteristic of water is that water flows to a lower place.

    If the pipeline goes underground, it is difficult to find the leakage in time once it occurs, and the leakage will only be found if the water overflows or the floor is deformed and leaks downstairs, and it is difficult to find the leakage because the water pipe is buried in the dark. At this time, the huge loss is irreparable, and even seriously affects the friendly neighborly relationship; If the water pipes go to the top, it may be more expensive to change the water, but as a long-term investment, it is worth it. Even if the water pipe goes to the top, even if the water leaks, it can be found in time, which is convenient for maintenance and the loss is small.

    Finally, it is worth mentioning that no matter how the bathroom decoration is, it is necessary for us to understand the common sense of bathroom decoration. I think that in order to effectively implement the precautions for bathroom decoration, we must have some toilet safety knowledge, so as to avoid accidents that should not be wild.

Related questions
16 answers2024-06-28

The sunken toilet should be filled with construction waste and light ceramsite. In the most understandable terms, his floor is about 40 centimeters lower than the floor of other bathrooms, and there is a pit in the bathroom, which needs to be filled in by ourselves. <> >>>More

8 answers2024-06-28

Sunken toilet:

It refers to the partial or overall sinking of the toilet structural layer from a certain height of the corresponding floor during the construction of the main body, so that the horizontal drainage pipe of the toilet is buried in it, and then backfilled with lightweight materials, and only one hole is required for the use of drainage risers in the structural structure. Drainage risers are reliably set in the corners of the walls, and can be covered with external curved partitions when the owners decorate. Above the backfill layer according to the standard practice of the bathroom ground to achieve the required building plane, not only to avoid mutual interference during maintenance and use, and the occupied area is very small, economical and practical, a single toilet increases the cost of 150 yuan (overall sinking), with a very good performance ratio. >>>More

22 answers2024-06-28

In traditional Chinese feng shui, the kitchen belongs to fire and the bathroom belongs to water, these two positions are very important in feng shui, and the following aspects should be noted: >>>More

27 answers2024-06-28

Now that many owners have done this, it must be a little useful, and it will be very beautiful on the outside, and it will look more spacious at a glance. When you go to the toilet, when you flush the toilet, the sound will also be low! >>>More

19 answers2024-06-28

When we buy a house, we will look at a lot of house types, and we will also learn in the process of ** that some houses have sunken bathrooms, and most of the bathrooms are sunk, and only a very small part of the bathrooms are not sunk, what is the reason for this? This is because when the developer built the house, he used two different drainage methods, the sunken bathroom, which is called the same floor drainage. >>>More