-
Blood glucose meter is a very effective monitoring measure for monitoring blood sugar in the process of type 2 diabetes in the clinic, and the conventional blood glucose meter is divided into a blood glucose meter machine host and a test strip for blood glucose monitoring, and the test strip is mainly a process of using chip technology to convert glucose in plasma into finger blood glucose through glucose oxidation method. During the use of the blood glucose meter, the patient needs to be cleaned and disinfected, and the finger should be pricked with a blood collection needle after disinfecting the finger, and it is recommended to squeeze out the first drop of blood and place the second drop of blood on the test strip for measuring blood glucose. The test strip can automatically display the current blood glucose level according to different types of blood glucose meters and different time points.
During the use of the blood glucose meter, it is necessary to pay attention to the preservation of the test strip, pay attention to the humidity, temperature and expiration date, and it is recommended to go to the appropriate manufacturer or hospital for quality control and calibration after using it for a period of time.
The use of a blood glucose meter can be roughly divided into the following steps:1Turn on the power.
Some of them are directly pressed on the power switch, and some blood glucose meters are automatically turned on after being inserted directly into the test strip. 2.Adjust the correction code.
Some blood glucose meters need to adjust the correction code, and the correction code of the blood glucose meter needs to be consistent with the correction code marked on the test strip. There are some blood glucose meters that are free of adjustment codes. 3.
Blood collection, blood sucking, and try to choose the little finger and ring finger for blood collection, because this can reduce the chance of infection and reduce pain. When the blood glucose meter shows the blood drop mark, the blood droplet is close to the blood drop groove of the test strip, and the test strip blood drop groove sucks the blood into the test strip through the action of siphoning. 4.
Display the results. After sucking blood, the blood glucose meter shows a countdown, and most blood glucose meters show a blood glucose value within 30 seconds, after the countdown ends. 5.
Complete the test, remove the test strip, record the blood glucose value, some blood glucose meters need to be turned off, and some will automatically shut down after pulling out the test strip.
-
Device Name: Xunying Blood Glucose Meter (Trade Name: Oakmi).
Manufacturer: Xunying Optoelectronics Co., Ltd. ****.
Scope of application: The use of electrochemical biosensing technology is only suitable for the quantitative detection of glucose concentration in fresh capillary whole blood at the fingertip, and cannot be used for diabetes diagnosis or detection of neonatal blood. For in vitro diagnostic use only.
Product Description: The use of electrochemical biosensing technology is only suitable for the quantitative detection of fresh capillary size of finger tips and other blood collection sites (palm, forearm, upper arm, calf and thigh).
How to use: The first step: turn on the power, part of it is to press the power switch directly, and part of it is directly inserted into the test strip to automatically turn on. Step 2: Encoding adjustments. The code of the blood glucose meter.
Precautions: 1. The blood glucose meter is only used for blood measurement; 2. Do not place it in direct sunlight or high temperature and humidity places, do not drop the machine to the ground and avoid collision, please.
-
1. Take out the blood glucose meter, blood collection pen, blood collection needle, and test strip bucket, and put them on a clean desktop, and there should be no electronic devices such as televisions, mobile phones, and microwave ovens near to prevent interference. After washing or disinfecting your hands with warm water, you must wait for a completely clean test. Take out the blood collection pen and install the blood collection needle, and pay attention to the smaller the number, the shallower the piercing.
Pull the lance spring on gear. The first time you use it, you can adjust it to the middle gear first, and the next time you adjust the depth appropriately according to the actual situation.
2. Open the test strip bucket and take out the test strip, pay attention to cover the bucket lid immediately after taking out the collapse, and do not expose the air for a long time. Insert the test strip into the blood glucose meter, and the fingers should not pinch the blood suction port and plug during the process of taking and inserting the test strip, as the finger temperature will affect the result. If the blood glucose test strip needs to be corrected**, the ** displayed by the blood glucose meter must be consistent with the test strip**, and the results are inaccurate when inconsistent.
-
You can search online and you can see it, and the following ** is what I saw when I bought it online before**.
-
A bottle of 25 tablets is quite cost-effective.
-
I bought it in a bottle, a bottle of 25 tablets, I don't know if there is any other packaging.
-
Go to the market where batteries are sold, there are all kinds of batteries, take the blood glucose meter to open the back cover, take out the battery, buy the same button battery and replace it:
-
Open the lid on the back of the machine, take out the old batteries inside, and see if there are any batteries of the same size at a nearby convenience store, or contact the seller to send a few.
-
If you want to change the battery, you have to disassemble the entire blood glucose meter, and then there is a battery position inside, take the battery off and replace it again.
-
It seems that there is a cover on the back of the blood glucose meter that can be removed, and you can replace it with a new battery by opening it.
-
Open the battery cover at the back and take out the battery, and then buy the same button battery at the supermarket.
-
Just take your old battery to the store and show it to the owner, and you can buy it.
-
Take off the old battery and take it to a store to see if it is sold.
-
That's right, this is a listed company brand produced by European Technology Taiwan, which is very well-known and is one of the top ten brands.
-
Yes is one of the top 10 in the world.
-
How to use Omron blood glucose meter: Wash thoroughly and dry your hands. Warm and massage fingers to increase circulation.
Hang your arm down briefly to allow blood to flow to your fingertips. Use your thumb to hold the key interphalangeal joint to be collected, and then use a blood collection pen to puncture the fingertip side**, and do not squeeze it after pricking the skin, so as to avoid the tissue fluid mixing into the blood sample, resulting in deviation of the test results.
Put the blood droplets on your finger close to the blood collection port of the test strip, confirm that the blood drop symbol appears on the display screen, and then touch the blood collection port of the test strip, and when the blood collection window is full, the blood glucose meter will start to measure, and the measurement value will be displayed after 5 seconds. Pull the test strip out of the blood glucose meter, and the blood glucose meter will automatically turn off. Please dispose of the used test strips properly.
Correction method of Omron blood glucose meter: 1. Insert the test strip directly together in the shutdown state, the screen displays the current correction code, and the blood drop symbol flashes. 2. Press the C button once, change the correction code once, and find the same correction code as on the test strip.
3. Press the button to store the current correction code, and the blood symbol will be re-flashed and the table correction code is set successfully.
At present, the blood glucose often used in hospitals is Roche or Johnson & Johnson's blood glucose meter, both of which are foreign and relatively accurate. However, you can also choose a domestic blood glucose meter, and the accuracy of the domestic blood glucose meter is also okay. Whether you choose a domestic or imported blood glucose meter, it needs to be calibrated regularly. >>>More
The silicon-based continuous blood glucose meter is very simple and easy to use, this blood glucose meter does not need to prick your fingers, there is no pain when you wear it, if you need to measure blood sugar for a long time, this blood glucose meter must give it a try. It is relatively intelligent and has many functions, such as automatic blood glucose measurement for 14 consecutive days, blood glucose data synchronization mobile phone, reminders for abnormal blood sugar, and daily analysis of blood sugar generation data, etc., which are all very useful functions. And it's waterproof, so you don't have to take it off when swimming or bathing, so it's worth a try.
If your blood sugar is high, buying one is a must. This makes it easy to monitor your blood sugar levels, especially on a date as complicated as pregnancy. >>>More
The Roche Excellence Blood Glucose Meter shows E-5 after inserting the test strip >>>More
Hello, may I ask what you are comparing with above, if it is compared with the blood glucose meter in the hospital, it is not comparable. If it is higher than that of a biochemical machine, what is the blood sugar concentration you are measuring? According to the national standard, more than 95% of the test results meet the 75mg dl (the deviation in parentheses is within 15mg dl (when the domestic use unit is below, and the deviation is allowed within 20% when it is higher than 75mg dl). >>>More